diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2012-05-31 15:10:15 -0400 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2012-05-31 15:10:15 -0400 |
commit | 76f901eb4659779ecacd0e4eba49f55442daef53 (patch) | |
tree | 0761f03211ffdfc06216eabeb61b02ef6d598d3c /Documentation/power | |
parent | bd0e162d0312aa95e8b85ba883efddebf27be121 (diff) | |
parent | 96facd23e45e6d5020be135c8ab392ba9e044fa4 (diff) |
Merge tag 'for-v3.5' of git://git.infradead.org/battery-2.6
Pull battery updates from Anton Vorontsov:
"A bunch of fixes for v3.5, nothing extraordinary."
* tag 'for-v3.5' of git://git.infradead.org/battery-2.6: (27 commits)
smb347-charger: Include missing <linux/err.h>
smb347-charger: Clean up battery attributes
max17042_battery: Add support for max17047/50 chip
sbs-battery.c: Capacity attr = remaining relative capacity
isp1704_charger: Use after free on probe error
ds2781_battery: Use DS2781_PARAM_EEPROM_SIZE and DS2781_USER_EEPROM_SIZE
power_supply: Fix a typo in BATTERY_DS2781 Kconfig entry
charger-manager: Provide cm_notify_event function for in-kernel use
charger-manager: Poll battery health in normal state
smb347-charger: Convert to regmap API
smb347-charger: Move IRQ enabling to the end of probe
smb347-charger: Rename few functions to match better what they are doing
smb347-charger: Convert to use module_i2c_driver()
smb347_charger: Cleanup power supply registration code in probe
ab8500: Clean up probe routines
ab8500_fg: Harden platform data check
ab8500_btemp: Harden platform data check
ab8500_charger: Harden platform data check
MAINTAINERS: Fix 'F' entry for the power supply class
max17042_battery: Handle irq request failure case
...
Diffstat (limited to 'Documentation/power')
-rw-r--r-- | Documentation/power/charger-manager.txt | 41 | ||||
-rw-r--r-- | Documentation/power/power_supply_class.txt | 2 |
2 files changed, 41 insertions, 2 deletions
diff --git a/Documentation/power/charger-manager.txt b/Documentation/power/charger-manager.txt index fdcca991df30..b4f7f4b23f64 100644 --- a/Documentation/power/charger-manager.txt +++ b/Documentation/power/charger-manager.txt | |||
@@ -44,6 +44,16 @@ Charger Manager supports the following: | |||
44 | Normally, the platform will need to resume and suspend some devices | 44 | Normally, the platform will need to resume and suspend some devices |
45 | that are used by Charger Manager. | 45 | that are used by Charger Manager. |
46 | 46 | ||
47 | * Support for premature full-battery event handling | ||
48 | If the battery voltage drops by "fullbatt_vchkdrop_uV" after | ||
49 | "fullbatt_vchkdrop_ms" from the full-battery event, the framework | ||
50 | restarts charging. This check is also performed while suspended by | ||
51 | setting wakeup time accordingly and using suspend_again. | ||
52 | |||
53 | * Support for uevent-notify | ||
54 | With the charger-related events, the device sends | ||
55 | notification to users with UEVENT. | ||
56 | |||
47 | 2. Global Charger-Manager Data related with suspend_again | 57 | 2. Global Charger-Manager Data related with suspend_again |
48 | ======================================================== | 58 | ======================================================== |
49 | In order to setup Charger Manager with suspend-again feature | 59 | In order to setup Charger Manager with suspend-again feature |
@@ -55,7 +65,7 @@ if there are multiple batteries. If there are multiple batteries, the | |||
55 | multiple instances of Charger Manager share the same charger_global_desc | 65 | multiple instances of Charger Manager share the same charger_global_desc |
56 | and it will manage in-suspend monitoring for all instances of Charger Manager. | 66 | and it will manage in-suspend monitoring for all instances of Charger Manager. |
57 | 67 | ||
58 | The user needs to provide all the two entries properly in order to activate | 68 | The user needs to provide all the three entries properly in order to activate |
59 | in-suspend monitoring: | 69 | in-suspend monitoring: |
60 | 70 | ||
61 | struct charger_global_desc { | 71 | struct charger_global_desc { |
@@ -74,6 +84,11 @@ bool (*rtc_only_wakeup)(void); | |||
74 | same struct. If there is any other wakeup source triggered the | 84 | same struct. If there is any other wakeup source triggered the |
75 | wakeup, it should return false. If the "rtc" is the only wakeup | 85 | wakeup, it should return false. If the "rtc" is the only wakeup |
76 | reason, it should return true. | 86 | reason, it should return true. |
87 | |||
