aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/clk/ti/clk-dra7-atl.c
Commit message (Collapse)AuthorAge
* clk: ti: dra7-atl-clock: Fix of_node reference countingPeter Ujfalusi2016-04-19
| | | | | | | | | | | of_find_node_by_name() will call of_node_put() on the node so we need to get it first to avoid warnings. The cfg_node needs to be put after we have finished processing the properties. Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com> Tested-by: Nishanth Menon <nm@ti.com> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
* clk: ti: Include clk.hStephen Boyd2015-07-20
| | | | | | | | This clock provider uses the consumer API, so include clk.h explicitly. Acked-by: Tero Kristo <t-kristo@ti.com> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
* clk: ti: Silence sparse warningsStephen Boyd2015-05-14
| | | | | | | | | | | | | | | | | | | drivers/clk/ti/clk.c:125:31: warning: incorrect type in return expression (different address spaces) drivers/clk/ti/clk.c:125:31: expected void [noderef] <asn:2>* drivers/clk/ti/clk.c:125:31: got void * drivers/clk/ti/clk.c:132:31: warning: incorrect type in return expression (different address spaces) drivers/clk/ti/clk.c:132:31: expected void [noderef] <asn:2>* drivers/clk/ti/clk.c:132:31: got void * drivers/clk/ti/dpll.c:180:14: warning: symbol '_get_reg' was not declared. Should it be static? drivers/clk/ti/fapll.c:624:32: warning: Using plain integer as NULL pointer drivers/clk/ti/fapll.c:625:31: warning: Using plain integer as NULL pointer drivers/clk/ti/fapll.c:630:40: warning: Using plain integer as NULL pointer drivers/clk/ti/clk-dra7-atl.c:158:22: warning: symbol 'atl_clk_ops' was not declared. Should it be static? drivers/clk/ti/clk-dra7-atl.c:170:39: warning: Using plain integer as NULL pointer Acked-by: Peter Ujfalusi <peter.ujfalusi@ti.com> Acked-by: Tero Kristo <t-kristo@ti.com> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
* clk: ti: dra7-atl-clock: Fix possible ERR_PTR dereferenceKrzysztof Kozlowski2015-05-14
| | | | | | | | | | | | of_clk_get_from_provider() returns ERR_PTR on failure. The dra7-atl-clock driver was not checking its return value and immediately used it in __clk_get_hw(). __clk_get_hw() dereferences supplied clock, if it is not NULL, so in that case it would dereference an ERR_PTR. Fixes: 9ac33b0ce81f ("CLK: TI: Driver for DRA7 ATL (Audio Tracking Logic)") Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
* clk: constify of_device_id arrayFabian Frederick2015-04-01
| | | | | | | | | | | of_device_id is always used as const. (See driver.of_match_table and open firmware functions) __initdata updated to __initconst for static const struct of_device_id ti_clkdm_match_table[] Signed-off-by: Fabian Frederick <fabf@skynet.be> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
* Merge branch 'for-v3.18/ti-clk-driver' of github.com:t-kristo/linux-pm into ↵Mike Turquette2014-09-30
|\ | | | | | | clk-next
| * clk: ti: dra7-atl-clock: Mark the device as pm_runtime_irq_safePeter Ujfalusi2014-09-29
| | | | | | | | | | | | | | It is safe to call the pm sync calls in interrupt context in this driver. Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com> Signed-off-by: Tero Kristo <t-kristo@ti.com>
| * clk: ti: dra7-atl-clock: fix a memory leakTero Kristo2014-09-29
| | | | | | | | | | | | | | | | | | | | | | of_clk_add_provider makes an internal copy of the parent_names property while its called, thus it is no longer needed after this call and can be freed. Signed-off-by: Tero Kristo <t-kristo@ti.com> Cc: Mike Turquette <mturquette@linaro.org> Cc: Peter Ujfalusi <peter.ujfalusi@ti.com> Acked-by: Peter Ujfalusi <peter.ujfalusi@ti.com>
* | clk: Remove .owner field for driverKiran Padwal2014-09-25
| | | | | | | | | | | | | | | | | | | | | | | | | | | | There is no need to init .owner field. Based on the patch from Peter Griffin <peter.griffin@linaro.org> "mmc: remove .owner field for drivers using module_platform_driver" This patch removes the superflous .owner field for drivers which use the module_platform_driver API, as this is overriden in platform_driver_register anyway." Signed-off-by: Kiran Padwal <kiran.padwal@smartplayin.com> Signed-off-by: Mike Turquette <mturquette@linaro.org>
* | clk: ti: dra7-atl: Provide error check for incoming parameters in set_rateNishanth Menon2014-08-21
|/ | | | | | | | | | | | Check for valid parameters in check rate. Else, we end up getting errors. This occurs as part of the inital clock tree update of child clock nodes where new_rate could be 0 for non functional clocks. Fixes: 9ac33b0ce81fa48 (" CLK: TI: Driver for DRA7 ATL (Audio Tracking Logic)") Signed-off-by: Nishanth Menon <nm@ti.com> Signed-off-by: Tero Kristo <t-kristo@ti.com>
* CLK: TI: Driver for DRA7 ATL (Audio Tracking Logic)Peter Ujfalusi2014-05-28
Audio Tracking Logic is designed to be used by HD Radio applications to synchronize the audio output clocks to the baseband clock. ATL can be also used to track errors between two reference clocks (BWS, AWS) and generate a modulated clock output which averages to some desired frequency. In essence ATL is generating a clock to be used by an audio codec and also to be used by the SoC as MCLK. To be able to integrate the ATL provided clocks to the clock tree we need two types of DT binding: - DT clock nodes to represent the ATL clocks towards the CCF - binding for the ATL IP itself which is going to handle the hw configuration The reason for this type of setup is that ATL itself is a separate device in the SoC, it has it's own address space and clock domain. Other IPs can use the ATL generated clock as their functional clock (McASPs for example) and external components like audio codecs can also use the very same clock as their MCLK. The ATL IP in DRA7 contains 4 ATL instences. Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com> Signed-off-by: Tero Kristo <t-kristo@ti.com>