diff options
author | Ben Dooks <ben-linux@fluff.org> | 2007-07-22 11:07:09 -0400 |
---|---|---|
committer | Russell King <rmk+kernel@arm.linux.org.uk> | 2007-07-22 11:44:26 -0400 |
commit | d58153d86589b6bba2dd19f4c178252f8cf2ed4f (patch) | |
tree | 08db984919265e58408199f114d026c184063819 /arch/arm/plat-s3c24xx/Kconfig | |
parent | 531b617c71e780b14af5931428e0611f930c2134 (diff) |
[ARM] 4509/1: S3C: Create initial arch/arm/plat-s3c
Create the initial arch/arm/plat-s3c directory and start
linking it into the arch/arm build heirarchy ready to
receive the generic parts of the S3C24XX support to be
used when adding S3C6400 devices.
Signed-off-by: Ben Dooks <ben-linux@fluff.org>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
Diffstat (limited to 'arch/arm/plat-s3c24xx/Kconfig')
-rw-r--r-- | arch/arm/plat-s3c24xx/Kconfig | 60 |
1 files changed, 1 insertions, 59 deletions
diff --git a/arch/arm/plat-s3c24xx/Kconfig b/arch/arm/plat-s3c24xx/Kconfig index b972f36d547c..b66fb3c4e228 100644 --- a/arch/arm/plat-s3c24xx/Kconfig +++ b/arch/arm/plat-s3c24xx/Kconfig | |||
@@ -10,7 +10,7 @@ config PLAT_S3C24XX | |||
10 | default y if ARCH_S3C2410 | 10 | default y if ARCH_S3C2410 |
11 | select NO_IOPORT | 11 | select NO_IOPORT |
12 | help | 12 | help |
13 | Base platform code for any Samsung S3C device | 13 | Base platform code for any Samsung S3C24XX device |
14 | 14 | ||
15 | if PLAT_S3C24XX | 15 | if PLAT_S3C24XX |
16 | 16 | ||
@@ -26,64 +26,6 @@ config PM_SIMTEC | |||
26 | Common power management code for systems that are | 26 | Common power management code for systems that are |
27 | compatible with the Simtec style of power management | 27 | compatible with the Simtec style of power management |
28 | 28 | ||
29 | config S3C2410_BOOT_WATCHDOG | ||
30 | bool "S3C2410 Initialisation watchdog" | ||
31 | depends on ARCH_S3C2410 && S3C2410_WATCHDOG | ||
32 | help | ||
33 | Say y to enable the watchdog during the kernel decompression | ||
34 | stage. If the kernel fails to uncompress, then the watchdog | ||
35 | will trigger a reset and the system should restart. | ||
36 | |||
37 | config S3C2410_BOOT_ERROR_RESET | ||
38 | bool "S3C2410 Reboot on decompression error" | ||
39 | depends on ARCH_S3C2410 | ||
40 | help | ||
41 | Say y here to use the watchdog to reset the system if the | ||
42 | kernel decompressor detects an error during decompression. | ||
43 | |||
44 | config S3C2410_PM_DEBUG | ||
45 | bool "S3C2410 PM Suspend debug" | ||
46 | depends on ARCH_S3C2410 && PM | ||
47 | help | ||
48 | Say Y here if you want verbose debugging from the PM Suspend and | ||
49 | Resume code. See <file:Documentation/arm/Samsung-S3C24XX/Suspend.txt> | ||
50 | for more information. | ||
51 | |||
52 | config S3C2410_PM_CHECK | ||
53 | bool "S3C2410 PM Suspend Memory CRC" | ||
54 | depends on ARCH_S3C2410 && PM && CRC32 | ||
55 | help | ||
56 | Enable the PM code's memory area checksum over sleep. This option | ||
57 | will generate CRCs of all blocks of memory, and store them before | ||
58 | going to sleep. The blocks are then checked on resume for any | ||
59 | errors. | ||
60 | |||
61 | Note, this can take several seconds depending on memory size | ||
62 | and CPU speed. | ||
63 | |||
64 | See <file:Documentation/arm/Samsung-S3C24XX/Suspend.txt> | ||
65 | |||
66 | config S3C2410_PM_CHECK_CHUNKSIZE | ||
67 | int "S3C2410 PM Suspend CRC Chunksize (KiB)" | ||
68 | depends on ARCH_S3C2410 && PM && S3C2410_PM_CHECK | ||
69 | default 64 | ||
70 | help | ||
71 | Set the chunksize in Kilobytes of the CRC for checking memory | ||
72 | corruption over suspend and resume. A smaller value will mean that | ||
73 | the CRC data block will take more memory, but wil identify any | ||
74 | faults with better precision. | ||
75 | |||
76 | See <file:Documentation/arm/Samsung-S3C24XX/Suspend.txt> | ||
77 | |||
78 | config S3C2410_LOWLEVEL_UART_PORT | ||
79 | int "S3C2410 UART to use for low-level messages" | ||
80 | default 0 | ||
81 | help | ||
82 | Choice of which UART port to use for the low-level messages, | ||
83 | such as the `Uncompressing...` at start time. The value of | ||
84 | this configuration should be between zero and two. The port | ||
85 | must have been initialised by the boot-loader before use. | ||
86 | |||
87 | config S3C2410_DMA | 29 | config S3C2410_DMA |
88 | bool "S3C2410 DMA support" | 30 | bool "S3C2410 DMA support" |
89 | depends on ARCH_S3C2410 | 31 | depends on ARCH_S3C2410 |