aboutsummaryrefslogtreecommitdiffstats
path: root/include/asm-sparc64/ldc.h
Commit message (Collapse)AuthorAge
* [SPARC64]: Fix build regressions added by dr-cpu changes.David S. Miller2007-07-16
| | | | | | | | | | | | | | | Do not select HOTPLUG_CPU from SUN_LDOMS, that causes HOTPLUG_CPU to be selected even on non-SMP which is illegal. Only build hvtramp.o when SMP, just like trampoline.o Protect dr-cpu code in ds.c with HOTPLUG_CPU. Likewise move ldom_startcpu_cpuid() to smp.c and protect it and the call site with SUN_LDOMS && HOTPLUG_CPU. Signed-off-by: David S. Miller <davem@davemloft.net>
* [SPARC64]: Initial LDOM cpu hotplug support.David S. Miller2007-07-16
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Only adding cpus is supports at the moment, removal will come next. When new cpus are configured, the machine description is updated. When we get the configure request we pass in a cpu mask of to-be-added cpus to the mdesc CPU node parser so it only fetches information for those cpus. That code also proceeds to update the SMT/multi-core scheduling bitmaps. cpu_up() does all the work and we return the status back over the DS channel. CPUs via dr-cpu need to be booted straight out of the hypervisor, and this requires: 1) A new trampoline mechanism. CPUs are booted straight out of the hypervisor with MMU disabled and running in physical addresses with no mappings installed in the TLB. The new hvtramp.S code sets up the critical cpu state, installs the locked TLB mappings for the kernel, and turns the MMU on. It then proceeds to follow the logic of the existing trampoline.S SMP cpu bringup code. 2) All calls into OBP have to be disallowed when domaining is enabled. Since cpus boot straight into the kernel from the hypervisor, OBP has no state about that cpu and therefore cannot handle being invoked on that cpu. Luckily it's only a handful of interfaces which can be called after the OBP device tree is obtained. For example, rebooting, halting, powering-off, and setting options node variables. CPU removal support will require some infrastructure changes here. Namely we'll have to process the requests via a true kernel thread instead of in a workqueue. workqueues run on a per-cpu thread, but when unconfiguring we might need to force the thread to execute on another cpu if the current cpu is the one being removed. Removal of a cpu also causes the kernel to destroy that cpu's workqueue running thread. Another issue on removal is that we may have interrupts still pointing to the cpu-to-be-removed. So new code will be needed to walk the active INO list and retarget those cpus as-needed. Signed-off-by: David S. Miller <davem@davemloft.net>
* [SPARC64]: Fix setting of variables in LDOM guest.David S. Miller2007-07-16
| | | | | | | | | There is a special domain services capability for setting variables in the OBP options node. Guests don't have permanent store for the OBP variables like a normal system, so they are instead maintained in the LDOM control node or in the SC. Signed-off-by: David S. Miller <davem@davemloft.net>
* [SPARC64]: Use more mearningful names for IRQ registry.David S. Miller2007-07-16
| | | | | | | | | All of the interrupts say "LDX RX" and "LDX TX" currently which is next to useless. Put a device specific prefix before "RX" and "TX" instead which makes it much more useful. Signed-off-by: David S. Miller <davem@davemloft.net>
* [SPARC64]: Assorted LDC bug cures.David S. Miller2007-07-16
| | | | | | | | | | | | | | | | | | | | | | | | | | | 1) LDC_MODE_RELIABLE is deprecated an unused by anything, plus it and LDC_MODE_STREAM were mis-numbered. 2) read_stream() should try to read as much as possible into the per-LDC stream buffer area, so do not trim the read_nonraw() length by the caller's size parameter. 3) Send data ACKs when necessary in read_nonraw(). 4) In read_nonraw() when we get a pure ACK, advance the RX head unconditionally past it. 5) Provide the ACKID field in the ldcdgb() packet dump in read_nonraw(). This helps debugging stream mode LDC channel problems. 6) Decrease verbosity of rx_data_wait() so that it is more useful. A debugging message each loop iteration is too much. 7) In process_data_ack() stop the loop checking when we hit lp->tx_tail not lp->tx_head. 8) Set the seqid field properly in send_data_nack(). Signed-off-by: David S. Miller <davem@davemloft.net>
* [SPARC64]: Add LDOM virtual channel driver and VIO device layer.David S. Miller2007-07-16
Virtual devices on Sun Logical Domains are built on top of a virtual channel framework. This, with help of hypervisor interfaces, provides a link layer protocol with basic handshaking over which virtual device clients and servers communicate. Built on top of this is a VIO device protocol which has it's own handshaking and message types. At this layer attributes are exchanged (disk size, network device addresses, etc.) descriptor rings are registered, and data transfers are triggers and replied to. Signed-off-by: David S. Miller <davem@davemloft.net>