diff options
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-system-cpu | 15 | ||||
-rw-r--r-- | Documentation/cpu-hotplug.txt | 6 | ||||
-rw-r--r-- | Documentation/filesystems/ocfs2.txt | 6 | ||||
-rw-r--r-- | Documentation/i2c/busses/i2c-piix4 | 2 | ||||
-rw-r--r-- | Documentation/powerpc/dts-bindings/fsl/board.txt | 4 | ||||
-rw-r--r-- | Documentation/thermal/sysfs-api.txt | 389 | ||||
-rw-r--r-- | Documentation/vm/page-types.c | 2 |
7 files changed, 231 insertions, 193 deletions
diff --git a/Documentation/ABI/testing/sysfs-devices-system-cpu b/Documentation/ABI/testing/sysfs-devices-system-cpu index a703b9e9aeb9..d868a11c94a5 100644 --- a/Documentation/ABI/testing/sysfs-devices-system-cpu +++ b/Documentation/ABI/testing/sysfs-devices-system-cpu | |||
@@ -62,6 +62,21 @@ Description: CPU topology files that describe kernel limits related to | |||
62 | See Documentation/cputopology.txt for more information. | 62 | See Documentation/cputopology.txt for more information. |
63 | 63 | ||
64 | 64 | ||
65 | What: /sys/devices/system/cpu/probe | ||
66 | /sys/devices/system/cpu/release | ||
67 | Date: November 2009 | ||
68 | Contact: Linux kernel mailing list <linux-kernel@vger.kernel.org> | ||
69 | Description: Dynamic addition and removal of CPU's. This is not hotplug | ||
70 | removal, this is meant complete removal/addition of the CPU | ||
71 | from the system. | ||
72 | |||
73 | probe: writes to this file will dynamically add a CPU to the | ||
74 | system. Information written to the file to add CPU's is | ||
75 | architecture specific. | ||
76 | |||
77 | release: writes to this file dynamically remove a CPU from | ||
78 | the system. Information writtento the file to remove CPU's | ||
79 | is architecture specific. | ||
65 | 80 | ||
66 | What: /sys/devices/system/cpu/cpu#/node | 81 | What: /sys/devices/system/cpu/cpu#/node |
67 | Date: October 2009 | 82 | Date: October 2009 |
diff --git a/Documentation/cpu-hotplug.txt b/Documentation/cpu-hotplug.txt index 9d620c153b04..4d4a644b505e 100644 --- a/Documentation/cpu-hotplug.txt +++ b/Documentation/cpu-hotplug.txt | |||
@@ -49,6 +49,12 @@ maxcpus=n Restrict boot time cpus to n. Say if you have 4 cpus, using | |||
49 | additional_cpus=n (*) Use this to limit hotpluggable cpus. This option sets | 49 | additional_cpus=n (*) Use this to limit hotpluggable cpus. This option sets |
50 | cpu_possible_map = cpu_present_map + additional_cpus | 50 | cpu_possible_map = cpu_present_map + additional_cpus |
51 | 51 | ||
52 | cede_offline={"off","on"} Use this option to disable/enable putting offlined | ||
53 | processors to an extended H_CEDE state on | ||
54 | supported pseries platforms. | ||
55 | If nothing is specified, | ||
56 | cede_offline is set to "on". | ||
57 | |||
52 | (*) Option valid only for following architectures | 58 | (*) Option valid only for following architectures |
53 | - ia64 | 59 | - ia64 |
54 | 60 | ||
diff --git a/Documentation/filesystems/ocfs2.txt b/Documentation/filesystems/ocfs2.txt index c2a0871280a0..c58b9f5ba002 100644 --- a/Documentation/filesystems/ocfs2.txt +++ b/Documentation/filesystems/ocfs2.txt | |||
@@ -20,15 +20,16 @@ Lots of code taken from ext3 and other projects. | |||
20 | Authors in alphabetical order: | 20 | Authors in alphabetical order: |
21 | Joel Becker <joel.becker@oracle.com> | 21 | Joel Becker <joel.becker@oracle.com> |
22 | Zach Brown <zach.brown@oracle.com> | 22 | Zach Brown <zach.brown@oracle.com> |
23 | Mark Fasheh <mark.fasheh@oracle.com> | 23 | Mark Fasheh <mfasheh@suse.com> |
24 | Kurt Hackel <kurt.hackel@oracle.com> | 24 | Kurt Hackel <kurt.hackel@oracle.com> |
25 | Tao Ma <tao.ma@oracle.com> | ||
25 | Sunil Mushran <sunil.mushran@oracle.com> | 26 | Sunil Mushran <sunil.mushran@oracle.com> |
26 | Manish Singh <manish.singh@oracle.com> | 27 | Manish Singh <manish.singh@oracle.com> |
28 | Tiger Yang <tiger.yang@oracle.com> | ||
27 | 29 | ||
28 | Caveats | 30 | Caveats |
