diff options
Diffstat (limited to 'Documentation/hwmon/sysfs-interface')
| -rw-r--r-- | Documentation/hwmon/sysfs-interface | 40 |
1 files changed, 33 insertions, 7 deletions
diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface index 645699010551..5997b5efc1cb 100644 --- a/Documentation/hwmon/sysfs-interface +++ b/Documentation/hwmon/sysfs-interface | |||
| @@ -384,10 +384,20 @@ curr[1-*]_min Current min value. | |||
| 384 | Unit: milliampere | 384 | Unit: milliampere |
| 385 | RW | 385 | RW |
| 386 | 386 | ||
| 387 | curr[1-*]_lcrit Current critical low value | ||
| 388 | Unit: milliampere | ||
| 389 | RW | ||
| 390 | |||
| 391 | curr[1-*]_crit Current critical high value. | ||
| 392 | Unit: milliampere | ||
| 393 | RW | ||
| 394 | |||
| 387 | curr[1-*]_input Current input value | 395 | curr[1-*]_input Current input value |
| 388 | Unit: milliampere | 396 | Unit: milliampere |
| 389 | RO | 397 | RO |
| 390 | 398 | ||
| 399 | Also see the Alarms section for status flags associated with currents. | ||
| 400 | |||
| 391 | ********* | 401 | ********* |
| 392 | * Power * | 402 | * Power * |
| 393 | ********* | 403 | ********* |
| @@ -450,13 +460,6 @@ power[1-*]_accuracy Accuracy of the power meter. | |||
| 450 | Unit: Percent | 460 | Unit: Percent |
| 451 | RO | 461 | RO |
| 452 | 462 | ||
| 453 | power[1-*]_alarm 1 if the system is drawing more power than the | ||
| 454 | cap allows; 0 otherwise. A poll notification is | ||
| 455 | sent to this file when the power use exceeds the | ||
| 456 | cap. This file only appears if the cap is known | ||
| 457 | to be enforced by hardware. | ||
| 458 | RO | ||
| 459 | |||
| 460 | power[1-*]_cap If power use rises above this limit, the | 463 | power[1-*]_cap If power use rises above this limit, the |
| 461 | system should take action to reduce power use. | 464 | system should take action to reduce power use. |
| 462 | A poll notification is sent to this file if the | 465 | A poll notification is sent to this file if the |
| @@ -479,6 +482,20 @@ power[1-*]_cap_min Minimum cap that can be set. | |||
| 479 | Unit: microWatt | 482 | Unit: microWatt |
| 480 | RO | 483 | RO |
| 481 | 484 | ||
| 485 | power[1-*]_max Maximum power. | ||
| 486 | Unit: microWatt | ||
| 487 | RW | ||
| 488 | |||
| 489 | power[1-*]_crit Critical maximum power. | ||
| 490 | If power rises to or above this limit, the | ||
| 491 | system is expected take drastic action to reduce | ||
| 492 | power consumption, such as a system shutdown or | ||
| 493 | a forced powerdown of some devices. | ||
| 494 | Unit: microWatt | ||
| 495 | RW | ||
| 496 | |||
| 497 | Also see the Alarms section for status flags associated with power readings. | ||
| 498 | |||
| 482 | ********** | 499 | ********** |
| 483 | * Energy * | 500 | * Energy * |
| 484 | ********** | 501 | ********** |
| @@ -501,6 +518,7 @@ implementation. | |||
| 501 | 518 | ||
| 502 | in[0-*]_alarm | 519 | in[0-*]_alarm |
| 503 | curr[1-*]_alarm | 520 | curr[1-*]_alarm |
| 521 | power[1-*]_alarm | ||
| 504 | fan[1-*]_alarm | 522 | fan[1-*]_alarm |
| 505 | temp[1-*]_alarm | 523 | temp[1-*]_alarm |
| 506 | Channel alarm | 524 | Channel alarm |
| @@ -512,12 +530,20 @@ OR | |||
| 512 | 530 | ||
| 513 | in[0-*]_min_alarm | 531 | in[0-*]_min_alarm |
| 514 | in[0-*]_max_alarm | 532 | in[0-*]_max_alarm |
| 533 | in[0-*]_lcrit_alarm | ||
| 534 | in[0-*]_crit_alarm | ||
| 515 | curr[1-*]_min_alarm | 535 | curr[1-*]_min_alarm |
| 516 | curr[1-*]_max_alarm | 536 | curr[1-*]_max_alarm |
| 537 | curr[1-*]_lcrit_alarm | ||
| 538 | curr[1-*]_crit_alarm | ||
| 539 | power[1-*]_cap_alarm | ||
| 540 | power[1-*]_max_alarm | ||
| 541 | power[1-*]_crit_alarm | ||
| 517 | fan[1-*]_min_alarm | 542 | fan[1-*]_min_alarm |
| 518 | fan[1-*]_max_alarm | 543 | fan[1-*]_max_alarm |
| 519 | temp[1-*]_min_alarm | 544 | temp[1-*]_min_alarm |
| 520 | temp[1-*]_max_alarm | 545 | temp[1-*]_max_alarm |
| 546 | temp[1-*]_lcrit_alarm | ||
| 521 | temp[1-*]_crit_alarm | 547 | temp[1-*]_crit_alarm |
| 522 | temp[1-*]_emergency_alarm | 548 | temp[1-*]_emergency_alarm |
| 523 | Limit alarm | 549 | Limit alarm |