aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/sk98lin/skge.c
diff options
context:
space:
mode:
authorStephen Hemminger <shemminger@osdl.org>2005-09-13 13:02:44 -0400
committerJeff Garzik <jgarzik@pobox.com>2005-09-14 08:02:41 -0400
commit9734c3fc89e5e2b5c132ed47fe096711eff2c092 (patch)
treed5d30f4c2d5bd245d4a34b9c769fac8d0073a5a7 /drivers/net/sk98lin/skge.c
parentd8ac10639b6a1ed900efbee38c18baaca31e64dc (diff)
[PATCH] sk98lin: remove PCI id info for cards for conflicting devices
Fix PCI device id issues with sk98lin driver. 1. DLINK 530-T card has no Vital Product Data (VPD) area so the sk98lin driver won't work. (skge does however) 2. Remove commented out Yukon2 stuff 3. Restrict Linksys card to revisions that don't conflict with r8169 version. Signed-off-by: Stephen Hemminger <shemminger@osdl.org> Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
Diffstat (limited to 'drivers/net/sk98lin/skge.c')
-rw-r--r--drivers/net/sk98lin/skge.c12
1 files changed, 5 insertions, 7 deletions
diff --git a/drivers/net/sk98lin/skge.c b/drivers/net/sk98lin/skge.c
index 6ee4771addf1..2e72d79a143c 100644
--- a/drivers/net/sk98lin/skge.c
+++ b/drivers/net/sk98lin/skge.c
@@ -5216,17 +5216,15 @@ static struct pci_device_id skge_pci_tbl[] = {
5216 { PCI_VENDOR_ID_3COM, 0x80eb, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5216 { PCI_VENDOR_ID_3COM, 0x80eb, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5217 { PCI_VENDOR_ID_SYSKONNECT, 0x4300, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5217 { PCI_VENDOR_ID_SYSKONNECT, 0x4300, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5218 { PCI_VENDOR_ID_SYSKONNECT, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5218 { PCI_VENDOR_ID_SYSKONNECT, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5219 { PCI_VENDOR_ID_DLINK, 0x4c00, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5219/* DLink card does not have valid VPD so this driver gags
5220 * { PCI_VENDOR_ID_DLINK, 0x4c00, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5221 */
5220 { PCI_VENDOR_ID_MARVELL, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5222 { PCI_VENDOR_ID_MARVELL, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5221#if 0 /* don't handle Yukon2 cards at the moment -- mlindner@syskonnect.de */
5222 { PCI_VENDOR_ID_MARVELL, 0x4360, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5223 { PCI_VENDOR_ID_MARVELL, 0x4361, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5224#endif
5225 { PCI_VENDOR_ID_MARVELL, 0x5005, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5223 { PCI_VENDOR_ID_MARVELL, 0x5005, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5226 { PCI_VENDOR_ID_CNET, 0x434e, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5224 { PCI_VENDOR_ID_CNET, 0x434e, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5227 { PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5225 { PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, 0x0015, },
5228 { PCI_VENDOR_ID_LINKSYS, 0x1064, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 }, 5226 { PCI_VENDOR_ID_LINKSYS, 0x1064, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
5229 { 0, } 5227 { 0 }
5230}; 5228};
5231 5229
5232MODULE_DEVICE_TABLE(pci, skge_pci_tbl); 5230MODULE_DEVICE_TABLE(pci, skge_pci_tbl);