diff options
author | Roland Stigge <stigge@antcom.de> | 2011-01-09 09:31:39 -0500 |
---|---|---|
committer | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-01-09 12:10:10 -0500 |
commit | 6099469805c24af14250e182bb9ca082b8a6b716 (patch) | |
tree | 9b08dd1a10ff89f2557575f5bf95b07babf92beb /Documentation | |
parent | 430400b86304ea729ba10f2966a8af67da60a37f (diff) |
hwmon: Support for Dallas Semiconductor DS620
Driver for Dallas Semiconductor DS620 temperature sensor and thermostat
Signed-off-by: Roland Stigge <stigge@antcom.de>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/hwmon/ds620 | 34 |
1 files changed, 34 insertions, 0 deletions
diff --git a/Documentation/hwmon/ds620 b/Documentation/hwmon/ds620 new file mode 100644 index 000000000000..1fbe3cd916cc --- /dev/null +++ b/Documentation/hwmon/ds620 | |||
@@ -0,0 +1,34 @@ | |||
1 | Kernel driver ds620 | ||
2 | =================== | ||
3 | |||
4 | Supported chips: | ||
5 | * Dallas Semiconductor DS620 | ||
6 | Prefix: 'ds620' | ||
7 | Datasheet: Publicly available at the Dallas Semiconductor website | ||
8 | http://www.dalsemi.com/ | ||
9 | |||
10 | Authors: | ||
11 | Roland Stigge <stigge@antcom.de> | ||
12 | based on ds1621.c by | ||
13 | Christian W. Zuckschwerdt <zany@triq.net> | ||
14 | |||
15 | Description | ||
16 | ----------- | ||
17 | |||
18 | The DS620 is a (one instance) digital thermometer and thermostat. It has both | ||
19 | high and low temperature limits which can be user defined (i.e. programmed | ||
20 | into non-volatile on-chip registers). Temperature range is -55 degree Celsius | ||
21 | to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value | ||
22 | returned via sysfs displays post decimal positions. | ||
23 | |||
24 | The thermostat function works as follows: When configured via platform_data | ||
25 | (struct ds620_platform_data) .pomode == 0 (default), the thermostat output pin | ||
26 | PO is always low. If .pomode == 1, the thermostat is in PO_LOW mode. I.e., the | ||
27 | output pin PO becomes active when the temperature falls below temp1_min and | ||
28 | stays active until the temperature goes above temp1_max. | ||
29 | |||
30 | Likewise, with .pomode == 2, the thermostat is in PO_HIGH mode. I.e., the PO | ||
31 | output pin becomes active when the temperature goes above temp1_max and stays | ||
32 | active until the temperature falls below temp1_min. | ||
33 | |||
34 | The PO output pin of the DS620 operates active-low. | ||