diff options
author | Steven King <sfking@fdwdc.com> | 2010-05-27 13:58:56 -0400 |
---|---|---|
committer | Jean Delvare <khali@linux-fr.org> | 2010-05-27 13:58:56 -0400 |
commit | beb1b6bbf2b448b97b9611200eb4b5a555336c60 (patch) | |
tree | ff20c6fe10e2ef0f29e5fe0f21caf1fcff5236d6 /Documentation/hwmon | |
parent | dac6831e67e90d1cee430a66e7390e753c20d835 (diff) |
hwmon: Driver for TI TMP102 temperature sensor
Driver for the TI TMP102.
The TI TMP102 is similar to the LM75. It differs from the LM75 by
having a 16-bit conf register and the temp registers have a minimum
resolution of 12 bits; the extended conf register can select 13-bit
resolution (which this driver does) and also change the update rate
(which this driver currently doesn't use).
[JD: Fix tmp102_exit tag, must be __exit, not __init.]
Signed-off-by: Steven King <sfking@fdwdc.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/tmp102 | 27 |
1 files changed, 27 insertions, 0 deletions
diff --git a/Documentation/hwmon/tmp102 b/Documentation/hwmon/tmp102 new file mode 100644 index 000000000000..239dded8539f --- /dev/null +++ b/Documentation/hwmon/tmp102 | |||
@@ -0,0 +1,27 @@ | |||
1 | Kernel driver tmp102 | ||
2 | ==================== | ||
3 | |||
4 | Supported chips: | ||
5 | * Texas Instruments TMP102 | ||
6 | Prefix: 'tmp102' | ||
7 | Addresses scanned: I2C 0x48 0x49 0x4a 0x4b | ||
8 | Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html | ||
9 | |||
10 | Author: | ||
11 | Steven King <sfking@fdwdc.com> | ||
12 | |||
13 | Description | ||
14 | ----------- | ||
15 | |||
16 | The Texas Instruments TMP102 implements one temperature sensor. Limits can be | ||
17 | set through the Overtemperature Shutdown register and Hysteresis register. The | ||
18 | sensor is accurate to 0.5 degrees over the range of -25 to +85 C, and to 1.0 | ||
19 | degrees from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The | ||
20 | operating temperature has a minimum of -55 C and a maximum of +150 C. | ||
21 | |||
22 | The TMP102 has a programmable update rate that can select between 8, 4, 1, and | ||
23 | 0.5 Hz. (Currently the driver only supports the default of 4 Hz). | ||
24 | |||
25 | The driver provides the common sysfs-interface for temperatures (see | ||
26 | /Documentation/hwmon/sysfs-interface under Temperatures). | ||