29 | ======= | 31 | ======= |
30 | Features which OCFS2 does not support yet: | 32 | Features which OCFS2 does not support yet: |
31 | - quotas | ||
32 | - Directory change notification (F_NOTIFY) | 33 | - Directory change notification (F_NOTIFY) |
33 | - Distributed Caching (F_SETLEASE/F_GETLEASE/break_lease) | 34 | - Distributed Caching (F_SETLEASE/F_GETLEASE/break_lease) |
34 | 35 | ||
@@ -70,7 +71,6 @@ commit=nrsec (*) Ocfs2 can be told to sync all its data and metadata | |||
70 | performance. | 71 | performance. |
71 | localalloc=8(*) Allows custom localalloc size in MB. If the value is too | 72 | localalloc=8(*) Allows custom localalloc size in MB. If the value is too |
72 | large, the fs will silently revert it to the default. | 73 | large, the fs will silently revert it to the default. |
73 | Localalloc is not enabled for local mounts. | ||
74 | localflocks This disables cluster aware flock. | 74 | localflocks This disables cluster aware flock. |
75 | inode64 Indicates that Ocfs2 is allowed to create inodes at | 75 | inode64 Indicates that Ocfs2 is allowed to create inodes at |
76 | any location in the filesystem, including those which | 76 | any location in the filesystem, including those which |
diff --git a/Documentation/i2c/busses/i2c-piix4 b/Documentation/i2c/busses/i2c-piix4 index c5b37c570554..ac540c71c7eb 100644 --- a/Documentation/i2c/busses/i2c-piix4 +++ b/Documentation/i2c/busses/i2c-piix4 | |||
@@ -8,7 +8,7 @@ Supported adapters: | |||
8 | Datasheet: Only available via NDA from ServerWorks | 8 | Datasheet: Only available via NDA from ServerWorks |
9 | * ATI IXP200, IXP300, IXP400, SB600, SB700 and SB800 southbridges | 9 | * ATI IXP200, IXP300, IXP400, SB600, SB700 and SB800 southbridges |
10 | Datasheet: Not publicly available | 10 | Datasheet: Not publicly available |
11 | * AMD SB900 | 11 | * AMD Hudson-2 |
12 | Datasheet: Not publicly available | 12 | Datasheet: Not publicly available |
13 | * Standard Microsystems (SMSC) SLC90E66 (Victory66) southbridge | 13 | * Standard Microsystems (SMSC) SLC90E66 (Victory66) southbridge |
14 | Datasheet: Publicly available at the SMSC website http://www.smsc.com | 14 | Datasheet: Publicly available at the SMSC website http://www.smsc.com |
diff --git a/Documentation/powerpc/dts-bindings/fsl/board.txt b/Documentation/powerpc/dts-bindings/fsl/board.txt index e8b5bc24d0ac..39e941515a36 100644 --- a/Documentation/powerpc/dts-bindings/fsl/board.txt +++ b/Documentation/powerpc/dts-bindings/fsl/board.txt | |||
@@ -20,12 +20,16 @@ Required properities: | |||
20 | - compatible : should be "fsl,fpga-pixis". | 20 | - compatible : should be "fsl,fpga-pixis". |
21 | - reg : should contain the address and the length of the FPPGA register | 21 | - reg : should contain the address and the length of the FPPGA register |
22 | set. | 22 | set. |
23 | - interrupt-parent: should specify phandle for the interrupt controller. | ||
24 | - interrupts : should specify event (wakeup) IRQ. | ||
23 | 25 | ||
24 | Example (MPC8610HPCD): | 26 | Example (MPC8610HPCD): |
25 | 27 | ||
26 | board-control@e8000000 { | 28 | board-control@e8000000 { |
27 | compatible = "fsl,fpga-pixis"; | 29 | compatible = "fsl,fpga-pixis"; |
28 | reg = <0xe8000000 32>; | 30 | reg = <0xe8000000 32>; |
31 | interrupt-parent = <&mpic>; | ||
32 | interrupts = <8 8>; | ||
29 | }; | 33 | }; |
30 | 34 | ||
31 | * Freescale BCSR GPIO banks | 35 | * Freescale BCSR GPIO banks |
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index 70d68ce8640a..a87dc277a5ca 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt | |||
@@ -1,5 +1,5 @@ | |||
1 | Generic Thermal Sysfs driver How To | 1 | Generic Thermal Sysfs driver How To |
2 | ========================= | 2 | =================================== |
3 | 3 | ||
4 | Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com> | 4 | Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com> |
5 | 5 | ||
