diff options
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/thermal/sysfs-api.txt | 13 |
1 files changed, 13 insertions, 0 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index 526d4b90d6c1..6859661c9d31 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt | |||
@@ -55,6 +55,8 @@ temperature) and throttle appropriate devices. | |||
55 | .get_trip_type: get the type of certain trip point. | 55 | .get_trip_type: get the type of certain trip point. |
56 | .get_trip_temp: get the temperature above which the certain trip point | 56 | .get_trip_temp: get the temperature above which the certain trip point |
57 | will be fired. | 57 | will be fired. |
58 | .set_emul_temp: set the emulation temperature which helps in debugging | ||
59 | different threshold temperature points. | ||
58 | 60 | ||
59 | 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz) | 61 | 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz) |
60 | 62 | ||
@@ -153,6 +155,7 @@ Thermal zone device sys I/F, created once it's registered: | |||
153 | |---trip_point_[0-*]_temp: Trip point temperature | 155 | |---trip_point_[0-*]_temp: Trip point temperature |
154 | |---trip_point_[0-*]_type: Trip point type | 156 | |---trip_point_[0-*]_type: Trip point type |
155 | |---trip_point_[0-*]_hyst: Hysteresis value for this trip point | 157 | |---trip_point_[0-*]_hyst: Hysteresis value for this trip point |
158 | |---emul_temp: Emulated temperature set node | ||
156 | 159 | ||
157 | Thermal cooling device sys I/F, created once it's registered: | 160 | Thermal cooling device sys I/F, created once it's registered: |
158 | /sys/class/thermal/cooling_device[0-*]: | 161 | /sys/class/thermal/cooling_device[0-*]: |
@@ -252,6 +255,16 @@ passive | |||
252 | Valid values: 0 (disabled) or greater than 1000 | 255 | Valid values: 0 (disabled) or greater than 1000 |
253 | RW, Optional | 256 | RW, Optional |
254 | 257 | ||
258 | emul_temp | ||
259 | Interface to set the emulated temperature method in thermal zone | ||
260 | (sensor). After setting this temperature, the thermal zone may pass | ||
261 | this temperature to platform emulation function if registered or | ||
262 | cache it locally. This is useful in debugging different temperature | ||
263 | threshold and its associated cooling action. This is write only node | ||
264 | and writing 0 on this node should disable emulation. | ||
265 | Unit: millidegree Celsius | ||
266 | WO, Optional | ||
267 | |||
255 | ***************************** | 268 | ***************************** |
256 | * Cooling device attributes * | 269 | * Cooling device attributes * |
257 | ***************************** | 270 | ***************************** |