the generic thermal sysfs driver
The Generic Thermal sysfs driver for thermal management.
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Thomas Sujith <sujith.thomas@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
Diffstat (limited to 'Documentation/thermal')
| -rw-r--r-- | Documentation/thermal/sysfs-api.txt | 246 |
1 files changed, 246 insertions, 0 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt new file mode 100644 index 000000000000..5776e090359d --- /dev/null +++ b/Documentation/thermal/sysfs-api.txt | |||
| @@ -0,0 +1,246 @@ | |||
| 1 | Generic Thermal Sysfs driver How To | ||
| 2 | ========================= | ||
| 3 | |||
| 4 | Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com> | ||
| 5 | |||
| 6 | Updated: 2 January 2008 | ||
| 7 | |||
| 8 | Copyright (c) 2008 Intel Corporation | ||
| 9 | |||
| 10 | |||
| 11 | 0. Introduction | ||
| 12 | |||
| 13 | The generic thermal sysfs provides a set of interfaces for thermal zone devices (sensors) | ||
| 14 | and thermal cooling devices (fan, processor...) to register with the thermal management | ||
| 15 | solution and to be a part of it. | ||
| 16 | |||
| 17 | This how-to focusses on enabling new thermal zone and cooling devices to participate | ||
| 18 | in thermal management. | ||
| 19 | This solution is platform independent and any type of thermal zone devices and | ||
| 20 | cooling devices should be able to make use of the infrastructure. | ||
| 21 | |||
| 22 | The main task of the thermal sysfs driver is to expose thermal zone attributes as well | ||
| 23 | as cooling device attributes to the user space. | ||
| 24 | An intelligent thermal management application can make decisions based on inputs | ||
| 25 | from thermal zone attributes (the current temperature and trip point temperature) | ||
| 26 | and throttle appropriate devices. | ||
| 27 | |||
| 28 | [0-*] denotes any positive number starting from 0 | ||
| 29 | [1-*] denotes any positive number starting from 1 | ||
| 30 | |||
| 31 | 1. thermal sysfs driver interface functions | ||
| 32 | |||
| 33 | 1.1 thermal zone device interface | ||
| 34 | 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name, int trips, | ||
| 35 | void *devdata, struct thermal_zone_device_ops *ops) | ||
| 36 | |||
| 37 | This interface function adds a new thermal zone device (sensor) to | ||
| 38 | /sys/class/thermal folder as thermal_zone[0-*]. | ||
| 39 | It tries to bind all the thermal cooling devices registered at the same time. | ||
| 40 | |||
| 41 | name: the thermal zone name. | ||
| 42 | trips: the total number of trip points this thermal zone supports. | ||
| 43 | devdata: device private data | ||
| 44 | ops: thermal zone device callbacks. | ||
| 45 | .bind: bind the thermal zone device with a thermal cooling device. | ||
| 46 | .unbind: unbing the thermal zone device with a thermal cooling device. | ||
| 47 | .get_temp: get the current temperature of the thermal zone. | ||
| 48 | .get_mode: get the current mode (user/kernel) of the thermal zone. | ||
| 49 | "kernel" means thermal management is done in kernel. | ||
| 50 | "user" will prevent kernel thermal driver actions upon trip points | ||
| 51 | so that user applications can take charge of thermal management. | ||
| 52 | .set_mode: set the mode (user/kernel) of the thermal zone. | ||
| 53 | .get_trip_type: get the type of certain trip point. | ||
| 54 | .get_trip_temp: get the temperature above which the certain trip point | ||
| 55 | will be fired. | ||
| 56 | |||
| 57 | 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz) | ||
| 58 | |||
| 59 | This interface function removes the thermal zone device. | ||
| 60 | It deletes the corresponding entry form /sys/class/thermal folder and unbind all | ||
| 61 | the thermal cooling devices it uses. | ||
| 62 | |||
| 63 | 1.2 thermal cooling device interface | ||
| 64 | 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name, | ||
| 65 | void *devdata, struct thermal_cooling_device_ops *) | ||
| 66 | |||
| 67 | This interface function adds a new thermal cooling device (fan/processor/...) to | ||
