aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/hwmon/pmbus/Kconfig
blob: 4b26f51920ba8aa291918af49eb9bf4558a482f5 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
#
# PMBus chip drivers configuration
#

menuconfig PMBUS
	tristate "PMBus support"
	depends on I2C && EXPERIMENTAL
	default n
	help
	  Say yes here if you want to enable PMBus support.

	  This driver can also be built as a module. If so, the module will
	  be called pmbus_core.

if PMBUS

config SENSORS_PMBUS
	tristate "Generic PMBus devices"
	default y
	help
	  If you say yes here you get hardware monitoring support for generic
	  PMBus devices, including but not limited to ADP4000, BMR450, BMR451,
	  BMR453, BMR454, NCP4200, and NCP4208.

	  This driver can also be built as a module. If so, the module will
	  be called pmbus.

config SENSORS_ADM1275
	tristate "Analog Devices ADM1275 and compatibles"
	default n
	help
	  If you say yes here you get hardware monitoring support for Analog
	  Devices ADM1275 and ADM1276 Hot-Swap Controller and Digital Power
	  Monitor.

	  This driver can also be built as a module. If so, the module will
	  be called adm1275.

config SENSORS_LM25066
	tristate "National Semiconductor LM25066 and compatibles"
	default n
	help
	  If you say yes here you get hardware monitoring support for National
	  Semiconductor LM25066, LM5064, and LM5066.

	  This driver can also be built as a module. If so, the module will
	  be called lm25066.

config SENSORS_LTC2978
	tristate "Linear Technologies LTC2978 and LTC3880"
	default n
	help
	  If you say yes here you get hardware monitoring support for Linear
	  Technology LTC2978 and LTC3880.

	  This driver can also be built as a module. If so, the module will
	  be called ltc2978.

config SENSORS_MAX16064
	tristate "Maxim MAX16064"
	default n
	help
	  If you say yes here you get hardware monitoring support for Maxim
	  MAX16064.

	  This driver can also be built as a module. If so, the module will
	  be called max16064.

config SENSORS_MAX34440
	tristate "Maxim MAX34440/MAX34441"
	default n
	help
	  If you say yes here you get hardware monitoring support for Maxim
	  MAX34440 and MAX34441.

	  This driver can also be built as a module. If so, the module will
	  be called max34440.

config SENSORS_MAX8688
	tristate "Maxim MAX8688"
	default n
	help
	  If you say yes here you get hardware monitoring support for Maxim
	  MAX8688.

	  This driver can also be built as a module. If so, the module will
	  be called max8688.

config SENSORS_UCD9000
	tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
	default n
	help
	  If you say yes here you get hardware monitoring support for TI
	  UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
	  Controllers.

	  This driver can also be built as a module. If so, the module will
	  be called ucd9000.

config SENSORS_UCD9200
	tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
	default n
	help
	  If you say yes here you get hardware monitoring support for TI
	  UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
	  Digital PWM System Controllers.

	  This driver can also be built as a module. If so, the module will
	  be called ucd9200.

config SENSORS_ZL6100
	tristate "Intersil ZL6100 and compatibles"
	default n
	help
	  If you say yes here you get hardware monitoring support for Intersil
	  ZL2004, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, and ZL6105 Digital
	  DC/DC Controllers.

	  This driver can also be built as a module. If so, the module will
	  be called zl6100.

endif # PMBUS