aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/networking/slicecom.txt
blob: 59cfd95121fbcb4c8ade890c9a9e739d1d6b2f77 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369

SliceCOM adapter user's documentation - for the 0.51 driver version

Written by Bartók István <bartoki@itc.hu>

English translation: Lakatos György <gyuri@itc.hu>
Mon Dec 11 15:28:42 CET 2000

Last modified: Wed Aug 29 17:25:37 CEST 2001

-----------------------------------------------------------------

Usage:

Compiling the kernel:

Code maturity level options
	[*] Prompt for development and/or incomplete code/drivers

Network device support
	Wan interfaces
		<M> MultiGate (COMX) synchronous
			<M> Support for MUNICH based boards: SliceCOM, PCICOM (NEW)
			<M> Support for HDLC and syncPPP...


Loading the modules:

modprobe comx

modprobe comx-proto-ppp		# module for  Cisco-HDLC and SyncPPP protocols

modprobe comx-hw-munich		# the module logs information by the kernel
				# about the detected boards


Configuring the board:

# This interface will use the Cisco-HDLC line protocol,
# the timeslices assigned are 1,2 (128 KiBit line speed)
# (the first data timeslice in the G.703 frame is no. 1)
#
mkdir /proc/comx/comx0.1/
echo slicecom	>/proc/comx/comx0.1/boardtype
echo hdlc	>/proc/comx/comx0.1/protocol
echo 1 2	>/proc/comx/comx0.1/timeslots


# This interface uses SyncPPP line protocol, the assigned 
# is no. 3 (64 KiBit line speed)
#
mkdir /proc/comx/comx0.2/
echo slicecom	>/proc/comx/comx0.2/boardtype
echo ppp	>/proc/comx/comx0.2/protocol
echo 3		>/proc/comx/comx0.2/timeslots

...

ifconfig comx0.1 up
ifconfig comx0.2 up

-----------------------------------------------------------------

The COMX interfaces use a 10 packet transmit queue by default, however WAN
networks sometimes use bigger values (20 to 100), to utilize the line better
by large traffic (though the line delay increases because of more packets
join the queue).

# ifconfig comx0 txqueuelen 50

This option is only supported by the ifconfig command of the later 
distributions, which came with 2.2 kernels, such as RedHat 6.1 or Debian 2.2.

You can download a newer netbase packet from 
http://www.debian.org/~rcw/2.2/netbase/ for Debian 2.1, which has a new
ifconfig. You can get further information about using 2.2 kernel with
Debian 2.1 from http://www.debian.org/releases/stable/running-kernel-2.2

-----------------------------------------------------------------

The SliceCom LEDs:

red	- on, if the interface is unconfigured, or it gets Remote Alarm-s
green	- on, if the board finds frame-sync in the received signal 	

A bit more detailed:

red:	green:	meaning:

-	-	no frame-sync, no signal received, or signal SNAFU.
-	on	"Everything is OK"
on	on	Recepion is ok, but the remote end sends Remote Alarm
on	-	The interface is unconfigured

-----------------------------------------------------------------

A more detailed description of the hardware setting options:

The general and the protocol layer options described in the 'comx.txt' file
apply to the SliceCom as well, I only summarize the SliceCom hardware specific
settings below.

The '/proc/comx' configuring interface:

An interface directory should be created for every timeslot group with
'mkdir', e,g: 'comx0', 'comx1' etc. The timeslots can be assigned here to the
specific interface. The Cisco-like naming convention (serial3:1 - first
timeslot group of the 3rd. board) can't be used here, because these mean IP
aliasing in Linux.

You can give any meaningful name to keep the configuration clear; 
e.g: 'comx0.1', 'comx0.2', 'comx1.1', comx1.2', if you have two boards
with two interfaces each.

Settings, which apply to the board:

Neither 'io' nor 'irq' settings required, the driver uses the resources
given by the PCI BIOS.

comx0/boardnum	- board number of the SliceCom in the PC (using the 'natural'
		PCI order) as listed in '/proc/pci' or the output of the
	 	'lspci' command, generally the slots nearer to the motherboard
		PCI driver chips have the lower numbers.
		
		Default: 0 (the counting starts with 0)

Though the options below are to be set on a single interface, they apply to the
whole board. The restriction, to use them on 'UP' interfaces, is because the 
command sequence below could lead to unpredicable results.

