of: thermal: Fix inconsitency between cooling-*-state and cooling-*-level
The device trees in the kernel as well as the binding description in Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt use the cooling-{min,max}-level property. Fix the inconsistency with the binding description in Documentation/devicetree/bindings/thermal/thermal.txt by changing cooling-*-state properties to cooling-*-level. Signed-off-by: Punit Agrawal <punit.agrawal@arm.com> Cc: Eduardo Valentin <edubezval@gmail.com> Cc: Rob Herring <robh+dt@kernel.org> Cc: Mark Rutland <mark.rutland@arm.com> Cc: Ian Campbell <ijc+devicetree@hellion.org.uk> Cc: Kumar Gala <galak@codeaurora.org> Signed-off-by: Rob Herring <robh@kernel.org>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/thermal/thermal.txt14
1 files changed, 7 insertions, 7 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
index 8a49362dea6e..8320186738ff 100644
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal.txt
@@ -55,16 +55,16 @@ of heat dissipation). For example a fan's cooling states correspond to
55the different fan speeds possible. Cooling states are referred to by 55the different fan speeds possible. Cooling states are referred to by
56single unsigned integers, where larger numbers mean greater heat 56single unsigned integers, where larger numbers mean greater heat
57dissipation. The precise set of cooling states associated with a device 57dissipation. The precise set of cooling states associated with a device
58(as referred to be the cooling-min-state and cooling-max-state 58(as referred to by the cooling-min-level and cooling-max-level
59properties) should be defined in a particular device's binding. 59properties) should be defined in a particular device's binding.
60For more examples of cooling devices, refer to the example sections below. 60For more examples of cooling devices, refer to the example sections below.
61 61
62Required properties: 62Required properties:
63- cooling-min-state: An integer indicating the smallest 63- cooling-min-level: An integer indicating the smallest
64 Type: unsigned cooling state accepted. Typically 0. 64 Type: unsigned cooling state accepted. Typically 0.
65 Size: one cell 65 Size: one cell
66 66
67- cooling-max-state: An integer indicating the largest 67- cooling-max-level: An integer indicating the largest
68 Type: unsigned cooling state accepted. 68 Type: unsigned cooling state accepted.
69 Size: one cell 69 Size: one cell
70 70
@@ -225,8 +225,8 @@ cpus {
225 396000 950000 225 396000 950000
226 198000 850000 226 198000 850000
227 >; 227 >;
228 cooling-min-state = <0>; 228 cooling-min-level = <0>;
229 cooling-max-state = <3>; 229 cooling-max-level = <3>;
230 #cooling-cells = <2>; /* min followed by max */ 230 #cooling-cells = <2>; /* min followed by max */
231 }; 231 };
232 ... 232 ...
@@ -240,8 +240,8 @@ cpus {
240 */ 240 */
241 fan0: fan@0x48 { 241 fan0: fan@0x48 {
242 ... 242 ...
243 cooling-min-state = <0>; 243 cooling-min-level = <0>;
244 cooling-max-state = <9>; 244 cooling-max-level = <9>;
245 #cooling-cells = <2>; /* min followed by max */ 245 #cooling-cells = <2>; /* min followed by max */
246 }; 246 };
247}; 247};