diff options
author | Roland Dreier <roland@purestorage.com> | 2017-03-01 21:22:01 -0500 |
---|---|---|
committer | Sagi Grimberg <sagi@grimberg.me> | 2017-04-02 03:24:07 -0400 |
commit | bf17aa36c0f199f5b254262e77eaefda7da0f50b (patch) | |
tree | 3d30544ababa479a1f47f31c9d85f7c830e633f6 | |
parent | ac77a0c463c1d7d659861f7b6d1261970dd3282a (diff) |
nvme: Correct NVMF enum values to match NVMe-oF rev 1.0
The enum values for QPTYPE, PRTYPE and CMS are off by 1 from the
values defined in figure 42 of the NVM Express over Fabrics 1.0:
http://www.nvmexpress.org/wp-content/uploads/NVMe_over_Fabrics_1_0_Gold_20160605-1.pdf
Fix our enums to match the final spec.
Signed-off-by: Roland Dreier <roland@purestorage.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
-rw-r--r-- | include/linux/nvme.h | 16 |
1 files changed, 8 insertions, 8 deletions
diff --git a/include/linux/nvme.h b/include/linux/nvme.h index c43d435d4225..9061780b141f 100644 --- a/include/linux/nvme.h +++ b/include/linux/nvme.h | |||
@@ -64,26 +64,26 @@ enum { | |||
64 | * RDMA_QPTYPE field | 64 | * RDMA_QPTYPE field |
65 | */ | 65 | */ |
66 | enum { | 66 | enum { |
67 | NVMF_RDMA_QPTYPE_CONNECTED = 0, /* Reliable Connected */ | 67 | NVMF_RDMA_QPTYPE_CONNECTED = 1, /* Reliable Connected */ |
68 | NVMF_RDMA_QPTYPE_DATAGRAM = 1, /* Reliable Datagram */ | 68 | NVMF_RDMA_QPTYPE_DATAGRAM = 2, /* Reliable Datagram */ |
69 | }; | 69 | }; |
70 | 70 | ||
71 | /* RDMA QP Service Type codes for Discovery Log Page entry TSAS | 71 | /* RDMA QP Service Type codes for Discovery Log Page entry TSAS |
72 | * RDMA_QPTYPE field | 72 | * RDMA_QPTYPE field |
73 | */ | 73 | */ |
74 | enum { | 74 | enum { |
75 | NVMF_RDMA_PRTYPE_NOT_SPECIFIED = 0, /* No Provider Specified */ | 75 | NVMF_RDMA_PRTYPE_NOT_SPECIFIED = 1, /* No Provider Specified */ |
76 | NVMF_RDMA_PRTYPE_IB = 1, /* InfiniBand */ | 76 | NVMF_RDMA_PRTYPE_IB = 2, /* InfiniBand */ |
77 | NVMF_RDMA_PRTYPE_ROCE = 2, /* InfiniBand RoCE */ | 77 | NVMF_RDMA_PRTYPE_ROCE = 3, /* InfiniBand RoCE */ |
78 | NVMF_RDMA_PRTYPE_ROCEV2 = 3, /* InfiniBand RoCEV2 */ | 78 | NVMF_RDMA_PRTYPE_ROCEV2 = 4, /* InfiniBand RoCEV2 */ |
79 | NVMF_RDMA_PRTYPE_IWARP = 4, /* IWARP */ | 79 | NVMF_RDMA_PRTYPE_IWARP = 5, /* IWARP */ |
80 | }; | 80 | }; |
81 | 81 | ||
82 | /* RDMA Connection Management Service Type codes for Discovery Log Page | 82 | /* RDMA Connection Management Service Type codes for Discovery Log Page |
83 | * entry TSAS RDMA_CMS field | 83 | * entry TSAS RDMA_CMS field |
84 | */ | 84 | */ |
85 | enum { | 85 | enum { |
86 | NVMF_RDMA_CMS_RDMA_CM = 0, /* Sockets based enpoint addressing */ | 86 | NVMF_RDMA_CMS_RDMA_CM = 1, /* Sockets based endpoint addressing */ |
87 | }; | 87 | }; |
88 | 88 | ||
89 | #define NVMF_AQ_DEPTH 32 | 89 | #define NVMF_AQ_DEPTH 32 |