aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/f71882fg12
1 files changed, 8 insertions, 4 deletions
diff --git a/Documentation/hwmon/f71882fg b/Documentation/hwmon/f71882fg
index a8321267b5b6..bee4c30bc1e2 100644
--- a/Documentation/hwmon/f71882fg
+++ b/Documentation/hwmon/f71882fg
@@ -2,14 +2,18 @@ Kernel driver f71882fg
2====================== 2======================
3 3
4Supported chips: 4Supported chips:
5 * Fintek F71882FG and F71883FG 5 * Fintek F71858FG
6 Prefix: 'f71882fg' 6 Prefix: 'f71858fg'
7 Addresses scanned: none, address read from Super I/O config space 7 Addresses scanned: none, address read from Super I/O config space
8 Datasheet: Available from the Fintek website 8 Datasheet: Available from the Fintek website
9 * Fintek F71862FG and F71863FG 9 * Fintek F71862FG and F71863FG
10 Prefix: 'f71862fg' 10 Prefix: 'f71862fg'
11 Addresses scanned: none, address read from Super I/O config space 11 Addresses scanned: none, address read from Super I/O config space
12 Datasheet: Available from the Fintek website 12 Datasheet: Available from the Fintek website
13 * Fintek F71882FG and F71883FG
14 Prefix: 'f71882fg'
15 Addresses scanned: none, address read from Super I/O config space
16 Datasheet: Available from the Fintek website
13 * Fintek F8000 17 * Fintek F8000
14 Prefix: 'f8000' 18 Prefix: 'f8000'
15 Addresses scanned: none, address read from Super I/O config space 19 Addresses scanned: none, address read from Super I/O config space
@@ -66,13 +70,13 @@ printed when loading the driver.
66 70
67Three different fan control modes are supported; the mode number is written 71Three different fan control modes are supported; the mode number is written
68to the pwm#_enable file. Note that not all modes are supported on all 72to the pwm#_enable file. Note that not all modes are supported on all
69chips, and some modes may only be available in RPM / PWM mode on the F8000. 73chips, and some modes may only be available in RPM / PWM mode.
70Writing an unsupported mode will result in an invalid parameter error. 74Writing an unsupported mode will result in an invalid parameter error.
71 75
72* 1: Manual mode 76* 1: Manual mode
73 You ask for a specific PWM duty cycle / DC voltage or a specific % of 77 You ask for a specific PWM duty cycle / DC voltage or a specific % of
74 fan#_full_speed by writing to the pwm# file. This mode is only 78 fan#_full_speed by writing to the pwm# file. This mode is only
75 available on the F8000 if the fan channel is in RPM mode. 79 available on the F71858FG / F8000 if the fan channel is in RPM mode.
76 80
77* 2: Normal auto mode 81* 2: Normal auto mode
78 You can define a number of temperature/fan speed trip points, which % the 82 You can define a number of temperature/fan speed trip points, which % the