@@ -10,20 +10,20 @@ Copyright (c) 2008 Intel Corporation | |||
10 | 10 | ||
11 | 0. Introduction | 11 | 0. Introduction |
12 | 12 | ||
13 | The generic thermal sysfs provides a set of interfaces for thermal zone devices (sensors) | 13 | The generic thermal sysfs provides a set of interfaces for thermal zone |
14 | and thermal cooling devices (fan, processor...) to register with the thermal management | 14 | devices (sensors) and thermal cooling devices (fan, processor...) to register |
15 | solution and to be a part of it. | 15 | with the thermal management solution and to be a part of it. |
16 | 16 | ||
17 | This how-to focuses on enabling new thermal zone and cooling devices to participate | 17 | This how-to focuses on enabling new thermal zone and cooling devices to |
18 | in thermal management. | 18 | participate in thermal management. |
19 | This solution is platform independent and any type of thermal zone devices and | 19 | This solution is platform independent and any type of thermal zone devices |
20 | cooling devices should be able to make use of the infrastructure. | 20 | and cooling devices should be able to make use of the infrastructure. |
21 | 21 | ||
22 | The main task of the thermal sysfs driver is to expose thermal zone attributes as well | 22 | The main task of the thermal sysfs driver is to expose thermal zone attributes |
23 | as cooling device attributes to the user space. | 23 | as well as cooling device attributes to the user space. |
24 | An intelligent thermal management application can make decisions based on inputs | 24 | An intelligent thermal management application can make decisions based on |
25 | from thermal zone attributes (the current temperature and trip point temperature) | 25 | inputs from thermal zone attributes (the current temperature and trip point |
26 | and throttle appropriate devices. | 26 | temperature) and throttle appropriate devices. |
27 | 27 | ||
28 | [0-*] denotes any positive number starting from 0 | 28 | [0-*] denotes any positive number starting from 0 |
29 | [1-*] denotes any positive number starting from 1 | 29 | [1-*] denotes any positive number starting from 1 |
@@ -31,77 +31,77 @@ and throttle appropriate devices. | |||
31 | 1. thermal sysfs driver interface functions | 31 | 1. thermal sysfs driver interface functions |
32 | 32 | ||
33 | 1.1 thermal zone device interface | 33 | 1.1 thermal zone device interface |
34 | 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name, int trips, | 34 | 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name, |
35 | void *devdata, struct thermal_zone_device_ops *ops) | 35 | int trips, void *devdata, struct thermal_zone_device_ops *ops) |
36 | 36 | ||
37 | This interface function adds a new thermal zone device (sensor) to | 37 | This interface function adds a new thermal zone device (sensor) to |
38 | /sys/class/thermal folder as thermal_zone[0-*]. | 38 | /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the |
39 | It tries to bind all the thermal cooling devices registered at the same time. | 39 | thermal cooling devices registered at the same time. |
40 | 40 | ||
41 | name: the thermal zone name. | 41 | name: the thermal zone name. |
42 | trips: the total number of trip points this thermal zone supports. | 42 | trips: the total number of trip points this thermal zone supports. |
43 | devdata: device private data | 43 | devdata: device private data |
44 | ops: thermal zone device call-backs. | 44 | ops: thermal zone device call-backs. |
45 | .bind: bind the thermal zone device with a thermal cooling device. | 45 | .bind: bind the thermal zone device with a thermal cooling device. |
46 | .unbind: unbind the thermal zone device with a thermal cooling device. | 46 | .unbind: unbind the thermal zone device with a thermal cooling device. |
47 | .get_temp: get the current temperature of the thermal zone. | 47 | .get_temp: get the current temperature of the thermal zone. |
