diff options
author | Joel Becker <joel.becker@oracle.com> | 2008-11-13 17:49:11 -0500 |
---|---|---|
committer | Mark Fasheh <mfasheh@suse.com> | 2009-01-05 11:36:52 -0500 |
commit | b657c95c11088d77fc1bfc9c84d940f778bf9d12 (patch) | |
tree | 7e52e73aabbdbc55f644ad26735edc25a652ac32 /fs/ocfs2/dir.c | |
parent | a68979b857283daf4acc405e476dcc8812a3ff2b (diff) |
ocfs2: Wrap inode block reads in a dedicated function.
The ocfs2 code currently reads inodes off disk with a simple
ocfs2_read_block() call. Each place that does this has a different set
of sanity checks it performs. Some check only the signature. A couple
validate the block number (the block read vs di->i_blkno). A couple
others check for VALID_FL. Only one place validates i_fs_generation. A
couple check nothing. Even when an error is found, they don't all do
the same thing.
We wrap inode reading into ocfs2_read_inode_block(). This will validate
all the above fields, going readonly if they are invalid (they never
should be). ocfs2_read_inode_block_full() is provided for the places
that want to pass read_block flags. Every caller is passing a struct
inode with a valid ip_blkno, so we don't need a separate blkno argument
either.
We will remove the validation checks from the rest of the code in a
later commit, as they are no longer necessary.
Signed-off-by: Joel Becker <joel.becker@oracle.com>
Signed-off-by: Mark Fasheh <mfasheh@suse.com>
Diffstat (limited to 'fs/ocfs2/dir.c')
-rw-r--r-- | fs/ocfs2/dir.c | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/fs/ocfs2/dir.c b/fs/ocfs2/dir.c index 026e6eb85187..5777045f1a67 100644 --- a/fs/ocfs2/dir.c +++ b/fs/ocfs2/dir.c | |||
@@ -231,7 +231,7 @@ static struct buffer_head *ocfs2_find_entry_id(const char *name, | |||
231 | struct ocfs2_dinode *di; | 231 | struct ocfs2_dinode *di; |
232 | struct ocfs2_inline_data *data; | 232 | struct ocfs2_inline_data *data; |
233 | 233 | ||
234 | ret = ocfs2_read_block(dir, OCFS2_I(dir)->ip_blkno, &di_bh); | 234 | ret = ocfs2_read_inode_block(dir, &di_bh); |
235 | if (ret) { | 235 | if (ret) { |
236 | mlog_errno(ret); | 236 | mlog_errno(ret); |
237 | goto out; | 237 | goto out; |
@@ -458,7 +458,7 @@ static inline int ocfs2_delete_entry_id(handle_t *handle, | |||
458 | struct ocfs2_dinode *di; | 458 | struct ocfs2_dinode *di; |
459 | struct ocfs2_inline_data *data; | 459 | struct ocfs2_inline_data *data; |
460 | 460 | ||
461 | ret = ocfs2_read_block(dir, OCFS2_I(dir)->ip_blkno, &di_bh); | 461 | ret = ocfs2_read_inode_block(dir, &di_bh); |
462 | if (ret) { | 462 | if (ret) { |
463 | mlog_errno(ret); | 463 | mlog_errno(ret); |
464 | goto out; | 464 | goto out; |
@@ -636,7 +636,7 @@ static int ocfs2_dir_foreach_blk_id(struct inode *inode, | |||
636 | struct ocfs2_inline_data *data; | 636 | struct ocfs2_inline_data *data; |
637 | struct ocfs2_dir_entry *de; | 637 | struct ocfs2_dir_entry *de; |
638 | 638 | ||
639 | ret = ocfs2_read_block(inode, OCFS2_I(inode)->ip_blkno, &di_bh); | 639 | ret = ocfs2_read_inode_block(inode, &di_bh); |
640 | if (ret) { | 640 | if (ret) { |
641 | mlog(ML_ERROR, "Unable to read inode block for dir %llu\n", | 641 | mlog(ML_ERROR, "Unable to read inode block for dir %llu\n", |
642 | (unsigned long long)OCFS2_I(inode)->ip_blkno); | 642 | (unsigned long long)OCFS2_I(inode)->ip_blkno); |