hwmon: (lm78) Add individual alarm files
Add individual alarm files to the lm78 driver, these are needed by the next version of libsensors. Signed-off-by: Jean Delvare <khali@linux-fr.org> Acked-by: Hans de Goede <j.w.r.degoede@hhs.nl> Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/lm7810
1 files changed, 0 insertions, 10 deletions
diff --git a/Documentation/hwmon/lm78 b/Documentation/hwmon/lm78
index fd5dc7a19f0..dfc318a60fd 100644
--- a/Documentation/hwmon/lm78
+++ b/Documentation/hwmon/lm78
@@ -56,16 +56,6 @@ should work with. This is hardcoded by the mainboard and/or processor itself.
56It is a value in volts. When it is unconnected, you will often find the 56It is a value in volts. When it is unconnected, you will often find the
57value 3.50 V here. 57value 3.50 V here.
58 58
59In addition to the alarms described above, there are a couple of additional
60ones. There is a BTI alarm, which gets triggered when an external chip has
61crossed its limits. Usually, this is connected to all LM75 chips; if at
62least one crosses its limits, this bit gets set. The CHAS alarm triggers
63if your computer case is open. The FIFO alarms should never trigger; it
64indicates an internal error. The SMI_IN alarm indicates some other chip
65has triggered an SMI interrupt. As we do not use SMI interrupts at all,
66this condition usually indicates there is a problem with some other
67device.
68
69If an alarm triggers, it will remain triggered until the hardware register 59If an alarm triggers, it will remain triggered until the hardware register
70is read at least once. This means that the cause for the alarm may 60is read at least once. This means that the cause for the alarm may
71already have disappeared! Note that in the current implementation, all 61already have disappeared! Note that in the current implementation, all