48 | .get_mode: get the current mode (user/kernel) of the thermal zone. | 48 | .get_mode: get the current mode (user/kernel) of the thermal zone. |
49 | "kernel" means thermal management is done in kernel. | 49 | - "kernel" means thermal management is done in kernel. |
50 | "user" will prevent kernel thermal driver actions upon trip points | 50 | - "user" will prevent kernel thermal driver actions upon trip points |
51 | so that user applications can take charge of thermal management. | 51 | so that user applications can take charge of thermal management. |
52 | .set_mode: set the mode (user/kernel) of the thermal zone. | 52 | .set_mode: set the mode (user/kernel) of the thermal zone. |
53 | .get_trip_type: get the type of certain trip point. | 53 | .get_trip_type: get the type of certain trip point. |
54 | .get_trip_temp: get the temperature above which the certain trip point | 54 | .get_trip_temp: get the temperature above which the certain trip point |
55 | will be fired. | 55 | will be fired. |
56 | 56 | ||
57 | 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz) | 57 | 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz) |
58 | 58 | ||
59 | This interface function removes the thermal zone device. | 59 | This interface function removes the thermal zone device. |
60 | It deletes the corresponding entry form /sys/class/thermal folder and unbind all | 60 | It deletes the corresponding entry form /sys/class/thermal folder and |
61 | the thermal cooling devices it uses. | 61 | unbind all the thermal cooling devices it uses. |
62 | 62 | ||
63 | 1.2 thermal cooling device interface | 63 | 1.2 thermal cooling device interface |
64 | 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name, | 64 | 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name, |
65 | void *devdata, struct thermal_cooling_device_ops *) | 65 | void *devdata, struct thermal_cooling_device_ops *) |
66 | 66 | ||
67 | This interface function adds a new thermal cooling device (fan/processor/...) to | 67 | This interface function adds a new thermal cooling device (fan/processor/...) |
68 | /sys/class/thermal/ folder as cooling_device[0-*]. | 68 | to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself |
69 | It tries to bind itself to all the thermal zone devices register at the same time. | 69 | to all the thermal zone devices register at the same time. |
70 | name: the cooling device name. | 70 | name: the cooling device name. |
71 | devdata: device private data. | 71 | devdata: device private data. |
72 | ops: thermal cooling devices call-backs. | 72 | ops: thermal cooling devices call-backs. |
73 | .get_max_state: get the Maximum throttle state of the cooling device. | 73 | .get_max_state: get the Maximum throttle state of the cooling device. |
74 | .get_cur_state: get the Current throttle state of the cooling device. | 74 | .get_cur_state: get the Current throttle state of the cooling device. |
75 | .set_cur_state: set the Current throttle state of the cooling device. | 75 | .set_cur_state: set the Current throttle state of the cooling device. |
76 | 76 | ||
77 | 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev) | 77 | 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev) |
78 | 78 | ||
79 | This interface function remove the thermal cooling device. | 79 | This interface function remove the thermal cooling device. |
80 | It deletes the corresponding entry form /sys/class/thermal folder and unbind | 80 | It deletes the corresponding entry form /sys/class/thermal folder and |
81 | itself from all the thermal zone devices using it. | 81 | unbind itself from all the thermal zone devices using it. |
82 | 82 | ||
83 | 1.3 interface for binding a thermal zone device with a thermal cooling device | 83 | 1.3 interface for binding a thermal zone device with a thermal cooling device |
84 | 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, | 84 | 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, |
