diff options
Diffstat (limited to 'include/linux/cpu_cooling.h')
| -rw-r--r-- | include/linux/cpu_cooling.h | 58 |
1 files changed, 58 insertions, 0 deletions
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h new file mode 100644 index 000000000000..851530128e65 --- /dev/null +++ b/include/linux/cpu_cooling.h | |||
| @@ -0,0 +1,58 @@ | |||
| 1 | /* | ||
| 2 | * linux/include/linux/cpu_cooling.h | ||
| 3 | * | ||
| 4 | * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) | ||
| 5 | * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org> | ||
| 6 | * | ||
| 7 | * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | ||
| 8 | * This program is free software; you can redistribute it and/or modify | ||
| 9 | * it under the terms of the GNU General Public License as published by | ||
| 10 | * the Free Software Foundation; version 2 of the License. | ||
| 11 | * | ||
| 12 | * This program is distributed in the hope that it will be useful, but | ||
| 13 | * WITHOUT ANY WARRANTY; without even the implied warranty of | ||
| 14 | * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU | ||
| 15 | * General Public License for more details. | ||
| 16 | * | ||
| 17 | * You should have received a copy of the GNU General Public License along | ||
| 18 | * with this program; if not, write to the Free Software Foundation, Inc., | ||
| 19 | * 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA. | ||
| 20 | * | ||
| 21 | * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | ||
| 22 | */ | ||
| 23 | |||
| 24 | #ifndef __CPU_COOLING_H__ | ||
| 25 | #define __CPU_COOLING_H__ | ||
| 26 | |||
| 27 | #include <linux/thermal.h> | ||
| 28 | |||
| 29 | #define CPUFREQ_COOLING_START 0 | ||
| 30 | #define CPUFREQ_COOLING_STOP 1 | ||
| 31 | |||
| 32 | #ifdef CONFIG_CPU_THERMAL | ||
| 33 | /** | ||
| 34 | * cpufreq_cooling_register - function to create cpufreq cooling device. | ||
| 35 | * @clip_cpus: cpumask of cpus where the frequency constraints will happen | ||
| 36 | */ | ||
| 37 | struct thermal_cooling_device *cpufreq_cooling_register( | ||
| 38 | struct cpumask *clip_cpus); | ||
| 39 | |||
| 40 | /** | ||
| 41 | * cpufreq_cooling_unregister - function to remove cpufreq cooling device. | ||
| 42 | * @cdev: thermal cooling device pointer. | ||
| 43 | */ | ||
| 44 | void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev); | ||
| 45 | #else /* !CONFIG_CPU_THERMAL */ | ||
| 46 | static inline struct thermal_cooling_device *cpufreq_cooling_register( | ||
| 47 | struct cpumask *clip_cpus) | ||
| 48 | { | ||
| 49 | return NULL; | ||
| 50 | } | ||
| 51 | static inline void cpufreq_cooling_unregister( | ||
| 52 | struct thermal_cooling_device *cdev) | ||
| 53 | { | ||
| 54 | return; | ||
| 55 | } | ||
| 56 | #endif /* CONFIG_CPU_THERMAL */ | ||
| 57 | |||
| 58 | #endif /* __CPU_COOLING_H__ */ | ||
