aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/power/charger-manager.txt
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/power/charger-manager.txt')
-rw-r--r--Documentation/power/charger-manager.txt16
1 files changed, 15 insertions, 1 deletions
diff --git a/Documentation/power/charger-manager.txt b/Documentation/power/charger-manager.txt
index 9b3863386e5..b4f7f4b23f6 100644
--- a/Documentation/power/charger-manager.txt
+++ b/Documentation/power/charger-manager.txt
@@ -50,6 +50,10 @@ Charger Manager supports the following:
50 restarts charging. This check is also performed while suspended by 50 restarts charging. This check is also performed while suspended by
51 setting wakeup time accordingly and using suspend_again. 51 setting wakeup time accordingly and using suspend_again.
52 52
53* Support for uevent-notify
54 With the charger-related events, the device sends
55 notification to users with UEVENT.
56
532. Global Charger-Manager Data related with suspend_again 572. Global Charger-Manager Data related with suspend_again
54======================================================== 58========================================================
55In order to setup Charger Manager with suspend-again feature 59In order to setup Charger Manager with suspend-again feature
@@ -174,7 +178,17 @@ bool measure_battery_temp;
174 the value of measure_battery_temp. 178 the value of measure_battery_temp.
175}; 179};
176 180
1775. Other Considerations 1815. Notify Charger-Manager of charger events: cm_notify_event()
182=========================================================
183If there is an charger event is required to notify
184Charger Manager, a charger device driver that triggers the event can call
185cm_notify_event(psy, type, msg) to notify the corresponding Charger Manager.
186In the function, psy is the charger driver's power_supply pointer, which is
187associated with Charger-Manager. The parameter "type"
188is the same as irq's type (enum cm_event_types). The event message "msg" is
189optional and is effective only if the event type is "UNDESCRIBED" or "OTHERS".
190
1916. Other Considerations
178======================= 192=======================
179 193
180At the charger/battery-related events such as battery-pulled-out, 194At the charger/battery-related events such as battery-pulled-out,