	# echo 0        >boardnum
	# echo internal >clock_source
	# echo 1        >boardnum

The sequence would set the clock source of board 0.

These settings will persist after all the interfaces are cleared, but are
cleared when the driver module is unloaded and loaded again.

comx0/clock_source - source of the transmit clock
	Usage:

	# echo line     >/proc/comx/comx0/clock_source
	# echo internal >/proc/comx/comx0/clock_source

	line	- The Tx clock is being decoded if the input data stream,
		if no clock seen on the input, then the board will use it's
		own clock generator.

	internal - The Tx clock is supplied by the builtin clock generator. 	

	Default: line

	Normally, the telecommunication company's end device (the HDSL
	modem) provides the Tx clock, that's why 'line' is the default.

comx0/framing	- Switching CRC4 off/on

	CRC4: 16 PCM frames (The 32 64Kibit channels are multiplexed into a
	PCM frame, nothing to do with HDLC frames) are divided into 2x8
	groups, each group has a 4 bit CRC.

	# echo crc4	>/proc/comx/comx0/framing
	# echo no-crc4	>/proc/comx/comx0/framing

	Default is 'crc4', the Hungarian MATAV lines behave like this. 
	The traffic generally passes if this setting on both ends don't match.

comx0/linecode	- Setting the line coding

	# echo hdb3	>/proc/comx/comx0/linecode
	# echo ami	>/proc/comx/comx0/linecode

	Default a 'hdb3', MATAV lines use this.
	
	(AMI coding is rarely used with E1 lines). Frame sync may occur, if
	this setting doesn't match the other end's, but CRC4 and data errors
	will come, which will result in CRC errors on HDLC/SyncPPP level. 

comx0/reg	- direct access to the board's MUNICH (reg) and FALC (lbireg)
comx0/lbireg	circuit's registers  

	# echo >reg 0x04 0x0	- write 0 to register 4
	# echo >reg 0x104	- write the contents of register 4 with
				printk() to syslog

WARNING! These are only for development purposes, messing with this will
	result much trouble!

comx0/loopback - Places a loop to the board's G.703 signals

	# echo none   >/proc/comx/comx0/loopback
	# echo local  >/proc/comx/comx0/loopback
	# echo remote >/proc/comx/comx0/loopback

	none   - normal operation, no loop
	local  - the board receives it's own output
	remote - the board sends the received data to the remote side

	Default: none

-----------------------------------------------------------------

Interface (channel group in Cisco terms) settings: 

comx0/timeslots	- which timeslots belong to the given interface

	Setting:

	# echo '1 5 2 6 7 8' >/proc/comx/comx0/timeslots

	# cat /proc/comx/comx0/timeslots
	1 2 5 6 7 8 
	#

	Finding a timeslot: 

	# grep ' 4' /proc/comx/comx*/timeslots
	/proc/comx/comx0/timeslots:1 3 4 5 6
	#

	The timeslots can be in any order, '1 2 3' is the same as '1 3 2'.

	The interface has to be DOWN during the setting ('ifconfig comx0
	down'), but the other interfaces could operate normally.

	The driver checks if the assigned timeslots are vacant, if not, then
	the setting won't be applied.

	The timeslot values are treated as decimal numbers, not to misunderstand
	values of 08, 09 form.

-----------------------------------------------------------------

Checking the interface and board status:

- Lines beginning with ' ' (space) belong to the original output, the lines
which begin with '//' are the comments.

 papaya:~$ cat /proc/comx/comx1/status
 Interface administrative status is UP, modem status is UP, protocol is UP
 Modem status changes: 0, Transmitter status is IDLE, tbusy: 0
 Interface load (input): 978376 / 947808 / 951024 bits/s (5s/5m/15m)
               (output): 978376 / 947848 / 951024 bits/s (5s/5m/15m)
 Debug flags: none
 RX errors: len: 22, overrun: 1, crc: 0, aborts: 0
            buffer overrun: 0, pbuffer overrun: 0
 TX errors: underrun: 0
 Line keepalive (value: 10) status UP [0]

// The hardware specific part starts here:
 Controller status:
         No alarms

