aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorJean Delvare <khali@linux-fr.org>2010-03-05 16:17:15 -0500
committerJean Delvare <khali@linux-fr.org>2010-03-05 16:17:15 -0500
commit53de33427fa3d7dd62cc5ec75ce0d4e6c6d602dd (patch)
tree82a1fd88a2d132b534fe3df3e2ea536c1b5099ae /Documentation/hwmon
parent95238364167edaf93ce2890e5f55326b63194851 (diff)
hwmon: (lm90) Add SMBus alert support
Tested successfully with an ADM1032 chip on its evaluation board. It should work fine with all other chips as well. At this point this is more of a proof-of-concept, we don't do anything terribly useful on SMBus alert: we simply log the event. But this could later evolve into libsensors signaling so that user-space applications can take an appropriate action. Signed-off-by: Jean Delvare <khali@linux-fr.org> Cc: David Brownell <dbrownell@users.sourceforge.net> Cc: Trent Piepho <tpiepho@freescale.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/lm9012
1 files changed, 12 insertions, 0 deletions
diff --git a/Documentation/hwmon/lm90 b/Documentation/hwmon/lm90
index 08106ad7089c..6a03dd4bcc94 100644
--- a/Documentation/hwmon/lm90
+++ b/Documentation/hwmon/lm90
@@ -173,6 +173,18 @@ The lm90 driver will not update its values more frequently than every
173other second; reading them more often will do no harm, but will return 173other second; reading them more often will do no harm, but will return
174'old' values. 174'old' values.
175 175
176SMBus Alert Support
177-------------------
178
179This driver has basic support for SMBus alert. When an alert is received,
180the status register is read and the faulty temperature channel is logged.
181
182The Analog Devices chips (ADM1032 and ADT7461) do not implement the SMBus
183alert protocol properly so additional care is needed: the ALERT output is
184disabled when an alert is received, and is re-enabled only when the alarm
185is gone. Otherwise the chip would block alerts from other chips in the bus
186as long as the alarm is active.
187
176PEC Support 188PEC Support
177----------- 189-----------
178 190