85 | int trip, struct thermal_cooling_device *cdev); | 85 | int trip, struct thermal_cooling_device *cdev); |
86 | 86 | ||
87 | This interface function bind a thermal cooling device to the certain trip point | 87 | This interface function bind a thermal cooling device to the certain trip |
88 | of a thermal zone device. | 88 | point of a thermal zone device. |
89 | This function is usually called in the thermal zone device .bind callback. | 89 | This function is usually called in the thermal zone device .bind callback. |
90 | tz: the thermal zone device | 90 | tz: the thermal zone device |
91 | cdev: thermal cooling device | 91 | cdev: thermal cooling device |
92 | trip: indicates which trip point the cooling devices is associated with | 92 | trip: indicates which trip point the cooling devices is associated with |
93 | in this thermal zone. | 93 | in this thermal zone. |
94 | 94 | ||
95 | 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz, | 95 | 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz, |
96 | int trip, struct thermal_cooling_device *cdev); | 96 | int trip, struct thermal_cooling_device *cdev); |
97 | 97 | ||
98 | This interface function unbind a thermal cooling device from the certain trip point | 98 | This interface function unbind a thermal cooling device from the certain |
99 | of a thermal zone device. | 99 | trip point of a thermal zone device. This function is usually called in |
100 | This function is usually called in the thermal zone device .unbind callback. | 100 | the thermal zone device .unbind callback. |
101 | tz: the thermal zone device | 101 | tz: the thermal zone device |
102 | cdev: thermal cooling device | 102 | cdev: thermal cooling device |
103 | trip: indicates which trip point the cooling devices is associated with | 103 | trip: indicates which trip point the cooling devices is associated with |
104 | in this thermal zone. | 104 | in this thermal zone. |
105 | 105 | ||
106 | 2. sysfs attributes structure | 106 | 2. sysfs attributes structure |
107 | 107 | ||
@@ -114,153 +114,166 @@ if hwmon is compiled in or built as a module. | |||
114 | 114 | ||
115 | Thermal zone device sys I/F, created once it's registered: | 115 | Thermal zone device sys I/F, created once it's registered: |
116 | /sys/class/thermal/thermal_zone[0-*]: | 116 | /sys/class/thermal/thermal_zone[0-*]: |
117 | |-----type: Type of the thermal zone | 117 | |---type: Type of the thermal zone |
118 | |-----temp: Current temperature | 118 | |---temp: Current temperature |
119 | |-----mode: Working mode of the thermal zone | 119 | |---mode: Working mode of the thermal zone |
120 | |-----trip_point_[0-*]_temp: Trip point temperature | 120 | |---trip_point_[0-*]_temp: Trip point temperature |
121 | |-----trip_point_[0-*]_type: Trip point type | 121 | |---trip_point_[0-*]_type: Trip point type |
122 | 122 | ||
123 | Thermal cooling device sys I/F, created once it's registered: | 123 | Thermal cooling device sys I/F, created once it's registered: |
124 | /sys/class/thermal/cooling_device[0-*]: | 124 | /sys/class/thermal/cooling_device[0-*]: |
125 | |-----type : Type of the cooling device(processor/fan/...) | 125 | |---type: Type of the cooling device(processor/fan/...) |
126 | |-----max_state: Maximum cooling state of the cooling device | 126 | |---max_state: Maximum cooling state of the cooling device |
127 | |-----cur_state: Current cooling state of the cooling device | 127 | |---cur_state: Current cooling state of the cooling device |
128 | 128 | ||
129 | 129 | ||
130 | These two dynamic attributes are created/removed in pairs. | 130 | Then next two dynamic attributes are created/removed in pairs. They represent |
131 | They represent the relationship between a thermal zone and its associated cooling device. | 131 | the relationship between a thermal zone and its associated cooling device. |
132 | They are created/removed for each | 132 | They are created/removed for each successful execution of |
