aboutsummaryrefslogtreecommitdiffstats
path: root/arch/arm/mach-s3c2410/Kconfig
diff options
context:
space:
mode:
authorBen Dooks <ben-linux@fluff.org>2006-12-19 17:46:17 -0500
committerRussell King <rmk+kernel@arm.linux.org.uk>2006-12-19 17:54:53 -0500
commit618b20a13e9ef4ed1d16f1ab94ccce8e4f55f9d9 (patch)
treeb8a603601694803e563bcf953e6b7b69089255d8 /arch/arm/mach-s3c2410/Kconfig
parent2d4ecdf5387a386588ae32e65f14c3c2569d9ef3 (diff)
[ARM] 4062/1: S3C24XX: Anubis and Osiris shuld have CONFIG_PM_SIMTEC
Both CONFIG_MACH_OSIRIS and CONFIG_MACH_ANUBIS should select CONFIG_PM_SIMTEC. This patch moves the selection of CONFIG_PM_SIMTEC to the machines that require it, as currently done with other machines in the S3C2410 architecture. Signed-off-by: Ben Dooks <ben-linux@fluff.org> Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
Diffstat (limited to 'arch/arm/mach-s3c2410/Kconfig')
-rw-r--r--arch/arm/mach-s3c2410/Kconfig10
1 files changed, 8 insertions, 2 deletions
diff --git a/arch/arm/mach-s3c2410/Kconfig b/arch/arm/mach-s3c2410/Kconfig
index 9ac6b5d1fa9b..eb4ec411312b 100644
--- a/arch/arm/mach-s3c2410/Kconfig
+++ b/arch/arm/mach-s3c2410/Kconfig
@@ -5,6 +5,7 @@ menu "S3C24XX Implementations"
5config MACH_AML_M5900 5config MACH_AML_M5900
6 bool "AML M5900 Series" 6 bool "AML M5900 Series"
7 select CPU_S3C2410 7 select CPU_S3C2410
8 select PM_SIMTEC if PM
8 help 9 help
9 Say Y here if you are using the American Microsystems M5900 Series 10 Say Y here if you are using the American Microsystems M5900 Series
10 <http://www.amltd.com> 11 <http://www.amltd.com>
@@ -12,6 +13,7 @@ config MACH_AML_M5900
12config MACH_ANUBIS 13config MACH_ANUBIS
13 bool "Simtec Electronics ANUBIS" 14 bool "Simtec Electronics ANUBIS"
14 select CPU_S3C2440 15 select CPU_S3C2440
16 select PM_SIMTEC if PM
15 help 17 help
16 Say Y here if you are using the Simtec Electronics ANUBIS 18 Say Y here if you are using the Simtec Electronics ANUBIS
17 development system 19 development system
@@ -19,6 +21,7 @@ config MACH_ANUBIS
19config MACH_OSIRIS 21config MACH_OSIRIS
20 bool "Simtec IM2440D20 (OSIRIS) module" 22 bool "Simtec IM2440D20 (OSIRIS) module"
21 select CPU_S3C2440 23 select CPU_S3C2440
24 select PM_SIMTEC if PM
22 help 25 help
23 Say Y here if you are using the Simtec IM2440D20 module, also 26 Say Y here if you are using the Simtec IM2440D20 module, also
24 known as the Osiris. 27 known as the Osiris.
@@ -26,6 +29,7 @@ config MACH_OSIRIS
26config ARCH_BAST 29config ARCH_BAST
27 bool "Simtec Electronics BAST (EB2410ITX)" 30 bool "Simtec Electronics BAST (EB2410ITX)"
28 select CPU_S3C2410 31 select CPU_S3C2410
32 select PM_SIMTEC if PM
29 select ISA 33 select ISA
30 help 34 help
31 Say Y here if you are using the Simtec Electronics EB2410ITX 35 Say Y here if you are using the Simtec Electronics EB2410ITX
@@ -111,6 +115,7 @@ config MACH_SMDK2413
111 115
112config MACH_VR1000 116config MACH_VR1000
113 bool "Thorcom VR1000" 117 bool "Thorcom VR1000"
118 select PM_SIMTEC if PM
114 select CPU_S3C2410 119 select CPU_S3C2410
115 help 120 help
116 Say Y here if you are using the Thorcom VR1000 board. 121 Say Y here if you are using the Thorcom VR1000 board.
@@ -297,8 +302,9 @@ config S3C2410_PM_CHECK_CHUNKSIZE
297 302
298config PM_SIMTEC 303config PM_SIMTEC
299 bool 304 bool
300 depends on PM && (ARCH_BAST || MACH_VR1000 || MACH_AML_M5900) 305 help
301 default y 306 Common power management code for systems that are
307 compatible with the Simtec style of power management
302 308
303config S3C2410_LOWLEVEL_UART_PORT 309config S3C2410_LOWLEVEL_UART_PORT
304 int "S3C2410 UART to use for low-level messages" 310 int "S3C2410 UART to use for low-level messages"