| 68 | /sys/class/thermal/ folder as cooling_device[0-*]. | ||
| 69 | It tries to bind itself to all the thermal zone devices register at the same time. | ||
| 70 | name: the cooling device name. | ||
| 71 | devdata: device private data. | ||
| 72 | ops: thermal cooling devices callbacks. | ||
| 73 | .get_max_state: get the Maximum throttle state of the cooling device. | ||
| 74 | .get_cur_state: get the Current throttle state of the cooling device. | ||
| 75 | .set_cur_state: set the Current throttle state of the cooling device. | ||
| 76 | |||
| 77 | 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev) | ||
| 78 | |||
| 79 | This interface function remove the thermal cooling device. | ||
| 80 | It deletes the corresponding entry form /sys/class/thermal folder and unbind | ||
| 81 | itself from all the thermal zone devices using it. | ||
| 82 | |||
| 83 | 1.3 interface for binding a thermal zone device with a thermal cooling device | ||
| 84 | 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, | ||
| 85 | int trip, struct thermal_cooling_device *cdev); | ||
| 86 | |||
| 87 | This interface function bind a thermal cooling device to the certain trip point | ||
| 88 | of a thermal zone device. | ||
| 89 | This function is usually called in the thermal zone device .bind callback. | ||
| 90 | tz: the thermal zone device | ||
| 91 | cdev: thermal cooling device | ||
| 92 | trip: indicates which trip point the cooling devices is associated with | ||
| 93 | in this thermal zone. | ||
| 94 | |||
| 95 | 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz, | ||
| 96 | int trip, struct thermal_cooling_device *cdev); | ||
| 97 | |||
| 98 | This interface function unbind a thermal cooling device from the certain trip point | ||
| 99 | of a thermal zone device. | ||
| 100 | This function is usually called in the thermal zone device .unbind callback. | ||
| 101 | tz: the thermal zone device | ||
| 102 | cdev: thermal cooling device | ||
| 103 | trip: indicates which trip point the cooling devices is associated with | ||
| 104 | in this thermal zone. | ||
| 105 | |||
| 106 | 2. sysfs attributes structure | ||
| 107 | |||
| 108 | RO read only value | ||
| 109 | RW read/write value | ||
| 110 | |||
| 111 | All thermal sysfs attributes will be represented under /sys/class/thermal | ||
| 112 | /sys/class/thermal/ | ||
| 113 | |||
| 114 | Thermal zone device sys I/F, created once it's registered: | ||
| 115 | |thermal_zone[0-*]: | ||
| 116 | |-----type: Type of the thermal zone | ||
| 117 | |-----temp: Current temperature | ||
| 118 | |-----mode: Working mode of the thermal zone | ||
| 119 | |-----trip_point_[0-*]_temp: Trip point temperature | ||
| 120 | |-----trip_point_[0-*]_type: Trip point type | ||
| 121 | |||
| 122 | Thermal cooling device sys I/F, created once it's registered: | ||
| 123 | |cooling_device[0-*]: | ||
| 124 | |-----type : Type of the cooling device(processor/fan/...) | ||
| 125 | |-----max_state: Maximum cooling state of the cooling device | ||
| 126 | |-----cur_state: Current cooling state of the cooling device | ||
| 127 | |||
| 128 | |||
| 129 | These two dynamic attributes are created/removed in pairs. | ||
| 130 | They represent the relationship between a thermal zone and its associated cooling device. | ||
| 131 | They are created/removed for each | ||
| 132 | thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device successful exection. | ||
| 133 | |||
| 134 | |thermal_zone[0-*] | ||
| 135 | |-----cdev[0-*]: The [0-*]th cooling device in the current thermal zone | ||
| 136 | |-----cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with | ||
| 137 | |||
| 138 | |||
| 139 | *************************** | ||
| 140 | * Thermal zone attributes * | ||
| 141 | *************************** | ||
| 142 | |||
| 143 | type Strings which represent the thermal zone type. | ||
| 144 | This is given by thermal zone driver as part of registration. | ||
| 145 | Eg: "ACPI thermal zone" indicates it's a ACPI thermal device | ||
| 146 | RO | ||
| 147 | Optional | ||
| 148 | |||
| 149 | temp Current temperature as reported by thermal zone (sensor) | ||