// Alarm: 
//
// No alarms - Everything OK
//
// LOS  - Loss Of Signal - No signal sensed on the input
// AIS  - Alarm Indication Signal - The remot side sends '11111111'-s, 
//	it tells, that there's an error condition, or it's not
//	initialised.
// AUXP - Auxiliary Pattern Indication - 01010101.. received.
// LFA  - Loss of Frame Alignment - no frame sync received.
// RRA  - Receive Remote Alarm - the remote end's OK, but singnals error cond.
// LMFA - Loss of CRC4 Multiframe Alignment - no CRC4 multiframe sync.
// NMF  - No Multiframe alignment Found after 400 msec - no such alarm using
//	no-crc4 or crc4 framing, see below.
//
// Other possible error messages:
//
// Transmit Line Short - the board felt, that it's output is short-circuited,
// 	so it switched the transmission off. (The board can't definitely tell,
//	that it's output is short-circuited.)

// Chained list of the received packets, for debug purposes:

 Rx ring:
         rafutott: 0
         lastcheck: 50845731, jiffies: 51314281
         base: 017b1858
         rx_desc_ptr: 0
         rx_desc_ptr: 017b1858
         hw_curr_ptr: 017b1858
         06040000 017b1868 017b1898 c016ff00
         06040000 017b1878 017b1e9c c016ff00
         46040000 017b1888 017b24a0 c016ff00
         06040000 017b1858 017b2aa4 c016ff00

// All the interfaces using the board: comx1, using the 1,2,...16 timeslots,
// comx2, using timeslot 17, etc.

 Interfaces using this board: (channel-group, interface, timeslots)
          0 comx1: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
          1 comx2: 17
          2 comx3: 18
          3 comx4: 19
          4 comx5: 20
          5 comx6: 21
          6 comx7: 22
          7 comx8: 23
          8 comx9: 24
          9 comx10: 25
         10 comx11: 26
         11 comx12: 27
         12 comx13: 28
         13 comx14: 29
         14 comx15: 30
         15 comx16: 31

// The number of events handled by the driver during an interrupt cycle:

 Interrupt work histogram:
 hist[ 0]:        0 hist[ 1]:        2 hist[ 2]:    18574 hist[ 3]:       79
 hist[ 4]:       14 hist[ 5]:        1 hist[ 6]:        0 hist[ 7]:        1
 hist[ 8]:        0 hist[ 9]:        7

// The number of packets to send in the Tx ring, when a new one arrived:

 Tx ring histogram:
 hist[ 0]:     2329 hist[ 1]:        0 hist[ 2]:        0 hist[ 3]:        0

// The error counters of the E1 interface, according to the RFC2495,
// (similar to the Cisco "show controllers e1" command's output:
// http://www.cisco.com/univercd/cc/td/doc/product/software/ios11/rbook/rinterfc.htm#xtocid25669126)

Data in current interval (91 seconds elapsed):
   9516 Line Code Violations, 65 Path Code Violations, 2 E-Bit Errors
   0 Slip Secs, 2 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins
   0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 11 Unavail Secs
Data in Interval 1 (15 minutes):
   0 Line Code Violations, 0 Path Code Violations, 0 E-Bit Errors
   0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
   0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in last 4 intervals (1 hour):
   0 Line Code Violations, 0 Path Code Violations, 0 E-Bit Errors
   0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
   0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in last 96 intervals (24 hours):
   0 Line Code Violations, 0 Path Code Violations, 0 E-Bit Errors
   0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
   0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs

-----------------------------------------------------------------

Some unique options, (may get into the driver later):
Treat them very carefully, these can cause much trouble!

	modified CRC-4, for improved interworking of CRC-4 and non-CRC-4
	devices: (see page 107 and g706 Annex B)
		lbireg[ 0x1b ] |= 0x08
		lbireg[ 0x1c ] |= 0xc0

	- The NMF - 'No Multiframe alignment Found after 400 msec' alarm 
	comes into account.

	FALC - the line driver chip.
	local loop - I hear my transmission back.
	remote loop - I echo the remote transmission back.

	Something useful for finding errors:
	
		- local loop for timeslot 1 in the FALC chip:

	# echo >lbireg 0x1d 0x21

		- Swithing the loop off:

	# echo >lbireg 0x1d 0x00