diff options
author | Doug Warzecha <Douglas_Warzecha@dell.com> | 2005-09-06 18:17:15 -0400 |
---|---|---|
committer | Linus Torvalds <torvalds@g5.osdl.org> | 2005-09-07 19:57:27 -0400 |
commit | 90563ec4129f14d19f018240d1d3ff5c0e5e6392 (patch) | |
tree | 93a8c5c3a0c30e27dcb4ff7ed804d68257181fe0 /Documentation | |
parent | 6c54c28e69f2a374ad708fba37cbe1c5bb94e283 (diff) |
[PATCH] dcdbas: add Dell Systems Management Base Driver with sysfs support
This patch adds the Dell Systems Management Base Driver with sysfs support.
This driver has been tested with Dell OpenManage.
Signed-off-by: Doug Warzecha <Douglas_Warzecha@dell.com>
Cc: Greg KH <greg@kroah.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/dcdbas.txt | 91 |
1 files changed, 91 insertions, 0 deletions
diff --git a/Documentation/dcdbas.txt b/Documentation/dcdbas.txt new file mode 100644 index 000000000000..e1c52e2dc361 --- /dev/null +++ b/Documentation/dcdbas.txt | |||
@@ -0,0 +1,91 @@ | |||
1 | Overview | ||
2 | |||
3 | The Dell Systems Management Base Driver provides a sysfs interface for | ||
4 | systems management software such as Dell OpenManage to perform system | ||
5 | management interrupts and host control actions (system power cycle or | ||
6 | power off after OS shutdown) on certain Dell systems. | ||
7 | |||
8 | Dell OpenManage requires this driver on the following Dell PowerEdge systems: | ||
9 | 300, 1300, 1400, 400SC, 500SC, 1500SC, 1550, 600SC, 1600SC, 650, 1655MC, | ||
10 | 700, and 750. Other Dell software such as the open source libsmbios project | ||
11 | is expected to make use of this driver, and it may include the use of this | ||
12 | driver on other Dell systems. | ||
13 | |||
14 | The Dell libsmbios project aims towards providing access to as much BIOS | ||
15 | information as possible. See http://linux.dell.com/libsmbios/main/ for | ||
16 | more information about the libsmbios project. | ||
17 | |||
18 | |||
19 | System Management Interrupt | ||
20 | |||
21 | On some Dell systems, systems management software must access certain | ||
22 | management information via a system management interrupt (SMI). The SMI data | ||
23 | buffer must reside in 32-bit address space, and the physical address of the | ||
24 | buffer is required for the SMI. The driver maintains the memory required for | ||
25 | the SMI and provides a way for the application to generate the SMI. | ||
26 | The driver creates the following sysfs entries for systems management | ||
27 | software to perform these system management interrupts: | ||
28 | |||
29 | /sys/devices/platform/dcdbas/smi_data | ||
30 | /sys/devices/platform/dcdbas/smi_data_buf_phys_addr | ||
31 | /sys/devices/platform/dcdbas/smi_data_buf_size | ||
32 | /sys/devices/platform/dcdbas/smi_request | ||
33 | |||
34 | Systems management software must perform the following steps to execute | ||
35 | a SMI using this driver: | ||
36 | |||
37 | 1) Lock smi_data. | ||
38 | 2) Write system management command to smi_data. | ||
39 | 3) Write "1" to smi_request to generate a calling interface SMI or | ||
40 | "2" to generate a raw SMI. | ||
41 | 4) Read system management command response from smi_data. | ||
42 | 5) Unlock smi_data. | ||
43 | |||
44 | |||
45 | Host Control Action | ||
46 | |||
47 | Dell OpenManage supports a host control feature that allows the administrator | ||
48 | to perform a power cycle or power off of the system after the OS has finished | ||
49 | shutting down. On some Dell systems, this host control feature requires that | ||
50 | a driver perform a SMI after the OS has finished shutting down. | ||
51 | |||
52 | The driver creates the following sysfs entries for systems management software | ||
53 | to schedule the driver to perform a power cycle or power off host control | ||
54 | action after the system has finished shutting down: | ||
55 | |||
56 | /sys/devices/platform/dcdbas/host_control_action | ||
57 | /sys/devices/platform/dcdbas/host_control_smi_type | ||
58 | /sys/devices/platform/dcdbas/host_control_on_shutdown | ||
59 | |||
60 | Dell OpenManage performs the following steps to execute a power cycle or | ||
61 | power off host control action using this driver: | ||
62 | |||
63 | 1) Write host control action to be performed to host_control_action. | ||
64 | 2) Write type of SMI that driver needs to perform to host_control_smi_type. | ||
65 | 3) Write "1" to host_control_on_shutdown to enable host control action. | ||
66 | 4) Initiate OS shutdown. | ||
67 | (Driver will perform host control SMI when it is notified that the OS | ||
68 | has finished shutting down.) | ||
69 | |||
70 | |||
71 | Host Control SMI Type | ||
72 | |||
73 | The following table shows the value to write to host_control_smi_type to | ||
74 | perform a power cycle or power off host control action: | ||
75 | |||
76 | PowerEdge System Host Control SMI Type | ||
77 | ---------------- --------------------- | ||
78 | 300 HC_SMITYPE_TYPE1 | ||
79 | 1300 HC_SMITYPE_TYPE1 | ||
80 | 1400 HC_SMITYPE_TYPE2 | ||
81 | 500SC HC_SMITYPE_TYPE2 | ||
82 | 1500SC HC_SMITYPE_TYPE2 | ||
83 | 1550 HC_SMITYPE_TYPE2 | ||
84 | 600SC HC_SMITYPE_TYPE2 | ||
85 | 1600SC HC_SMITYPE_TYPE2 | ||
86 | 650 HC_SMITYPE_TYPE2 | ||
87 | 1655MC HC_SMITYPE_TYPE2 | ||
88 | 700 HC_SMITYPE_TYPE3 | ||
89 | 750 HC_SMITYPE_TYPE3 | ||
90 | |||
91 | |||