diff options
Diffstat (limited to 'Documentation/ABI')
-rw-r--r-- | Documentation/ABI/testing/sysfs-class-regulator | 57 |
1 files changed, 48 insertions, 9 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-regulator b/Documentation/ABI/testing/sysfs-class-regulator index 873ef1fc1569..e091fa873792 100644 --- a/Documentation/ABI/testing/sysfs-class-regulator +++ b/Documentation/ABI/testing/sysfs-class-regulator | |||
@@ -4,8 +4,8 @@ KernelVersion: 2.6.26 | |||
4 | Contact: Liam Girdwood <lrg@slimlogic.co.uk> | 4 | Contact: Liam Girdwood <lrg@slimlogic.co.uk> |
5 | Description: | 5 | Description: |
6 | Some regulator directories will contain a field called | 6 | Some regulator directories will contain a field called |
7 | state. This reports the regulator enable status, for | 7 | state. This reports the regulator enable control, for |
8 | regulators which can report that value. | 8 | regulators which can report that input value. |
9 | 9 | ||
10 | This will be one of the following strings: | 10 | This will be one of the following strings: |
11 | 11 | ||
@@ -14,16 +14,54 @@ Description: | |||
14 | 'unknown' | 14 | 'unknown' |
15 | 15 | ||
16 | 'enabled' means the regulator output is ON and is supplying | 16 | 'enabled' means the regulator output is ON and is supplying |
17 | power to the system. | 17 | power to the system (assuming no error prevents it). |
18 | 18 | ||
19 | 'disabled' means the regulator output is OFF and is not | 19 | 'disabled' means the regulator output is OFF and is not |
20 | supplying power to the system.. | 20 | supplying power to the system (unless some non-Linux |
21 | control has enabled it). | ||
21 | 22 | ||
22 | 'unknown' means software cannot determine the state, or | 23 | 'unknown' means software cannot determine the state, or |
23 | the reported state is invalid. | 24 | the reported state is invalid. |
24 | 25 | ||
25 | NOTE: this field can be used in conjunction with microvolts | 26 | NOTE: this field can be used in conjunction with microvolts |
26 | and microamps to determine regulator output levels. | 27 | or microamps to determine configured regulator output levels. |
28 | |||
29 | |||
30 | What: /sys/class/regulator/.../status | ||
31 | Description: | ||
32 | Some regulator directories will contain a field called | ||
33 | "status". This reports the current regulator status, for | ||
34 | regulators which can report that output value. | ||
35 | |||
36 | This will be one of the following strings: | ||
37 | |||
38 | off | ||
39 | on | ||
40 | error | ||
41 | fast | ||
42 | normal | ||
43 | idle | ||
44 | standby | ||
45 | |||
46 | "off" means the regulator is not supplying power to the | ||
47 | system. | ||
48 | |||
49 | "on" means the regulator is supplying power to the system, | ||
50 | and the regulator can't report a detailed operation mode. | ||
51 | |||
52 | "error" indicates an out-of-regulation status such as being | ||
53 | disabled due to thermal shutdown, or voltage being unstable | ||
54 | because of problems with the input power supply. | ||
55 | |||
56 | "fast", "normal", "idle", and "standby" are all detailed | ||
57 | regulator operation modes (described elsewhere). They | ||
58 | imply "on", but provide more detail. | ||
59 | |||
60 | Note that regulator status is a function of many inputs, | ||
61 | not limited to control inputs from Linux. For example, | ||
62 | the actual load presented may trigger "error" status; or | ||
63 | a regulator may be enabled by another user, even though | ||
64 | Linux did not enable it. | ||
27 | 65 | ||
28 | 66 | ||
29 | What: /sys/class/regulator/.../type | 67 | What: /sys/class/regulator/.../type |
@@ -58,7 +96,7 @@ Description: | |||
58 | Some regulator directories will contain a field called | 96 | Some regulator directories will contain a field called |
59 | microvolts. This holds the regulator output voltage setting | 97 | microvolts. This holds the regulator output voltage setting |
60 | measured in microvolts (i.e. E-6 Volts), for regulators | 98 | measured in microvolts (i.e. E-6 Volts), for regulators |
61 | which can report that voltage. | 99 | which can report the control input for voltage. |
62 | 100 | ||
63 | NOTE: This value should not be used to determine the regulator | 101 | NOTE: This value should not be used to determine the regulator |
64 | output voltage level as this value is the same regardless of | 102 | output voltage level as this value is the same regardless of |
@@ -73,7 +111,7 @@ Description: | |||
73 | Some regulator directories will contain a field called | 111 | Some regulator directories will contain a field called |
74 | microamps. This holds the regulator output current limit | 112 | microamps. This holds the regulator output current limit |
75 | setting measured in microamps (i.e. E-6 Amps), for regulators | 113 | setting measured in microamps (i.e. E-6 Amps), for regulators |
76 | which can report that current. | 114 | which can report the control input for a current limit. |
77 | 115 | ||
78 | NOTE: This value should not be used to determine the regulator | 116 | NOTE: This value should not be used to determine the regulator |
79 | output current level as this value is the same regardless of | 117 | output current level as this value is the same regardless of |
@@ -87,7 +125,7 @@ Contact: Liam Girdwood <lrg@slimlogic.co.uk> | |||
87 | Description: | 125 | Description: |
88 | Some regulator directories will contain a field called | 126 | Some regulator directories will contain a field called |
89 | opmode. This holds the current regulator operating mode, | 127 | opmode. This holds the current regulator operating mode, |
90 | for regulators which can report it. | 128 | for regulators which can report that control input value. |
91 | 129 | ||
92 | The opmode value can be one of the following strings: | 130 | The opmode value can be one of the following strings: |
93 | 131 | ||
@@ -101,7 +139,8 @@ Description: | |||
101 | 139 | ||
102 | NOTE: This value should not be used to determine the regulator | 140 | NOTE: This value should not be used to determine the regulator |
103 | output operating mode as this value is the same regardless of | 141 | output operating mode as this value is the same regardless of |
104 | whether the regulator is enabled or disabled. | 142 | whether the regulator is enabled or disabled. A "status" |
143 | attribute may be available to determine the actual mode. | ||
105 | 144 | ||
106 | 145 | ||
107 | What: /sys/class/regulator/.../min_microvolts | 146 | What: /sys/class/regulator/.../min_microvolts |