| 150 | Unit: degree celsius | ||
| 151 | RO | ||
| 152 | Required | ||
| 153 | |||
| 154 | mode One of the predifned values in [kernel, user] | ||
| 155 | This file gives information about the algorithm | ||
| 156 | that is currently managing the thermal zone. | ||
| 157 | It can be either default kernel based algorithm | ||
| 158 | or user space application. | ||
| 159 | RW | ||
| 160 | Optional | ||
| 161 | kernel = Thermal management in kernel thermal zone driver. | ||
| 162 | user = Preventing kernel thermal zone driver actions upon | ||
| 163 | trip points so that user application can take full | ||
| 164 | charge of the thermal management. | ||
| 165 | |||
| 166 | trip_point_[0-*]_temp The temperature above which trip point will be fired | ||
| 167 | Unit: degree celsius | ||
| 168 | RO | ||
| 169 | Optional | ||
| 170 | |||
| 171 | trip_point_[0-*]_type Strings which indicate the type of the trip point | ||
| 172 | Eg. it can be one of critical, hot, passive, | ||
| 173 | active[0-*] for ACPI thermal zone. | ||
| 174 | RO | ||
| 175 | Optional | ||
| 176 | |||
| 177 | cdev[0-*] Sysfs link to the thermal cooling device node where the sys I/F | ||
| 178 | for cooling device throttling control represents. | ||
| 179 | RO | ||
| 180 | Optional | ||
| 181 | |||
| 182 | cdev[0-*]_trip_point The trip point with which cdev[0-*] is assocated in this thermal zone | ||
| 183 | -1 means the cooling device is not associated with any trip point. | ||
| 184 | RO | ||
| 185 | Optional | ||
| 186 | |||
| 187 | ****************************** | ||
| 188 | * Cooling device attributes * | ||
| 189 | ****************************** | ||
| 190 | |||
| 191 | type String which represents the type of device | ||
| 192 | eg: For generic ACPI: this should be "Fan", | ||
| 193 | "Processor" or "LCD" | ||
| 194 | eg. For memory controller device on intel_menlow platform: | ||
| 195 | this should be "Memory controller" | ||
| 196 | RO | ||
| 197 | Optional | ||
| 198 | |||
| 199 | max_state The maximum permissible cooling state of this cooling device. | ||
| 200 | RO | ||
| 201 | Required | ||
| 202 | |||
| 203 | cur_state The current cooling state of this cooling device. | ||
| 204 | the value can any integer numbers between 0 and max_state, | ||
| 205 | cur_state == 0 means no cooling | ||
| 206 | cur_state == max_state means the maximum cooling. | ||
| 207 | RW | ||
| 208 | Required | ||
| 209 | |||
| 210 | 3. A simple implementation | ||
| 211 | |||
| 212 | ACPI thermal zone may support multiple trip points like critical/hot/passive/active. | ||
| 213 | If an ACPI thermal zone supports critical, passive, active[0] and active[1] at the same time, | ||
| 214 | it may register itself as a thermale_zone_device (thermal_zone1) with 4 trip points in all. | ||
| 215 | It has one processor and one fan, which are both registered as thermal_cooling_device. | ||
| 216 | If the processor is listed in _PSL method, and the fan is listed in _AL0 method, | ||
| 217 | the sys I/F structure will be built like this: | ||
| 218 | |||
| 219 | /sys/class/thermal: | ||
| 220 | |||
| 221 | |thermal_zone1: | ||
| 222 | |-----type: ACPI thermal zone | ||
| 223 | |-----temp: 37 | ||
| 224 | |-----mode: kernel | ||
| 225 | |-----trip_point_0_temp: 100 | ||
| 226 | |-----trip_point_0_type: critical | ||
| 227 | |-----trip_point_1_temp: 80 | ||
| 228 | |-----trip_point_1_type: passive | ||
| 229 | |-----trip_point_2_temp: 70 | ||
| 230 | |-----trip_point_2_type: active[0] | ||
| 231 | |-----trip_point_3_temp: 60 | ||
| 232 | |-----trip_point_3_type: active[1] | ||
| 233 | |-----cdev0: --->/sys/class/thermal/cooling_device0 | ||
| 234 | |-----cdev0_trip_point: 1 /* cdev0 can be used for passive */ | ||
| 235 | |-----cdev1: --->/sys/class/thermal/cooling_device3 | ||
| 236 | |-----cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/ | ||
| 237 | |||
| 238 | |cooling_device0: | ||
| 239 | |-----type: Processor | ||
| 240 | |-----max_state: 8 | ||
| 241 | |-----cur_state: 0 | ||
| 242 | |||
| 243 | |cooling_device3: | ||
| 244 | |-----type: Fan | ||
| 245 | |-----max_state: 2 | ||
| 246 | |-----cur_state: 0 | ||