diff options
author | Gong Jun <jgong@winbond.com> | 2007-01-18 16:14:24 -0500 |
---|---|---|
committer | Jean Delvare <khali@arrakis.delvare> | 2007-01-18 16:14:24 -0500 |
commit | 46bed4dfe5f95f1fc8f68ead592a7e295bbbe01e (patch) | |
tree | 9595db3fd526ac8d3e2e54be8fd88dd3f44cf245 /Documentation | |
parent | 9fab2d8b75a4084e91f1dcb4e55368406fe53010 (diff) |
hwmon/w83793: Ignore disabled temperature channels
Ignore the temperature readings when its channel is disabled,
ignore AMDSI readings.
Signed-off-by: Gong Jun <jgong@winbond.com>
Signed-off-by: Rudolf Marek <r.marek@assembler.cz>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/hwmon/w83793 | 8 |
1 files changed, 2 insertions, 6 deletions
diff --git a/Documentation/hwmon/w83793 b/Documentation/hwmon/w83793 index 45e5408340e0..51171a83165b 100644 --- a/Documentation/hwmon/w83793 +++ b/Documentation/hwmon/w83793 | |||
@@ -45,18 +45,14 @@ This driver implements support for Winbond W83793G/W83793R chips. | |||
45 | temp5-6 have a 1 degree Celsiis resolution. | 45 | temp5-6 have a 1 degree Celsiis resolution. |
46 | 46 | ||
47 | * Temperature sensor types | 47 | * Temperature sensor types |
48 | Temp1-4 have 3 possible types. It can be read from (and written to) | 48 | Temp1-4 have 2 possible types. It can be read from (and written to) |
49 | temp[1-4]_type. | 49 | temp[1-4]_type. |
50 | - If the value of 0, the related temperature channel stops | ||
51 | monitoring. | ||
52 | - If the value is 3, it starts monitoring using a remote termal diode | 50 | - If the value is 3, it starts monitoring using a remote termal diode |
53 | (default). | 51 | (default). |
54 | - If the value is 5, it starts monitoring using the temperature sensor | ||
55 | in AMD CPU and get result by AMDSI. | ||
56 | - If the value is 6, it starts monitoring using the temperature sensor | 52 | - If the value is 6, it starts monitoring using the temperature sensor |
57 | in Intel CPU and get result by PECI. | 53 | in Intel CPU and get result by PECI. |
58 | Temp5-6 can be connected to external thermistors (value of | 54 | Temp5-6 can be connected to external thermistors (value of |
59 | temp[5-6]_type is 4). They can also be disabled (value is 0). | 55 | temp[5-6]_type is 4). |
60 | 56 | ||
61 | * Alarm mechanism | 57 | * Alarm mechanism |
62 | For voltage sensors, an alarm triggers if the measured value is below | 58 | For voltage sensors, an alarm triggers if the measured value is below |