diff options
| author | Tomaz Mertelj <tomaz.mertelj@guest.arnes.si> | 2010-01-08 17:43:04 -0500 |
|---|---|---|
| committer | Linus Torvalds <torvalds@linux-foundation.org> | 2010-01-11 12:34:06 -0500 |
| commit | b5430a04e995081a308b4419bd0940f2badc6e6b (patch) | |
| tree | 47f214dbf6126043fd9f7faa8103a72446734309 /Documentation | |
| parent | 24f3c59e1781435835083eab587399c8bdc235b4 (diff) | |
hwmon: driver for Texas Instruments amc6821 chip
Signed-off-by: <tomaz.mertelj@guest.arnes.si>
Cc: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'Documentation')
| -rw-r--r-- | Documentation/hwmon/amc6821 | 102 |
1 files changed, 102 insertions, 0 deletions
diff --git a/Documentation/hwmon/amc6821 b/Documentation/hwmon/amc6821 new file mode 100644 index 00000000000..ced8359c50f --- /dev/null +++ b/Documentation/hwmon/amc6821 | |||
| @@ -0,0 +1,102 @@ | |||
| 1 | Kernel driver amc6821 | ||
| 2 | ===================== | ||
| 3 | |||
| 4 | Supported chips: | ||
| 5 | Texas Instruments AMC6821 | ||
| 6 | Prefix: 'amc6821' | ||
| 7 | Addresses scanned: 0x18, 0x19, 0x1a, 0x2c, 0x2d, 0x2e, 0x4c, 0x4d, 0x4e | ||
| 8 | Datasheet: http://focus.ti.com/docs/prod/folders/print/amc6821.html | ||
| 9 | |||
| 10 | Authors: | ||
| 11 | Tomaz Mertelj <tomaz.mertelj@guest.arnes.si> | ||
| 12 | |||
| 13 | |||
| 14 | Description | ||
| 15 | ----------- | ||
| 16 | |||
| 17 | This driver implements support for the Texas Instruments amc6821 chip. | ||
| 18 | The chip has one on-chip and one remote temperature sensor and one pwm fan | ||
| 19 | regulator. | ||
| 20 | The pwm can be controlled either from software or automatically. | ||
| 21 | |||
| 22 | The driver provides the following sensor accesses in sysfs: | ||
| 23 | |||
| 24 | temp1_input ro on-chip temperature | ||
| 25 | temp1_min rw " | ||
| 26 | temp1_max rw " | ||
| 27 | temp1_crit rw " | ||
| 28 | temp1_min_alarm ro " | ||
| 29 | temp1_max_alarm ro " | ||
| 30 | temp1_crit_alarm ro " | ||
| 31 | |||
| 32 | temp2_input ro remote temperature | ||
| 33 | temp2_min rw " | ||
| 34 | temp2_max rw " | ||
| 35 | temp2_crit rw " | ||
| 36 | temp2_min_alarm ro " | ||
| 37 | temp2_max_alarm ro " | ||
| 38 | temp2_crit_alarm ro " | ||
| 39 | temp2_fault ro " | ||
| 40 | |||
| 41 | fan1_input ro tachometer speed | ||
| 42 | fan1_min rw " | ||
| 43 | fan1_max rw " | ||
| 44 | fan1_fault ro " | ||
| 45 | fan1_div rw Fan divisor can be either 2 or 4. | ||
| 46 | |||
| 47 | pwm1 rw pwm1 | ||
| 48 | pwm1_enable rw regulator mode, 1=open loop, 2=fan controlled | ||
| 49 | by remote temperature, 3=fan controlled by | ||
| 50 | combination of the on-chip temperature and | ||
| 51 | remote-sensor temperature, | ||
| 52 | pwm1_auto_channels_temp ro 1 if pwm_enable==2, 3 if pwm_enable==3 | ||
| 53 | pwm1_auto_point1_pwm ro Hardwired to 0, shared for both | ||
| 54 | temperature channels. | ||
| 55 | pwm1_auto_point2_pwm rw This value is shared for both temperature | ||
| 56 | channels. | ||
| 57 | pwm1_auto_point3_pwm rw Hardwired to 255, shared for both | ||
| 58 | temperature channels. | ||
| 59 | |||
| 60 | temp1_auto_point1_temp ro Hardwired to temp2_auto_point1_temp | ||
| 61 | which is rw. Below this temperature fan stops. | ||
| 62 | temp1_auto_point2_temp rw The low-temperature limit of the proportional | ||
| 63 | range. Below this temperature | ||
| 64 | pwm1 = pwm1_auto_point2_pwm. It can go from | ||
| 65 | 0 degree C to 124 degree C in steps of | ||
| 66 | 4 degree C. Read it out after writing to get | ||
| 67 | the actual value. | ||
| 68 | temp1_auto_point3_temp rw Above this temperature fan runs at maximum | ||
| 69 | speed. It can go from temp1_auto_point2_temp. | ||
| 70 | It can only have certain discrete values | ||
| 71 | which depend on temp1_auto_point2_temp and | ||
| 72 | pwm1_auto_point2_pwm. Read it out after | ||
| 73 | writing to get the actual value. | ||
| 74 | |||
| 75 | temp2_auto_point1_temp rw Must be between 0 degree C and 63 degree C and | ||
| 76 | it defines the passive cooling temperature. | ||
| 77 | Below this temperature the fan stops in | ||
| 78 | the closed loop mode. | ||
| 79 | temp2_auto_point2_temp rw The low-temperature limit of the proportional | ||
| 80 | range. Below this temperature | ||
| 81 | pwm1 = pwm1_auto_point2_pwm. It can go from | ||
| 82 | 0 degree C to 124 degree C in steps | ||
| 83 | of 4 degree C. | ||
| 84 | |||
| 85 | temp2_auto_point3_temp rw Above this temperature fan runs at maximum | ||
| 86 | speed. It can only have certain discrete | ||
| 87 | values which depend on temp2_auto_point2_temp | ||
| 88 | and pwm1_auto_point2_pwm. Read it out after | ||
| 89 | writing to get actual value. | ||
| 90 | |||
| 91 | |||
| 92 | Module parameters | ||
| 93 | ----------------- | ||
| 94 | |||
| 95 | If your board has a BIOS that initializes the amc6821 correctly, you should | ||
| 96 | load the module with: init=0. | ||
| 97 | |||
| 98 | If your board BIOS doesn't initialize the chip, or you want | ||
| 99 | different settings, you can set the following parameters: | ||
| 100 | init=1, | ||
| 101 | pwminv: 0 default pwm output, 1 inverts pwm output. | ||
| 102 | |||