From ec06aedd44541129840ed52e6165afa3796a27bf Mon Sep 17 00:00:00 2001 From: Jeff Layton Date: Fri, 6 Nov 2009 14:18:29 -0500 Subject: cifs: clean up handling when server doesn't consistently support inode numbers It's possible that a server will return a valid FileID when we query the FILE_INTERNAL_INFO for the root inode, but then zeroed out inode numbers when we do a FindFile with an infolevel of SMB_FIND_FILE_ID_FULL_DIR_INFO. In this situation turn off querying for server inode numbers, generate a warning for the user and just generate an inode number using iunique. Once we generate any inode number with iunique we can no longer use any server inode numbers or we risk collisions, so ensure that we don't do that in cifs_get_inode_info either. Cc: Stable Reported-by: Timothy Normand Miller Signed-off-by: Jeff Layton Signed-off-by: Steve French --- fs/cifs/readdir.c | 7 ++++--- 1 file changed, 4 insertions(+), 3 deletions(-) (limited to 'fs/cifs/readdir.c') diff --git a/fs/cifs/readdir.c b/fs/cifs/readdir.c index 1f098ca71636..f84062f9a985 100644 --- a/fs/cifs/readdir.c +++ b/fs/cifs/readdir.c @@ -727,11 +727,12 @@ static int cifs_filldir(char *pfindEntry, struct file *file, filldir_t filldir, cifs_dir_info_to_fattr(&fattr, (FILE_DIRECTORY_INFO *) pfindEntry, cifs_sb); - /* FIXME: make _to_fattr functions fill this out */ - if (pCifsF->srch_inf.info_level == SMB_FIND_FILE_ID_FULL_DIR_INFO) + if (inum && (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM)) { fattr.cf_uniqueid = inum; - else + } else { fattr.cf_uniqueid = iunique(sb, ROOT_I); + cifs_autodisable_serverino(cifs_sb); + } ino = cifs_uniqueid_to_ino_t(fattr.cf_uniqueid); tmp_dentry = cifs_readdir_lookup(file->f_dentry, &qstring, &fattr); -- cgit v1.2.2