Diffstat (limited to 'Documentation/devicetree/bindings/thermal')
-rw-r--r-- | Documentation/devicetree/bindings/thermal/armada-thermal.txt | 12 | ||||
-rw-r--r-- | Documentation/devicetree/bindings/thermal/exynos-thermal.txt | 50 |
2 files changed, 58 insertions, 4 deletions
diff --git a/Documentation/devicetree/bindings/thermal/armada-thermal.txt b/Documentation/devicetree/bindings/thermal/armada-thermal.txt index fff93d5f92de..4cf024929a3f 100644 --- a/Documentation/devicetree/bindings/thermal/armada-thermal.txt +++ b/Documentation/devicetree/bindings/thermal/armada-thermal.txt | |||
@@ -1,11 +1,21 @@ | |||
1 | * Marvell Armada 370/XP thermal management | 1 | * Marvell Armada 370/375/380/XP thermal management |
2 | 2 | ||
3 | Required properties: | 3 | Required properties: |
4 | 4 | ||
5 | - compatible: Should be set to one of the following: | 5 | - compatible: Should be set to one of the following: |
6 | marvell,armada370-thermal | 6 | marvell,armada370-thermal |
7 | marvell,armada375-thermal | ||
8 | marvell,armada375-z1-thermal | ||
9 | marvell,armada380-thermal | ||
7 | marvell,armadaxp-thermal | 10 | marvell,armadaxp-thermal |
8 | 11 | ||
12 | Note: As the name suggests, "marvell,armada375-z1-thermal" | ||
13 | applies for the SoC Z1 stepping only. On such stepping | ||
14 | some quirks need to be done and the register offset differs | ||
15 | from the one in the A0 stepping. | ||
16 | The operating system may auto-detect the SoC stepping and | ||
17 | update the compatible and register offsets at runtime. | ||
18 | |||
9 | - reg: Device's register space. | 19 | - reg: Device's register space. |
10 | Two entries are expected, see the examples below. | 20 | Two entries are expected, see the examples below. |
11 | The first one is required for the sensor register; | 21 | The first one is required for the sensor register; |
diff --git a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt b/Documentation/devicetree/bindings/thermal/exynos-thermal.txt index 284f5300fd8b..c94909215c07 100644 --- a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt +++ b/Documentation/devicetree/bindings/thermal/exynos-thermal.txt | |||
@@ -6,16 +6,35 @@ | |||
6 | "samsung,exynos4412-tmu" | 6 | "samsung,exynos4412-tmu" |
7 | "samsung,exynos4210-tmu" | 7 | "samsung,exynos4210-tmu" |
8 | "samsung,exynos5250-tmu" | 8 | "samsung,exynos5250-tmu" |
9 | "samsung,exynos5260-tmu" | ||
10 | "samsung,exynos5420-tmu" for TMU channel 0, 1 on Exynos5420 | ||
11 | "samsung,exynos5420-tmu-ext-triminfo" for TMU channels 2, 3 and 4 | ||
12 | Exynos5420 (Must pass triminfo base and triminfo clock) | ||
9 | "samsung,exynos5440-tmu" | 13 | "samsung,exynos5440-tmu" |
10 | - interrupt-parent : The phandle for the interrupt controller | 14 | - interrupt-parent : The phandle for the interrupt controller |
11 | - reg : Address range of the thermal registers. For soc's which has multiple | 15 | - reg : Address range of the thermal registers. For soc's which has multiple |
12 | instances of TMU and some registers are shared across all TMU's like | 16 | instances of TMU and some registers are shared across all TMU's like |
13 | interrupt related then 2 set of register has to supplied. First set | 17 | interrupt related then 2 set of register has to supplied. First set |
14 | belongs to each instance of TMU and second set belongs to common TMU | 18 | belongs to register set of TMU instance and second set belongs to |
15 | registers. | 19 | registers shared with the TMU instance. |
20 | |||
21 | NOTE: On Exynos5420, the TRIMINFO register is misplaced for TMU | ||
22 | channels 2, 3 and 4 | ||
23 | Use "samsung,exynos5420-tmu-ext-triminfo" in cases, there is a misplaced | ||
24 | register, also provide clock to access that base. | ||
25 | |||
26 | TRIMINFO at 0x1006c000 contains data for TMU channel 3 | ||
27 | TRIMINFO at 0x100a0000 contains data for TMU channel 4 | ||
28 | TRIMINFO at 0x10068000 contains data for TMU channel 2 | ||
29 | |||
16 | - interrupts : Should contain interrupt for thermal system | 30 | - interrupts : Should contain interrupt for thermal system |
17 | - clocks : The main clock for TMU device | 31 | - clocks : The main clocks for TMU device |
32 | -- 1. operational clock for TMU channel | ||
33 | -- 2. optional clock to access the shared registers of TMU channel | ||
18 | - clock-names : Thermal system clock name | 34 | - clock-names : Thermal system clock name |
35 | -- "tmu_apbif" operational clock for current TMU channel | ||
36 | -- "tmu_triminfo_apbif" clock to access the shared triminfo register | ||
37 | for current TMU channel | ||
19 | - vtmu-supply: This entry is optional and provides the regulator node supplying | 38 | - vtmu-supply: This entry is optional and provides the regulator node supplying |
20 | voltage to TMU. If needed this entry can be placed inside | 39 | voltage to TMU. If needed this entry can be placed inside |
21 | board/platform specific dts file. | 40 | board/platform specific dts file. |
@@ -43,6 +62,31 @@ Example 2): | |||
43 | clock-names = "tmu_apbif"; | 62 | clock-names = "tmu_apbif"; |
44 | }; | 63 | }; |
45 | 64 | ||
65 | Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register") | ||
66 | tmu_cpu2: tmu@10068000 { | ||
67 | compatible = "samsung,exynos5420-tmu-ext-triminfo"; | ||
68 | reg = <0x10068000 0x100>, <0x1006c000 0x4>; | ||
69 | interrupts = <0 184 0>; | ||
70 | clocks = <&clock 318>, <&clock 318>; | ||
71 | clock-names = "tmu_apbif", "tmu_triminfo_apbif"; | ||
72 | }; | ||
73 | |||
74 | tmu_cpu3: tmu@1006c000 { | ||
75 | compatible = "samsung,exynos5420-tmu-ext-triminfo"; | ||
76 | reg = <0x1006c000 0x100>, <0x100a0000 0x4>; | ||
77 | interrupts = <0 185 0>; | ||
78 | clocks = <&clock 318>, <&clock 319>; | ||
79 | clock-names = "tmu_apbif", "tmu_triminfo_apbif"; | ||
80 | }; | ||
81 | |||
82 | tmu_gpu: tmu@100a0000 { | ||
83 | compatible = "samsung,exynos5420-tmu-ext-triminfo"; | ||
84 | reg = <0x100a0000 0x100>, <0x10068000 0x4>; | ||
85 | interrupts = <0 215 0>; | ||
86 | clocks = <&clock 319>, <&clock 318>; | ||
87 | clock-names = "tmu_apbif", "tmu_triminfo_apbif"; | ||
88 | }; | ||
89 | |||
46 | Note: For multi-instance tmu each instance should have an alias correctly | 90 | Note: For multi-instance tmu each instance should have an alias correctly |
47 | numbered in "aliases" node. | 91 | numbered in "aliases" node. |
48 | 92 | ||