[ACPI] fix passive cooling regression
Return logic was inverted. Going for changing the return value to not return zero as it is makes more sense regarding the naming of the function (cpu_has_cpufreq()). http://bugzilla.kernel.org/show_bug.cgi?id=3410 Signed-off-by: Thomas Renninger <trenn@suse.de> Signed-off-by: Len Brown <len.brown@intel.com>
Diffstat (limited to 'drivers/acpi/processor_thermal.c')
-rw-r--r--drivers/acpi/processor_thermal.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/acpi/processor_thermal.c b/drivers/acpi/processor_thermal.c
index f37584015324..dc9817cfb882 100644
--- a/drivers/acpi/processor_thermal.c
+++ b/drivers/acpi/processor_thermal.c
@@ -102,8 +102,8 @@ static int cpu_has_cpufreq(unsigned int cpu)
102{ 102{
103 struct cpufreq_policy policy; 103 struct cpufreq_policy policy;
104 if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu)) 104 if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu))
105 return -ENODEV; 105 return 0;
106 return 0; 106 return 1;