diff options
author | Tomasz Figa <tomasz.figa@gmail.com> | 2013-06-16 20:10:24 -0400 |
---|---|---|
committer | Tomasz Figa <tomasz.figa@gmail.com> | 2013-08-05 19:21:41 -0400 |
commit | ceea124103c6f00561491b45133be5ccefc8ea1d (patch) | |
tree | 1e6dbd59c3f6e82d6337567de108c9a64dc8cb2d /drivers/clocksource/cadence_ttc_timer.c | |
parent | e24154896e2f60b0c20bda492d662ad77ffa5c32 (diff) |
clocksource: samsung_pwm_timer: Correct definition of AUTORELOAD bit
PWM channel 4 has its autoreload bit located at different position. This
patch fixes the driver to account for that.
This fixes a problem with the clocksource hanging after it overflows because
it is not reloaded any more.
Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Tested-by: Heiko Stuebner <heiko@sntech.de>
Tested-by: Mark Brown <broonie@linaro.org>
Tested-by: Sylwester Nawrocki <sylvester.nawrocki@gmail.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Diffstat (limited to 'drivers/clocksource/cadence_ttc_timer.c')
0 files changed, 0 insertions, 0 deletions