diff options
author | Andreas Herrmann <andreas.herrmann3@amd.com> | 2010-07-09 10:22:47 -0400 |
---|---|---|
committer | Jean Delvare <khali@linux-fr.org> | 2010-07-09 10:22:47 -0400 |
commit | d535bad90dad4eb42ec6528043fcfb53627d4f89 (patch) | |
tree | 0ec65cd980bcfa0e859cdf4a43d583d331fd130f /drivers/hwmon | |
parent | e467e104bb7482170b79f516d2025e7cfcaaa733 (diff) |
hwmon: (k8temp) Fix temperature reporting for ASB1 processor revisions
Reported temperature for ASB1 CPUs is too high.
Add ASB1 CPU revisions (these are also non-desktop variants) to the
list of CPUs for which the temperature fixup is not required.
Example: (from LENOVO ThinkPad Edge 13, 01972NG, system was idle)
Current kernel reports
$ sensors
k8temp-pci-00c3
Adapter: PCI adapter
Core0 Temp: +74.0 C
Core0 Temp: +70.0 C
Core1 Temp: +69.0 C
Core1 Temp: +70.0 C
With this patch I have
$ sensors
k8temp-pci-00c3
Adapter: PCI adapter
Core0 Temp: +54.0 C
Core0 Temp: +51.0 C
Core1 Temp: +48.0 C
Core1 Temp: +49.0 C
Cc: stable@kernel.org [.32.x .33.x, .34.x]
Cc: Rudolf Marek <r.marek@assembler.cz>
Signed-off-by: Andreas Herrmann <andreas.herrmann3@amd.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'drivers/hwmon')
-rw-r--r-- | drivers/hwmon/k8temp.c | 10 |
1 files changed, 6 insertions, 4 deletions
diff --git a/drivers/hwmon/k8temp.c b/drivers/hwmon/k8temp.c index f26acdb11681..8bdf80d91598 100644 --- a/drivers/hwmon/k8temp.c +++ b/drivers/hwmon/k8temp.c | |||
@@ -180,11 +180,13 @@ static int __devinit k8temp_probe(struct pci_dev *pdev, | |||
180 | } | 180 | } |
181 | 181 | ||
182 | if ((model >= 0x69) && | 182 | if ((model >= 0x69) && |
183 | !(model == 0xc1 || model == 0x6c || model == 0x7c)) { | 183 | !(model == 0xc1 || model == 0x6c || model == 0x7c || |
184 | model == 0x6b || model == 0x6f || model == 0x7f)) { | ||
184 | /* | 185 | /* |
185 | * RevG desktop CPUs (i.e. no socket S1G1 parts) | 186 | * RevG desktop CPUs (i.e. no socket S1G1 or |
186 | * need additional offset, otherwise reported | 187 | * ASB1 parts) need additional offset, |
187 | * temperature is below ambient temperature | 188 | * otherwise reported temperature is below |
189 | * ambient temperature | ||
188 | */ | 190 | */ |
189 | data->temp_offset = 21000; | 191 | data->temp_offset = 21000; |
190 | } | 192 | } |