diff options
Diffstat (limited to 'drivers/mtd/maps/Kconfig')
-rw-r--r-- | drivers/mtd/maps/Kconfig | 73 |
1 files changed, 5 insertions, 68 deletions
diff --git a/drivers/mtd/maps/Kconfig b/drivers/mtd/maps/Kconfig index d29dc121c1f7..f036de8080b9 100644 --- a/drivers/mtd/maps/Kconfig +++ b/drivers/mtd/maps/Kconfig | |||
@@ -1,5 +1,5 @@ | |||
1 | # drivers/mtd/maps/Kconfig | 1 | # drivers/mtd/maps/Kconfig |
2 | # $Id: Kconfig,v 1.44 2005/02/18 11:03:45 bjd Exp $ | 2 | # $Id: Kconfig,v 1.45 2005/02/27 21:50:21 ppopov Exp $ |
3 | 3 | ||
4 | menu "Mapping drivers for chip access" | 4 | menu "Mapping drivers for chip access" |
5 | depends on MTD!=n | 5 | depends on MTD!=n |
@@ -213,74 +213,11 @@ config MTD_NETtel | |||
213 | help | 213 | help |
214 | Support for flash chips on NETtel/SecureEdge/SnapGear boards. | 214 | Support for flash chips on NETtel/SecureEdge/SnapGear boards. |
215 | 215 | ||
216 | config MTD_PB1XXX | 216 | config MTD_ALCHEMY |
217 | tristate "Flash devices on Alchemy PB1xxx boards" | 217 | tristate ' AMD Alchemy Pb1xxx/Db1xxx/RDK MTD support' |
218 | depends on MIPS && ( MIPS_PB1000 || MIPS_PB1100 || MIPS_PB1500 ) | 218 | depends on MIPS && SOC_AU1X00 |
219 | help | 219 | help |
220 | Flash memory access on Alchemy Pb1000/Pb1100/Pb1500 boards | 220 | Flash memory access on AMD Alchemy Pb/Db/RDK Reference Boards |
221 | |||
222 | config MTD_PB1XXX_BOOT | ||
223 | bool "PB1x00 boot flash device" | ||
224 | depends on MTD_PB1XXX && ( MIPS_PB1100 || MIPS_PB1500 ) | ||
225 | help | ||
226 | Use the first of the two 32MiB flash banks on Pb1100/Pb1500 board. | ||
227 | You can say 'Y' to both this and 'MTD_PB1XXX_USER' below, to use | ||
228 | both banks. | ||
229 | |||
230 | config MTD_PB1XXX_USER | ||
231 | bool "PB1x00 user flash device" | ||
232 | depends on MTD_PB1XXX && ( MIPS_PB1100 || MIPS_PB1500 ) | ||
233 | default y if MTD_PB1XX_BOOT = n | ||
234 | help | ||
235 | Use the second of the two 32MiB flash banks on Pb1100/Pb1500 board. | ||
236 | You can say 'Y' to both this and 'MTD_PB1XXX_BOOT' above, to use | ||
237 | both banks. | ||
238 | |||
239 | config MTD_PB1550 | ||
240 | tristate "Flash devices on Alchemy PB1550 board" | ||
241 | depends on MIPS && MIPS_PB1550 | ||
242 | help | ||
243 | Flash memory access on Alchemy Pb1550 board | ||
244 | |||
245 | config MTD_PB1550_BOOT | ||
246 | bool "PB1550 boot flash device" | ||
247 | depends on MTD_PB1550 | ||
248 | help | ||
249 | Use the first of the two 64MiB flash banks on Pb1550 board. | ||
250 | You can say 'Y' to both this and 'MTD_PB1550_USER' below, to use | ||
251 | both banks. | ||
252 | |||
253 | config MTD_PB1550_USER | ||
254 | bool "PB1550 user flash device" | ||
255 | depends on MTD_PB1550 | ||
256 | default y if MTD_PB1550_BOOT = n | ||
257 | help | ||
258 | Use the second of the two 64MiB flash banks on Pb1550 board. | ||
259 | You can say 'Y' to both this and 'MTD_PB1550_BOOT' above, to use | ||
260 | both banks. | ||
261 | |||
262 | config MTD_DB1550 | ||
263 | tristate "Flash devices on Alchemy DB1550 board" | ||
264 | depends on MIPS && MIPS_DB1550 | ||
265 | help | ||
266 | Flash memory access on Alchemy Db1550 board | ||
267 | |||
268 | config MTD_DB1550_BOOT | ||
269 | bool "DB1550 boot flash device" | ||
270 | depends on MTD_DB1550 | ||
271 | help | ||
272 | Use the first of the two 64MiB flash banks on Db1550 board. | ||
273 | You can say 'Y' to both this and 'MTD_DB1550_USER' below, to use | ||
274 | both banks. | ||
275 | |||
276 | config MTD_DB1550_USER | ||
277 | bool "DB1550 user flash device" | ||
278 | depends on MTD_DB1550 | ||
279 | default y if MTD_DB1550_BOOT = n | ||
280 | help | ||
281 | Use the second of the two 64MiB flash banks on Db1550 board. | ||
282 | You can say 'Y' to both this and 'MTD_DB1550_BOOT' above, to use | ||
283 | both banks. | ||
284 | 221 | ||
285 | config MTD_DILNETPC | 222 | config MTD_DILNETPC |
286 | tristate "CFI Flash device mapped on DIL/Net PC" | 223 | tristate "CFI Flash device mapped on DIL/Net PC" |