diff options
Diffstat (limited to 'Documentation/thermal/sysfs-api.txt')
-rw-r--r-- | Documentation/thermal/sysfs-api.txt | 22 |
1 files changed, 11 insertions, 11 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index ba9c2da5a8c2..d9f28be75403 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt | |||
@@ -143,10 +143,10 @@ type Strings which represent the thermal zone type. | |||
143 | This is given by thermal zone driver as part of registration. | 143 | This is given by thermal zone driver as part of registration. |
144 | Eg: "ACPI thermal zone" indicates it's a ACPI thermal device | 144 | Eg: "ACPI thermal zone" indicates it's a ACPI thermal device |
145 | RO | 145 | RO |
146 | Optional | 146 | Required |
147 | 147 | ||
148 | temp Current temperature as reported by thermal zone (sensor) | 148 | temp Current temperature as reported by thermal zone (sensor) |
149 | Unit: degree Celsius | 149 | Unit: millidegree Celsius |
150 | RO | 150 | RO |
151 | Required | 151 | Required |
152 | 152 | ||
@@ -163,7 +163,7 @@ mode One of the predefined values in [kernel, user] | |||
163 | charge of the thermal management. | 163 | charge of the thermal management. |
164 | 164 | ||
165 | trip_point_[0-*]_temp The temperature above which trip point will be fired | 165 | trip_point_[0-*]_temp The temperature above which trip point will be fired |
166 | Unit: degree Celsius | 166 | Unit: millidegree Celsius |
167 | RO | 167 | RO |
168 | Optional | 168 | Optional |
169 | 169 | ||
@@ -193,7 +193,7 @@ type String which represents the type of device | |||
193 | eg. For memory controller device on intel_menlow platform: | 193 | eg. For memory controller device on intel_menlow platform: |
194 | this should be "Memory controller" | 194 | this should be "Memory controller" |
195 | RO | 195 | RO |
196 | Optional | 196 | Required |
197 | 197 | ||
198 | max_state The maximum permissible cooling state of this cooling device. | 198 | max_state The maximum permissible cooling state of this cooling device. |
199 | RO | 199 | RO |
@@ -219,16 +219,16 @@ the sys I/F structure will be built like this: | |||
219 | 219 | ||
220 | |thermal_zone1: | 220 | |thermal_zone1: |
221 | |-----type: ACPI thermal zone | 221 | |-----type: ACPI thermal zone |
222 | |-----temp: 37 | 222 | |-----temp: 37000 |
223 | |-----mode: kernel | 223 | |-----mode: kernel |
224 | |-----trip_point_0_temp: 100 | 224 | |-----trip_point_0_temp: 100000 |
225 | |-----trip_point_0_type: critical | 225 | |-----trip_point_0_type: critical |
226 | |-----trip_point_1_temp: 80 | 226 | |-----trip_point_1_temp: 80000 |
227 | |-----trip_point_1_type: passive | 227 | |-----trip_point_1_type: passive |
228 | |-----trip_point_2_temp: 70 | 228 | |-----trip_point_2_temp: 70000 |
229 | |-----trip_point_2_type: active[0] | 229 | |-----trip_point_2_type: active0 |
230 | |-----trip_point_3_temp: 60 | 230 | |-----trip_point_3_temp: 60000 |
231 | |-----trip_point_3_type: active[1] | 231 | |-----trip_point_3_type: active1 |
232 | |-----cdev0: --->/sys/class/thermal/cooling_device0 | 232 | |-----cdev0: --->/sys/class/thermal/cooling_device0 |
233 | |-----cdev0_trip_point: 1 /* cdev0 can be used for passive */ | 233 | |-----cdev0_trip_point: 1 /* cdev0 can be used for passive */ |
234 | |-----cdev1: --->/sys/class/thermal/cooling_device3 | 234 | |-----cdev1: --->/sys/class/thermal/cooling_device3 |