88 | bool assume_timer_stops_in_suspend; | ||
89 | : if true, Charger Manager assumes that | ||
90 | the timer (CM uses jiffies as timer) stops during suspend. Then, CM | ||
91 | assumes that the suspend-duration is same as the alarm length. | ||
77 | }; | 92 | }; |
78 | 93 | ||
79 | 3. How to setup suspend_again | 94 | 3. How to setup suspend_again |
@@ -111,6 +126,16 @@ enum polling_modes polling_mode; | |||
111 | CM_POLL_CHARGING_ONLY: poll this battery if and only if the | 126 | CM_POLL_CHARGING_ONLY: poll this battery if and only if the |
112 | battery is being charged. | 127 | battery is being charged. |
113 | 128 | ||
129 | unsigned int fullbatt_vchkdrop_ms; | ||
130 | unsigned int fullbatt_vchkdrop_uV; | ||
131 | : If both have non-zero values, Charger Manager will check the | ||
132 | battery voltage drop fullbatt_vchkdrop_ms after the battery is fully | ||
133 | charged. If the voltage drop is over fullbatt_vchkdrop_uV, Charger | ||
134 | Manager will try to recharge the battery by disabling and enabling | ||
135 | chargers. Recharge with voltage drop condition only (without delay | ||
136 | condition) is needed to be implemented with hardware interrupts from | ||
137 | fuel gauges or charger devices/chips. | ||
138 | |||
114 | unsigned int fullbatt_uV; | 139 | unsigned int fullbatt_uV; |
115 | : If specified with a non-zero value, Charger Manager assumes | 140 | : If specified with a non-zero value, Charger Manager assumes |
116 | that the battery is full (capacity = 100) if the battery is not being | 141 | that the battery is full (capacity = 100) if the battery is not being |
@@ -122,6 +147,8 @@ unsigned int polling_interval_ms; | |||
122 | this battery every polling_interval_ms or more frequently. | 147 | this battery every polling_interval_ms or more frequently. |
123 | 148 | ||
124 | enum data_source battery_present; | 149 | enum data_source battery_present; |
150 | : CM_BATTERY_PRESENT: assume that the battery exists. | ||
151 | CM_NO_BATTERY: assume that the battery does not exists. | ||
125 | CM_FUEL_GAUGE: get battery presence information from fuel gauge. | 152 | CM_FUEL_GAUGE: get battery presence information from fuel gauge. |
126 | CM_CHARGER_STAT: get battery presence from chargers. | 153 | CM_CHARGER_STAT: get battery presence from chargers. |
127 | 154 | ||
@@ -151,7 +178,17 @@ bool measure_battery_temp; | |||
151 | the value of measure_battery_temp. | 178 | the value of measure_battery_temp. |
152 | }; | 179 | }; |
153 | 180 | ||
154 | 5. Other Considerations | 181 | 5. Notify Charger-Manager of charger events: cm_notify_event() |
182 | ========================================================= | ||
183 | If there is an charger event is required to notify | ||
184 | Charger Manager, a charger device driver that triggers the event can call | ||
185 | cm_notify_event(psy, type, msg) to notify the corresponding Charger Manager. | ||
186 | In the function, psy is the charger driver's power_supply pointer, which is | ||
187 | associated with Charger-Manager. The parameter "type" | ||
188 | is the same as irq's type (enum cm_event_types). The event message "msg" is | ||
189 | optional and is effective only if the event type is "UNDESCRIBED" or "OTHERS". | ||
190 | |||
191 | 6. Other Considerations | ||
155 | ======================= | 192 | ======================= |
156 | 193 | ||
157 | At the charger/battery-related events such as battery-pulled-out, | 194 | At the charger/battery-related events such as battery-pulled-out, |
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index 9f16c5178b66..211831d4095f 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt | |||
@@ -84,6 +84,8 @@ are already charged or discharging, 'n/a' can be displayed (or | |||
84 | HEALTH - represents health of the battery, values corresponds to | 84 | HEALTH - represents health of the battery, values corresponds to |
85 | POWER_SUPPLY_HEALTH_*, defined in battery.h. | 85 | POWER_SUPPLY_HEALTH_*, defined in battery.h. |
86 | 86 | ||
87 | VOLTAGE_OCV - open circuit voltage of the battery. | ||
88 | |||
87 | VOLTAGE_MAX_DESIGN, VOLTAGE_MIN_DESIGN - design values for maximal and | 89 | VOLTAGE_MAX_DESIGN, VOLTAGE_MIN_DESIGN - design values for maximal and |
88 | minimal power supply voltages. Maximal/minimal means values of voltages | 90 | minimal power supply voltages. Maximal/minimal means values of voltages |
89 | when battery considered "full"/"empty" at normal conditions. Yes, there is | 91 | when battery considered "full"/"empty" at normal conditions. Yes, there is |