133 | thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device successful execution. | 133 | thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device. |
134 | 134 | ||
135 | /sys/class/thermal/thermal_zone[0-*] | 135 | /sys/class/thermal/thermal_zone[0-*]: |
136 | |-----cdev[0-*]: The [0-*]th cooling device in the current thermal zone | 136 | |---cdev[0-*]: [0-*]th cooling device in current thermal zone |
137 | |-----cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with | 137 | |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with |
138 | 138 | ||
139 | Besides the thermal zone device sysfs I/F and cooling device sysfs I/F, | 139 | Besides the thermal zone device sysfs I/F and cooling device sysfs I/F, |
140 | the generic thermal driver also creates a hwmon sysfs I/F for each _type_ of | 140 | the generic thermal driver also creates a hwmon sysfs I/F for each _type_ |
141 | thermal zone device. E.g. the generic thermal driver registers one hwmon class device | 141 | of thermal zone device. E.g. the generic thermal driver registers one hwmon |
142 | and build the associated hwmon sysfs I/F for all the registered ACPI thermal zones. | 142 | class device and build the associated hwmon sysfs I/F for all the registered |
143 | ACPI thermal zones. | ||
144 | |||
143 | /sys/class/hwmon/hwmon[0-*]: | 145 | /sys/class/hwmon/hwmon[0-*]: |
144 | |-----name: The type of the thermal zone devices. | 146 | |---name: The type of the thermal zone devices |
145 | |-----temp[1-*]_input: The current temperature of thermal zone [1-*]. | 147 | |---temp[1-*]_input: The current temperature of thermal zone [1-*] |
146 | |-----temp[1-*]_critical: The critical trip point of thermal zone [1-*]. | 148 | |---temp[1-*]_critical: The critical trip point of thermal zone [1-*] |
149 | |||
147 | Please read Documentation/hwmon/sysfs-interface for additional information. | 150 | Please read Documentation/hwmon/sysfs-interface for additional information. |
148 | 151 | ||
149 | *************************** | 152 | *************************** |
150 | * Thermal zone attributes * | 153 | * Thermal zone attributes * |
151 | *************************** | 154 | *************************** |
152 | 155 | ||
153 | type Strings which represent the thermal zone type. | 156 | type |
154 | This is given by thermal zone driver as part of registration. | 157 | Strings which represent the thermal zone type. |
155 | Eg: "acpitz" indicates it's an ACPI thermal device. | 158 | This is given by thermal zone driver as part of registration. |
156 | In order to keep it consistent with hwmon sys attribute, | 159 | E.g: "acpitz" indicates it's an ACPI thermal device. |
157 | this should be a short, lowercase string, | 160 | In order to keep it consistent with hwmon sys attribute; this should |
158 | not containing spaces nor dashes. | 161 | be a short, lowercase string, not containing spaces nor dashes. |
159 | RO | 162 | RO, Required |
160 | Required | 163 | |
161 | 164 | temp | |
162 | temp Current temperature as reported by thermal zone (sensor) | 165 | Current temperature as reported by thermal zone (sensor). |
163 | Unit: millidegree Celsius | 166 | Unit: millidegree Celsius |
164 | RO | 167 | RO, Required |
165 | Required | 168 | |
166 | 169 | mode | |
167 | mode One of the predefined values in [kernel, user] | 170 | One of the predefined values in [kernel, user]. |
168 | This file gives information about the algorithm | 171 | This file gives information about the algorithm that is currently |
169 | that is currently managing the thermal zone. | 172 | managing the thermal zone. It can be either default kernel based |
170 | It can be either default kernel based algorithm | 173 | algorithm or user space application. |
171 | or user space application. | 174 | kernel = Thermal management in kernel thermal zone driver. |
172 | RW | 175 | user = Preventing kernel thermal zone driver actions upon |
