aboutsummaryrefslogtreecommitdiffstats
path: root/include/linux
diff options
context:
space:
mode:
authorPaul Fertser <fercerpav@gmail.com>2009-11-04 16:24:57 -0500
committerAnton Vorontsov <cbouatmailru@gmail.com>2009-11-15 19:31:17 -0500
commite98c73a24f33d6f54402f5cef2e7bf282d1d1fcc (patch)
tree8c11a30ac8d3d8f8f96bee76d8bac40c7d6b8f43 /include/linux
parent31b4ff06e01a9a98a8e6ae6e8c42213648eec1d1 (diff)
pcf50633: Get rid of charging restart software auto-triggering
After reaching Battery Full condition MBC state machine switches back into charging mode when the battery voltage falls below 96% of a battery float voltage. The voltage drop in Li-Ion batteries is marginal (1-2%) till about 80% of its capacity - which means, after a BATFULL, charging won't be restarted until 75-80%. That is a desired behaviour recommended by battery manufacturers, don't mess with it. Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Diffstat (limited to 'include/linux')
-rw-r--r--include/linux/mfd/pcf50633/core.h2
1 files changed, 0 insertions, 2 deletions
diff --git a/include/linux/mfd/pcf50633/core.h b/include/linux/mfd/pcf50633/core.h
index 09af8fdfbb5d..46df7f053c29 100644
--- a/include/linux/mfd/pcf50633/core.h
+++ b/include/linux/mfd/pcf50633/core.h
@@ -29,8 +29,6 @@ struct pcf50633_platform_data {
29 char **batteries; 29 char **batteries;
30 int num_batteries; 30 int num_batteries;
31 31
32 int charging_restart_interval;
33
34 /* 32 /*
35 * Should be set accordingly to the reference resistor used, see 33 * Should be set accordingly to the reference resistor used, see
36 * I_{ch(ref)} charger reference current in the pcf50633 User 34 * I_{ch(ref)} charger reference current in the pcf50633 User