aboutsummaryrefslogtreecommitdiffstats
path: root/drivers
diff options
context:
space:
mode:
authorEliezer Tamir <eliezert@broadcom.com>2008-03-23 06:07:45 -0400
committerDavid S. Miller <davem@davemloft.net>2008-03-23 06:07:45 -0400
commit2572c149a2f52232ce690ddb9c6fd0c90ffd61cd (patch)
treeafad1bbdd52a15b26c3075b5184f989dbc4645ee /drivers
parent53a6201fdfa04accc91ea1a7accce8e8bc37ef8e (diff)
BNX2X: prevent ethtool from setting port type
On 10GBaseT boards setting the type to TP will cause the driver to try to configure 1GBaseT. Since there are currently no boards that support setting of the port type, disable this for now. Signed-off-by: Eliezer Tamir <eliezert@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/net/bnx2x.c36
1 files changed, 2 insertions, 34 deletions
diff --git a/drivers/net/bnx2x.c b/drivers/net/bnx2x.c
index 8af142ccf373..de32b3fba322 100644
--- a/drivers/net/bnx2x.c
+++ b/drivers/net/bnx2x.c
@@ -63,8 +63,8 @@
63#include "bnx2x.h" 63#include "bnx2x.h"
64#include "bnx2x_init.h" 64#include "bnx2x_init.h"
65 65
66#define DRV_MODULE_VERSION "1.40.22" 66#define DRV_MODULE_VERSION "1.42.3"
67#define DRV_MODULE_RELDATE "2007/11/27" 67#define DRV_MODULE_RELDATE "2008/3/9"
68#define BNX2X_BC_VER 0x040200 68#define BNX2X_BC_VER 0x040200
69 69
70/* Time in jiffies before concluding the transmitter is hung. */ 70/* Time in jiffies before concluding the transmitter is hung. */
@@ -8008,38 +8008,6 @@ static int bnx2x_set_settings(struct net_device *dev, struct ethtool_cmd *cmd)
8008 cmd->duplex, cmd->port, cmd->phy_address, cmd->transceiver, 8008 cmd->duplex, cmd->port, cmd->phy_address, cmd->transceiver,
8009 cmd->autoneg, cmd->maxtxpkt, cmd->maxrxpkt); 8009 cmd->autoneg, cmd->maxtxpkt, cmd->maxrxpkt);
8010 8010
8011 switch (cmd->port) {
8012 case PORT_TP:
8013 if (!(bp->supported & SUPPORTED_TP)) {
8014 DP(NETIF_MSG_LINK, "TP not supported\n");
8015 return -EINVAL;
8016 }
8017
8018 if (bp->phy_flags & PHY_XGXS_FLAG) {
8019 bnx2x_link_reset(bp);
8020 bnx2x_link_settings_supported(bp, SWITCH_CFG_1G);
8021 bnx2x_phy_deassert(bp);
8022 }
8023 break;
8024
8025 case PORT_FIBRE:
8026 if (!(bp->supported & SUPPORTED_FIBRE)) {
8027 DP(NETIF_MSG_LINK, "FIBRE not supported\n");
8028 return -EINVAL;
8029 }
8030
8031 if (!(bp->phy_flags & PHY_XGXS_FLAG)) {
8032 bnx2x_link_reset(bp);
8033 bnx2x_link_settings_supported(bp, SWITCH_CFG_10G);
8034 bnx2x_phy_deassert(bp);
8035 }
8036 break;
8037
8038 default:
8039 DP(NETIF_MSG_LINK, "Unknown port type\n");
8040 return -EINVAL;
8041 }
8042
8043 if (cmd->autoneg == AUTONEG_ENABLE) { 8011 if (cmd->autoneg == AUTONEG_ENABLE) {
8044 if (!(bp->supported & SUPPORTED_Autoneg)) { 8012 if (!(bp->supported & SUPPORTED_Autoneg)) {
8045 DP(NETIF_MSG_LINK, "Aotoneg not supported\n"); 8013 DP(NETIF_MSG_LINK, "Aotoneg not supported\n");