173 | Optional | 176 | trip points so that user application can take full |
174 | kernel = Thermal management in kernel thermal zone driver. | 177 | charge of the thermal management. |
175 | user = Preventing kernel thermal zone driver actions upon | 178 | RW, Optional |
176 | trip points so that user application can take full | 179 | |
177 | charge of the thermal management. | 180 | trip_point_[0-*]_temp |
178 | 181 | The temperature above which trip point will be fired. | |
179 | trip_point_[0-*]_temp The temperature above which trip point will be fired | 182 | Unit: millidegree Celsius |
180 | Unit: millidegree Celsius | 183 | RO, Optional |
181 | RO | 184 | |
182 | Optional | 185 | trip_point_[0-*]_type |
183 | 186 | Strings which indicate the type of the trip point. | |
184 | trip_point_[0-*]_type Strings which indicate the type of the trip point | 187 | E.g. it can be one of critical, hot, passive, active[0-*] for ACPI |
185 | E.g. it can be one of critical, hot, passive, | 188 | thermal zone. |
186 | active[0-*] for ACPI thermal zone. | 189 | RO, Optional |
187 | RO | 190 | |
188 | Optional | 191 | cdev[0-*] |
189 | 192 | Sysfs link to the thermal cooling device node where the sys I/F | |
190 | cdev[0-*] Sysfs link to the thermal cooling device node where the sys I/F | 193 | for cooling device throttling control represents. |
191 | for cooling device throttling control represents. | 194 | RO, Optional |
192 | RO | 195 | |
193 | Optional | 196 | cdev[0-*]_trip_point |
194 | 197 | The trip point with which cdev[0-*] is associated in this thermal | |
195 | cdev[0-*]_trip_point The trip point with which cdev[0-*] is associated in this thermal zone | 198 | zone; -1 means the cooling device is not associated with any trip |
196 | -1 means the cooling device is not associated with any trip point. | 199 | point. |
197 | RO | 200 | RO, Optional |
198 | Optional | 201 | |
199 | 202 | passive | |
200 | ****************************** | 203 | Attribute is only present for zones in which the passive cooling |
201 | * Cooling device attributes * | 204 | policy is not supported by native thermal driver. Default is zero |
202 | ****************************** | 205 | and can be set to a temperature (in millidegrees) to enable a |
203 | 206 | passive trip point for the zone. Activation is done by polling with | |
204 | type String which represents the type of device | 207 | an interval of 1 second. |
205 | eg: For generic ACPI: this should be "Fan", | 208 | Unit: millidegrees Celsius |
206 | "Processor" or "LCD" | 209 | RW, Optional |
207 | eg. For memory controller device on intel_menlow platform: | 210 | |
208 | this should be "Memory controller" | 211 | ***************************** |
209 | RO | 212 | * Cooling device attributes * |
210 | Required | 213 | ***************************** |
211 | 214 | ||
212 | max_state The maximum permissible cooling state of this cooling device. | 215 | type |
213 | RO | 216 | String which represents the type of device, e.g: |
214 | Required | 217 | - for generic ACPI: should be "Fan", "Processor" or "LCD" |
215 | 218 | - for memory controller device on intel_menlow platform: | |
216 | cur_state The current cooling state of this cooling device. | 219 | should be "Memory controller". |
217 | the value can any integer numbers between 0 and max_state, | 220 | RO, Required |
218 | cur_state == 0 means no cooling | 221 | |
219 | cur_state == max_state means the maximum cooling. | 222 | max_state |
220 | RW | 223 | The maximum permissible cooling state of this cooling device. |
221 | Required | 224 | RO, Required |
225 | |||
226 | cur_state | ||
227 | The current cooling state of this cooling device. | ||
228 | The value can any integer numbers between 0 and max_state: | ||
229 | - cur_state == 0 means no cooling | ||
230 | - cur_state == max_state means the maximum cooling. | ||
231 | RW, Required | ||
222 | 232 | ||
