diff options
author | Ralf Baechle <ralf@linux-mips.org> | 2007-11-11 12:33:55 -0500 |
---|---|---|
committer | Ralf Baechle <ralf@linux-mips.org> | 2007-11-15 18:21:50 -0500 |
commit | 8dfa741f146b39eb59ef2094e03f47079ca99eb0 (patch) | |
tree | 823c790dff8619a3671c1a8a19671e020b9b4e2d /arch/mips/au1000 | |
parent | 622477533d3dc24845c847f386533f3c0e6a1be6 (diff) |
[MIPS] Sibyte: Stop timers before programming next even.
We have no guarantee by the generic time code that the timer is stopped
when the ->next_event method is called. Modifying the Timer Initial Count
register while the timer is enabled has UNPREDICTABLE effect according to
the BCM1250/BCM1125/BCM1125H User Manual. So stop the timer before
reprogramming.
This is a paranoia fix; no ill effects have been observed previously.
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
Diffstat (limited to 'arch/mips/au1000')
0 files changed, 0 insertions, 0 deletions