diff options
-rw-r--r-- | Documentation/block/cfq-iosched.txt | 45 | ||||
-rw-r--r-- | Documentation/cgroups/blkio-controller.txt | 28 |
2 files changed, 73 insertions, 0 deletions
diff --git a/Documentation/block/cfq-iosched.txt b/Documentation/block/cfq-iosched.txt new file mode 100644 index 000000000000..e578feed6d81 --- /dev/null +++ b/Documentation/block/cfq-iosched.txt | |||
@@ -0,0 +1,45 @@ | |||
1 | CFQ ioscheduler tunables | ||
2 | ======================== | ||
3 | |||
4 | slice_idle | ||
5 | ---------- | ||
6 | This specifies how long CFQ should idle for next request on certain cfq queues | ||
7 | (for sequential workloads) and service trees (for random workloads) before | ||
8 | queue is expired and CFQ selects next queue to dispatch from. | ||
9 | |||
10 | By default slice_idle is a non-zero value. That means by default we idle on | ||
11 | queues/service trees. This can be very helpful on highly seeky media like | ||
12 | single spindle SATA/SAS disks where we can cut down on overall number of | ||
13 | seeks and see improved throughput. | ||
14 | |||
15 | Setting slice_idle to 0 will remove all the idling on queues/service tree | ||
16 | level and one should see an overall improved throughput on faster storage | ||
17 | devices like multiple SATA/SAS disks in hardware RAID configuration. The down | ||
18 | side is that isolation provided from WRITES also goes down and notion of | ||
19 | IO priority becomes weaker. | ||
20 | |||
21 | So depending on storage and workload, it might be useful to set slice_idle=0. | ||
22 | In general I think for SATA/SAS disks and software RAID of SATA/SAS disks | ||
23 | keeping slice_idle enabled should be useful. For any configurations where | ||
24 | there are multiple spindles behind single LUN (Host based hardware RAID | ||
25 | controller or for storage arrays), setting slice_idle=0 might end up in better | ||
26 | throughput and acceptable latencies. | ||
27 | |||
28 | CFQ IOPS Mode for group scheduling | ||
29 | =================================== | ||
30 | Basic CFQ design is to provide priority based time slices. Higher priority | ||
31 | process gets bigger time slice and lower priority process gets smaller time | ||
32 | slice. Measuring time becomes harder if storage is fast and supports NCQ and | ||
33 | it would be better to dispatch multiple requests from multiple cfq queues in | ||
34 | request queue at a time. In such scenario, it is not possible to measure time | ||
35 | consumed by single queue accurately. | ||
36 | |||
37 | What is possible though is to measure number of requests dispatched from a | ||
38 | single queue and also allow dispatch from multiple cfq queue at the same time. | ||
39 | This effectively becomes the fairness in terms of IOPS (IO operations per | ||
40 | second). | ||
41 | |||
42 | If one sets slice_idle=0 and if storage supports NCQ, CFQ internally switches | ||
43 | to IOPS mode and starts providing fairness in terms of number of requests | ||
44 | dispatched. Note that this mode switching takes effect only for group | ||
45 | scheduling. For non-cgroup users nothing should change. | ||
diff --git a/Documentation/cgroups/blkio-controller.txt b/Documentation/cgroups/blkio-controller.txt index 48e0b21b0059..6919d62591d9 100644 --- a/Documentation/cgroups/blkio-controller.txt +++ b/Documentation/cgroups/blkio-controller.txt | |||
@@ -217,6 +217,7 @@ Details of cgroup files | |||
217 | CFQ sysfs tunable | 217 | CFQ sysfs tunable |
218 | ================= | 218 | ================= |
219 | /sys/block/<disk>/queue/iosched/group_isolation | 219 | /sys/block/<disk>/queue/iosched/group_isolation |
220 | ----------------------------------------------- | ||
220 | 221 | ||
221 | If group_isolation=1, it provides stronger isolation between groups at the | 222 | If group_isolation=1, it provides stronger isolation between groups at the |
222 | expense of throughput. By default group_isolation is 0. In general that | 223 | expense of throughput. By default group_isolation is 0. In general that |
@@ -243,6 +244,33 @@ By default one should run with group_isolation=0. If that is not sufficient | |||
243 | and one wants stronger isolation between groups, then set group_isolation=1 | 244 | and one wants stronger isolation between groups, then set group_isolation=1 |
244 | but this will come at cost of reduced throughput. | 245 | but this will come at cost of reduced throughput. |
245 | 246 | ||
247 | /sys/block/<disk>/queue/iosched/slice_idle | ||
248 | ------------------------------------------ | ||
249 | On a faster hardware CFQ can be slow, especially with sequential workload. | ||
250 | This happens because CFQ idles on a single queue and single queue might not | ||
251 | drive deeper request queue depths to keep the storage busy. In such scenarios | ||
252 | one can try setting slice_idle=0 and that would switch CFQ to IOPS | ||
253 | (IO operations per second) mode on NCQ supporting hardware. | ||
254 | |||
255 | That means CFQ will not idle between cfq queues of a cfq group and hence be | ||
256 | able to driver higher queue depth and achieve better throughput. That also | ||
257 | means that cfq provides fairness among groups in terms of IOPS and not in | ||
258 | terms of disk time. | ||
259 | |||
260 | /sys/block/<disk>/queue/iosched/group_idle | ||
261 | ------------------------------------------ | ||
262 | If one disables idling on individual cfq queues and cfq service trees by | ||
263 | setting slice_idle=0, group_idle kicks in. That means CFQ will still idle | ||
264 | on the group in an attempt to provide fairness among groups. | ||
265 | |||
266 | By default group_idle is same as slice_idle and does not do anything if | ||
267 | slice_idle is enabled. | ||
268 | |||
269 | One can experience an overall throughput drop if you have created multiple | ||
270 | groups and put applications in that group which are not driving enough | ||
271 | IO to keep disk busy. In that case set group_idle=0, and CFQ will not idle | ||
272 | on individual groups and throughput should improve. | ||
273 | |||
246 | What works | 274 | What works |
247 | ========== | 275 | ========== |
248 | - Currently only sync IO queues are support. All the buffered writes are | 276 | - Currently only sync IO queues are support. All the buffered writes are |