223 | 3. A simple implementation | 233 | 3. A simple implementation |
224 | 234 | ||
225 | ACPI thermal zone may support multiple trip points like critical/hot/passive/active. | 235 | ACPI thermal zone may support multiple trip points like critical, hot, |
226 | If an ACPI thermal zone supports critical, passive, active[0] and active[1] at the same time, | 236 | passive, active. If an ACPI thermal zone supports critical, passive, |
227 | it may register itself as a thermal_zone_device (thermal_zone1) with 4 trip points in all. | 237 | active[0] and active[1] at the same time, it may register itself as a |
228 | It has one processor and one fan, which are both registered as thermal_cooling_device. | 238 | thermal_zone_device (thermal_zone1) with 4 trip points in all. |
229 | If the processor is listed in _PSL method, and the fan is listed in _AL0 method, | 239 | It has one processor and one fan, which are both registered as |
230 | the sys I/F structure will be built like this: | 240 | thermal_cooling_device. |
241 | |||
242 | If the processor is listed in _PSL method, and the fan is listed in _AL0 | ||
243 | method, the sys I/F structure will be built like this: | ||
231 | 244 | ||
232 | /sys/class/thermal: | 245 | /sys/class/thermal: |
233 | 246 | ||
234 | |thermal_zone1: | 247 | |thermal_zone1: |
235 | |-----type: acpitz | 248 | |---type: acpitz |
236 | |-----temp: 37000 | 249 | |---temp: 37000 |
237 | |-----mode: kernel | 250 | |---mode: kernel |
238 | |-----trip_point_0_temp: 100000 | 251 | |---trip_point_0_temp: 100000 |
239 | |-----trip_point_0_type: critical | 252 | |---trip_point_0_type: critical |
240 | |-----trip_point_1_temp: 80000 | 253 | |---trip_point_1_temp: 80000 |
241 | |-----trip_point_1_type: passive | 254 | |---trip_point_1_type: passive |
242 | |-----trip_point_2_temp: 70000 | 255 | |---trip_point_2_temp: 70000 |
243 | |-----trip_point_2_type: active0 | 256 | |---trip_point_2_type: active0 |
244 | |-----trip_point_3_temp: 60000 | 257 | |---trip_point_3_temp: 60000 |
245 | |-----trip_point_3_type: active1 | 258 | |---trip_point_3_type: active1 |
246 | |-----cdev0: --->/sys/class/thermal/cooling_device0 | 259 | |---cdev0: --->/sys/class/thermal/cooling_device0 |
247 | |-----cdev0_trip_point: 1 /* cdev0 can be used for passive */ | 260 | |---cdev0_trip_point: 1 /* cdev0 can be used for passive */ |
248 | |-----cdev1: --->/sys/class/thermal/cooling_device3 | 261 | |---cdev1: --->/sys/class/thermal/cooling_device3 |
249 | |-----cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/ | 262 | |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/ |
250 | 263 | ||
251 | |cooling_device0: | 264 | |cooling_device0: |
252 | |-----type: Processor | 265 | |---type: Processor |
253 | |-----max_state: 8 | 266 | |---max_state: 8 |
254 | |-----cur_state: 0 | 267 | |---cur_state: 0 |
255 | 268 | ||
256 | |cooling_device3: | 269 | |cooling_device3: |
257 | |-----type: Fan | 270 | |---type: Fan |
258 | |-----max_state: 2 | 271 | |---max_state: 2 |
259 | |-----cur_state: 0 | 272 | |---cur_state: 0 |
260 | 273 | ||
261 | /sys/class/hwmon: | 274 | /sys/class/hwmon: |
262 | 275 | ||
263 | |hwmon0: | 276 | |hwmon0: |
264 | |-----name: acpitz | 277 | |---name: acpitz |
265 | |-----temp1_input: 37000 | 278 | |---temp1_input: 37000 |
266 | |-----temp1_crit: 100000 | 279 | |---temp1_crit: 100000 |
diff --git a/Documentation/vm/page-types.c b/Documentation/vm/page-types.c index 3ec4f2a22585..4793c6aac733 100644 --- a/Documentation/vm/page-types.c +++ b/Documentation/vm/page-types.c | |||
@@ -218,7 +218,7 @@ static void fatal(const char *x, ...) | |||
218 | exit(EXIT_FAILURE); | 218 | exit(EXIT_FAILURE); |
219 | } | 219 | } |
220 | 220 | ||
221 | int checked_open(const char *pathname, int flags) | 221 | static int checked_open(const char *pathname, int flags) |
222 | { | 222 | { |
223 | int fd = open(pathname, flags); | 223 | int fd = open(pathname, flags); |
224 | 224 | ||