hwmon: (max8688) Add support for peak attributes
Add support for voltage, current, and temperature peak (historic maximum)
attributes.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/max8688 | 6 |
1 files changed, 6 insertions, 0 deletions
diff --git a/Documentation/hwmon/max8688 b/Documentation/hwmon/max8688 index 0ddd3a412030..71ed10a3c94e 100644 --- a/Documentation/hwmon/max8688 +++ b/Documentation/hwmon/max8688 | |||
@@ -50,6 +50,8 @@ in1_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. | |||
50 | in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. | 50 | in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. |
51 | in1_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. | 51 | in1_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. |
52 | in1_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. | 52 | in1_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. |
53 | in1_highest Historical maximum voltage. | ||
54 | in1_reset_history Write any value to reset history. | ||
53 | 55 | ||
54 | curr1_label "iout1" | 56 | curr1_label "iout1" |
55 | curr1_input Measured current. From READ_IOUT register. | 57 | curr1_input Measured current. From READ_IOUT register. |
@@ -57,6 +59,8 @@ curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register. | |||
57 | curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. | 59 | curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. |
58 | curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register. | 60 | curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register. |
59 | curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. | 61 | curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. |
62 | curr1_highest Historical maximum current. | ||
63 | curr1_reset_history Write any value to reset history. | ||
60 | 64 | ||
61 | temp1_input Measured temperature. From READ_TEMPERATURE_1 register. | 65 | temp1_input Measured temperature. From READ_TEMPERATURE_1 register. |
62 | temp1_max Maximum temperature. From OT_WARN_LIMIT register. | 66 | temp1_max Maximum temperature. From OT_WARN_LIMIT register. |
@@ -67,3 +71,5 @@ temp1_max_alarm Chip temperature high alarm. Set by comparing | |||
67 | temp1_crit_alarm Chip temperature critical high alarm. Set by comparing | 71 | temp1_crit_alarm Chip temperature critical high alarm. Set by comparing |
68 | READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT | 72 | READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT |
69 | status is set. | 73 | status is set. |
74 | temp1_highest Historical maximum temperature. | ||
75 | temp1_reset_history Write any value to reset history. | ||