1This describes the interface for the ADT7475 driver:
2
3(there are 4 fans, numbered fan1 to fan4):
4
5fanX_input Read the current speed of the fan (in RPMs)
6fanX_min Read/write the minimum speed of the fan. Dropping
7 below this sets an alarm.
8
9(there are three PWMs, numbered pwm1 to pwm3):
10
11pwmX Read/write the current duty cycle of the PWM. Writes
12 only have effect when auto mode is turned off (see
13 below). Range is 0 - 255.
14
15pwmX_enable Fan speed control method:
16
17 0 - No control (fan at full speed)
18 1 - Manual fan speed control (using pwm[1-*])
19 2 - Automatic fan speed control
20
21pwmX_auto_channels_temp Select which channels affect this PWM
22
23 1 - TEMP1 controls PWM
24 2 - TEMP2 controls PWM
25 4 - TEMP3 controls PWM
26 6 - TEMP2 and TEMP3 control PWM
27 7 - All three inputs control PWM
28
29pwmX_freq Read/write the PWM frequency in Hz. The number
30 should be one of the following:
31
32 11 Hz
33 14 Hz
34 22 Hz
35 29 Hz
36 35 Hz
37 44 Hz
38 58 Hz
39 88 Hz
40
41pwmX_auto_point1_pwm Read/write the minimum PWM duty cycle in automatic mode
42
43pwmX_auto_point2_pwm Read/write the maximum PWM duty cycle in automatic mode
44
45(there are three temperature settings numbered temp1 to temp3):
46
47tempX_input Read the current temperature. The value is in milli
48 degrees of Celsius.
49
50tempX_max Read/write the upper temperature limit - exceeding this
51 will cause an alarm.
52
53tempX_min Read/write the lower temperature limit - exceeding this
54 will cause an alarm.
55
56tempX_offset Read/write the temperature adjustment offset
57
58tempX_crit Read/write the THERM limit for remote1.
59
60tempX_crit_hyst Set the temperature value below crit where the
61 fans will stay on - this helps drive the temperature
62 low enough so it doesn't stay near the edge and
63 cause THERM to keep tripping.
64
65tempX_auto_point1_temp Read/write the minimum temperature where the fans will
66 turn on in automatic mode.
67
68tempX_auto_point2_temp Read/write the maximum temperature over which the fans
69 will run in automatic mode. tempX_auto_point1_temp
70 and tempX_auto_point2_temp together define the
71 range of automatic control.
72
73tempX_alarm Read a 1 if the max/min alarm is set
74tempX_fault Read a 1 if either temp1 or temp3 diode has a fault
75
76(There are two voltage settings, in1 and in2):
77
78inX_input Read the current voltage on VCC. Value is in
79 millivolts.
80
81inX_min read/write the minimum voltage limit.
82 Dropping below this causes an alarm.
83
84inX_max read/write the maximum voltage limit.
85 Exceeding this causes an alarm.
86
87inX_alarm Read a 1 if the max/min alarm is set.