diff options
author | David Daney <ddaney@caviumnetworks.com> | 2009-07-14 21:16:50 -0400 |
---|---|---|
committer | Ralf Baechle <ralf@linux-mips.org> | 2009-08-03 12:52:44 -0400 |
commit | 838c05705ef8c110037a713526bb18762db0a241 (patch) | |
tree | e1c8a533d0cbc11c4a7aaeb668dee12cefabc03c /arch/mips/pci | |
parent | 3e6e92183118d26d856e8efb549987164d1b49b4 (diff) |
MIPS: Octeon PCIe: Make hardware and software bus numbers match.
Some SiliconImage PCIe SATA controlers are not detected when the bus
numbers differ.
Signed-off-by: David Daney <ddaney@caviumnetworks.com>
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
Diffstat (limited to 'arch/mips/pci')
-rw-r--r-- | arch/mips/pci/pcie-octeon.c | 31 |
1 files changed, 17 insertions, 14 deletions
diff --git a/arch/mips/pci/pcie-octeon.c b/arch/mips/pci/pcie-octeon.c index 75262247f3e4..6aa5c542d52d 100644 --- a/arch/mips/pci/pcie-octeon.c +++ b/arch/mips/pci/pcie-octeon.c | |||
@@ -1040,19 +1040,29 @@ static inline int octeon_pcie_read_config(int pcie_port, struct pci_bus *bus, | |||
1040 | int bus_number = bus->number; | 1040 | int bus_number = bus->number; |
1041 | 1041 | ||
1042 | /* | 1042 | /* |
1043 | * We need to force the bus number to be zero on the root | 1043 | * For the top level bus make sure our hardware bus number |
1044 | * bus. Linux numbers the 2nd root bus to start after all | 1044 | * matches the software one. |
1045 | * buses on root 0. | ||
1046 | */ | 1045 | */ |
1047 | if (bus->parent == NULL) | 1046 | if (bus->parent == NULL) { |
1048 | bus_number = 0; | 1047 | union cvmx_pciercx_cfg006 pciercx_cfg006; |
1048 | pciercx_cfg006.u32 = cvmx_pcie_cfgx_read(pcie_port, | ||
1049 | CVMX_PCIERCX_CFG006(pcie_port)); | ||
1050 | if (pciercx_cfg006.s.pbnum != bus_number) { | ||
1051 | pciercx_cfg006.s.pbnum = bus_number; | ||
1052 | pciercx_cfg006.s.sbnum = bus_number; | ||
1053 | pciercx_cfg006.s.subbnum = bus_number; | ||
1054 | cvmx_pcie_cfgx_write(pcie_port, | ||
1055 | CVMX_PCIERCX_CFG006(pcie_port), | ||
1056 | pciercx_cfg006.u32); | ||
1057 | } | ||
1058 | } | ||
1049 | 1059 | ||
1050 | /* | 1060 | /* |
1051 | * PCIe only has a single device connected to Octeon. It is | 1061 | * PCIe only has a single device connected to Octeon. It is |
1052 | * always device ID 0. Don't bother doing reads for other | 1062 | * always device ID 0. Don't bother doing reads for other |
1053 | * device IDs on the first segment. | 1063 | * device IDs on the first segment. |
1054 | */ | 1064 | */ |
1055 | if ((bus_number == 0) && (devfn >> 3 != 0)) | 1065 | if ((bus->parent == NULL) && (devfn >> 3 != 0)) |
1056 | return PCIBIOS_FUNC_NOT_SUPPORTED; | 1066 | return PCIBIOS_FUNC_NOT_SUPPORTED; |
1057 | 1067 | ||
1058 | /* | 1068 | /* |
@@ -1070,7 +1080,7 @@ static inline int octeon_pcie_read_config(int pcie_port, struct pci_bus *bus, | |||
1070 | * bridge only respondes to device ID 0, function | 1080 | * bridge only respondes to device ID 0, function |
1071 | * 0-1 | 1081 | * 0-1 |
1072 | */ | 1082 | */ |
1073 | if ((bus_number == 0) && (devfn >= 2)) | 1083 | if ((bus->parent == NULL) && (devfn >= 2)) |
1074 | return PCIBIOS_FUNC_NOT_SUPPORTED; | 1084 | return PCIBIOS_FUNC_NOT_SUPPORTED; |
1075 | /* | 1085 | /* |
1076 | * The PCI-X slots are device ID 2,3. Choose one of | 1086 | * The PCI-X slots are device ID 2,3. Choose one of |
@@ -1167,13 +1177,6 @@ static inline int octeon_pcie_write_config(int pcie_port, struct pci_bus *bus, | |||
1167 | int size, u32 val) | 1177 | int size, u32 val) |
1168 | { | 1178 | { |
1169 | int bus_number = bus->number; | 1179 | int bus_number = bus->number; |
1170 | /* | ||
1171 | * We need to force the bus number to be zero on the root | ||
1172 | * bus. Linux numbers the 2nd root bus to start after all | ||
1173 | * busses on root 0. | ||
1174 | */ | ||
1175 | if (bus->parent == NULL) | ||
1176 | bus_number = 0; | ||
1177 | 1180 | ||
1178 | switch (size) { | 1181 | switch (size) { |
1179 | case 4: | 1182 | case 4: |