aboutsummaryrefslogtreecommitdiffstats
path: root/samples
diff options
context:
space:
mode:
authorAaro Koskinen <aaro.koskinen@iki.fi>2013-07-20 20:30:11 -0400
committerBenjamin Herrenschmidt <benh@kernel.crashing.org>2013-07-31 23:11:47 -0400
commitfe956a1d4081ce1a959f87df397a15e252201f10 (patch)
tree236b73915ded48c90f525223c541d0460ba5c03c /samples
parent3be7db6ab45b21345386d1a466da133b19cde5e4 (diff)
powerpc/windfarm: Fix noisy slots-fan on Xserve (rm31)
slots-fan on G5 Xserve is always running at full speed with windfarm_rm31 driver, resulting in a very high acoustic noise level. It seems the fan parameters are incorrect, and have been copied from the Drive Bay fan (RPM, not present on rm31) of the legacy therm_pm72 driver. This patch changes the parameters to match the Slots fan (PWM) of therm_pm72. With the patch, slots-fan speed drops from 99% to 19% during normal use, and slots-temp settle to ~42'C. Signed-off-by: Aaro Koskinen <aaro.koskinen@iki.fi> CC: <stable@vger.kernel.org> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
Diffstat (limited to 'samples')
0 files changed, 0 insertions, 0 deletions