aboutsummaryrefslogtreecommitdiffstats
path: root/arch/sparc64/kernel/setup.c
diff options
context:
space:
mode:
authorEddie C. Dost <ecd@brainaid.de>2006-01-18 17:54:31 -0500
committerDavid S. Miller <davem@davemloft.net>2006-01-18 17:54:31 -0500
commitc126cf80d450a4d0aac3de7162d4c14b5c971b24 (patch)
treedfac36b98cd1ff6d05d2a15482c39c2ecedc5cb3 /arch/sparc64/kernel/setup.c
parentc07a8475ddcadb55b11379c35c9586971a9cedbf (diff)
[SPARC64]: Serial Console for E250 Patch
From: Eddie C. Dost <ecd@brainaid.de> I have the following patch for serial console over the RSC (remote system controller) on my E250 machine. It basically adds support for input-device=rsc and output-device=rsc from OBP, and allows 115200,8,n,1,- serial mode setting. Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'arch/sparc64/kernel/setup.c')
-rw-r--r--arch/sparc64/kernel/setup.c2
1 files changed, 2 insertions, 0 deletions
diff --git a/arch/sparc64/kernel/setup.c b/arch/sparc64/kernel/setup.c
index 250745896aee..054461e6946d 100644
--- a/arch/sparc64/kernel/setup.c
+++ b/arch/sparc64/kernel/setup.c
@@ -561,6 +561,8 @@ static int __init set_preferred_console(void)
561 serial_console = 1; 561 serial_console = 1;
562 } else if (idev == PROMDEV_ITTYB && odev == PROMDEV_OTTYB) { 562 } else if (idev == PROMDEV_ITTYB && odev == PROMDEV_OTTYB) {
563 serial_console = 2; 563 serial_console = 2;
564 } else if (idev == PROMDEV_IRSC && odev == PROMDEV_ORSC) {
565 serial_console = 3;
564 } else { 566 } else {
565 prom_printf("Inconsistent console: " 567 prom_printf("Inconsistent console: "
566 "input %d, output %d\n", 568 "input %d, output %d\n",