regulator: ti-abb: Fix bias voltage glitch in transition to bypass mode
As documented in Application Note SWPA117 v2.1(NDA), LDO override has a requirement that when switching from Bias active + override active mode(FBB/RBB) to Bypass(nominal) mode, LDO reset must be performed *after* LDO transitions to Bypass(nominal) mode. The same rule in reverse applies when switching from a ABB bypass mode to ABB enabled - LDO override *must* be performed prior to transition to required ABB mode, if we do not do that, the same glitch takes place. Currently while transitioning to ABB bypass, we reset the LDO overide prior to the transition which causes a few milliseconds where ABB LDO voltage could go all the way to 800mV(based on SoC process node), during this period, the delta voltage between VDD rail and VBB rail could cause the system to improperly function. Signed-off-by: Nishanth Menon <nm@ti.com> Signed-off-by: Mark Brown <broonie@linaro.org> Cc: stable@vger.kernel.org
Diffstat (limited to 'drivers/regulator/ti-abb-regulator.c')
-rw-r--r--drivers/regulator/ti-abb-regulator.c16
1 files changed, 14 insertions, 2 deletions
diff --git a/drivers/regulator/ti-abb-regulator.c b/drivers/regulator/ti-abb-regulator.c
index d8e3e1262bc2..20c271d49dcb 100644
--- a/drivers/regulator/ti-abb-regulator.c
+++ b/drivers/regulator/ti-abb-regulator.c
@@ -279,8 +279,12 @@ static int ti_abb_set_opp(struct regulator_dev *rdev, struct ti_abb *abb,
279 ti_abb_rmw(regs->opp_sel_mask, info->opp_sel, regs->control_reg, 279 ti_abb_rmw(regs->opp_sel_mask, info->opp_sel, regs->control_reg,
280 abb->base); 280 abb->base);
281 281
282 /* program LDO VBB vset override if needed */ 282 /*
283 if (abb->ldo_base) 283 * program LDO VBB vset override if needed for !bypass mode
284 * XXX: Do not switch sequence - for !bypass, LDO override reset *must*
285 * be performed *before* switch to bias mode else VBB glitches.
286 */
287 if (abb->ldo_base && info->opp_sel != TI_ABB_NOMINAL_OPP)
284 ti_abb_program_ldovbb(dev, abb, info); 288 ti_abb_program_ldovbb(dev, abb, info);
285 289
286 /* Initiate ABB ldo change */ 290 /* Initiate ABB ldo change */
@@ -295,6 +299,14 @@ static int ti_abb_set_opp(struct regulator_dev *rdev, struct ti_abb *abb,
295 if (ret) 299 if (ret)
296 goto out; 300 goto out;
297 301
302 /*
303 * Reset LDO VBB vset override bypass mode
304 * XXX: Do not switch sequence - for bypass, LDO override reset *must*
305 * be performed *after* switch to bypass else VBB glitches.
306 */
307 if (abb->ldo_base && info->opp_sel == TI_ABB_NOMINAL_OPP)
308 ti_abb_program_ldovbb(dev, abb, info);
309
298out: 310out:
299 return ret; 311 return ret;
300} 312}