USB: ftdi_sio: add vendor and product id for Bayer glucose meter serial converter cable
Attached patch adds USB vendor and product IDs for Bayer's USB to serial converter cable used by Bayer blood glucose meters. It seems to be a FT232RL based device and works without any problem with ftdi_sio driver when this patch is applied. See: http://winglucofacts.com/cables/ Signed-off-by: Marko Hänninen <bugitus@gmail.com> Cc: stable <stable@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/usb/serial/ftdi_sio.c1
-rw-r--r--drivers/usb/serial/ftdi_sio.h7
2 files changed, 8 insertions, 0 deletions
diff --git a/drivers/usb/serial/ftdi_sio.c b/drivers/usb/serial/ftdi_sio.c
index b574878c78b2..500087ea58a5 100644
--- a/drivers/usb/serial/ftdi_sio.c
+++ b/drivers/usb/serial/ftdi_sio.c
@@ -699,6 +699,7 @@ static struct usb_device_id id_table_combined [] = {
699 .driver_info = (kernel_ulong_t)&ftdi_jtag_quirk }, 699 .driver_info = (kernel_ulong_t)&ftdi_jtag_quirk },
700 { USB_DEVICE(LARSENBRUSGAARD_VID, LB_ALTITRACK_PID) }, 700 { USB_DEVICE(LARSENBRUSGAARD_VID, LB_ALTITRACK_PID) },
701 { USB_DEVICE(GN_OTOMETRICS_VID, AURICAL_USB_PID) }, 701 { USB_DEVICE(GN_OTOMETRICS_VID, AURICAL_USB_PID) },
702 { USB_DEVICE(BAYER_VID, BAYER_CONTOUR_CABLE_PID) },
702 { }, /* Optional parameter entry */ 703 { }, /* Optional parameter entry */
703 { } /* Terminating entry */ 704 { } /* Terminating entry */
704}; 705};
diff --git a/drivers/usb/serial/ftdi_sio.h b/drivers/usb/serial/ftdi_sio.h
index 24dbd99e87d7..f203b2a51302 100644
--- a/drivers/usb/serial/ftdi_sio.h
+++ b/drivers/usb/serial/ftdi_sio.h
@@ -954,6 +954,13 @@
954#define AURICAL_USB_PID 0x0010 /* Aurical USB Audiometer */ 954#define AURICAL_USB_PID 0x0010 /* Aurical USB Audiometer */
955 955
956/* 956/*
957 * Bayer Ascensia Contour blood glucose meter USB-converter cable.
958 * http://winglucofacts.com/cables/
959 */
960#define BAYER_VID 0x1A79
961#define BAYER_CONTOUR_CABLE_PID 0x6001
962
963/*