diff options
author | Jordan Crouse <jordan.crouse@amd.com> | 2009-01-15 16:27:47 -0500 |
---|---|---|
committer | Jean Delvare <khali@linux-fr.org> | 2009-01-15 16:27:47 -0500 |
commit | 1c301fc5394f7e1aa4c201e6e03d55d9c08b3bdf (patch) | |
tree | 579d27b572c965a377a9a8da7ff16d7f9febfe1b /Documentation/hwmon/adt7475 | |
parent | 76ff08da34196cfa308fcd3552bb9ea20888e745 (diff) |
hwmon: Add a driver for the ADT7475 hardware monitoring chip
Hwmon driver for the ADT7475 chip.
Signed-off-by: Jordan Crouse <jordan.crouse@amd.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon/adt7475')
-rw-r--r-- | Documentation/hwmon/adt7475 | 87 |
1 files changed, 87 insertions, 0 deletions
diff --git a/Documentation/hwmon/adt7475 b/Documentation/hwmon/adt7475 new file mode 100644 index 000000000000..a2b1abec850e --- /dev/null +++ b/Documentation/hwmon/adt7475 | |||
@@ -0,0 +1,87 @@ | |||
1 | This describes the interface for the ADT7475 driver: | ||
2 | |||
3 | (there are 4 fans, numbered fan1 to fan4): | ||
4 | |||
5 | fanX_input Read the current speed of the fan (in RPMs) | ||
6 | fanX_min Read/write the minimum speed of the fan. Dropping | ||
7 | below this sets an alarm. | ||
8 | |||
9 | (there are three PWMs, numbered pwm1 to pwm3): | ||
10 | |||
11 | pwmX Read/write the current duty cycle of the PWM. Writes | ||
12 | only have effect when auto mode is turned off (see | ||
13 | below). Range is 0 - 255. | ||
14 | |||
15 | pwmX_enable Fan speed control method: | ||
16 | |||
17 | 0 - No control (fan at full speed) | ||
18 | 1 - Manual fan speed control (using pwm[1-*]) | ||
19 | 2 - Automatic fan speed control | ||
20 | |||
21 | pwmX_auto_channels_temp Select which channels affect this PWM | ||
22 | |||
23 | 1 - TEMP1 controls PWM | ||
24 | 2 - TEMP2 controls PWM | ||
25 | 4 - TEMP3 controls PWM | ||
26 | 6 - TEMP2 and TEMP3 control PWM | ||
27 | 7 - All three inputs control PWM | ||
28 | |||
29 | pwmX_freq Read/write the PWM frequency in Hz. The number | ||
30 | should be one of the following: | ||
31 | |||
32 | 11 Hz | ||
33 | 14 Hz | ||
34 | 22 Hz | ||
35 | 29 Hz | ||
36 | 35 Hz | ||
37 | 44 Hz | ||
38 | 58 Hz | ||
39 | 88 Hz | ||
40 | |||
41 | pwmX_auto_point1_pwm Read/write the minimum PWM duty cycle in automatic mode | ||
42 | |||
43 | pwmX_auto_point2_pwm Read/write the maximum PWM duty cycle in automatic mode | ||
44 | |||
45 | (there are three temperature settings numbered temp1 to temp3): | ||
46 | |||
47 | tempX_input Read the current temperature. The value is in milli | ||
48 | degrees of Celsius. | ||
49 | |||
50 | tempX_max Read/write the upper temperature limit - exceeding this | ||
51 | will cause an alarm. | ||
52 | |||
53 | tempX_min Read/write the lower temperature limit - exceeding this | ||
54 | will cause an alarm. | ||
55 | |||
56 | tempX_offset Read/write the temperature adjustment offset | ||
57 | |||
58 | tempX_crit Read/write the THERM limit for remote1. | ||
59 | |||
60 | tempX_crit_hyst Set the temperature value below crit where the | ||
61 | fans will stay on - this helps drive the temperature | ||
62 | low enough so it doesn't stay near the edge and | ||
63 | cause THERM to keep tripping. | ||
64 | |||
65 | tempX_auto_point1_temp Read/write the minimum temperature where the fans will | ||
66 | turn on in automatic mode. | ||
67 | |||
68 | tempX_auto_point2_temp Read/write the maximum temperature over which the fans | ||
69 | will run in automatic mode. tempX_auto_point1_temp | ||
70 | and tempX_auto_point2_temp together define the | ||
71 | range of automatic control. | ||
72 | |||
73 | tempX_alarm Read a 1 if the max/min alarm is set | ||
74 | tempX_fault Read a 1 if either temp1 or temp3 diode has a fault | ||
75 | |||
76 | (There are two voltage settings, in1 and in2): | ||
77 | |||
78 | inX_input Read the current voltage on VCC. Value is in | ||
79 | millivolts. | ||
80 | |||
81 | inX_min read/write the minimum voltage limit. | ||
82 | Dropping below this causes an alarm. | ||
83 | |||
84 | inX_max read/write the maximum voltage limit. | ||
85 | Exceeding this causes an alarm. | ||
86 | |||
87 | inX_alarm Read a 1 if the max/min alarm is set. | ||