authorGong Jun <jgong@winbond.com>2007-01-18 16:14:24 -0500
committerJean Delvare <khali@arrakis.delvare>2007-01-18 16:14:24 -0500
commit46bed4dfe5f95f1fc8f68ead592a7e295bbbe01e (patch)
tree9595db3fd526ac8d3e2e54be8fd88dd3f44cf245 /Documentation/hwmon
parent9fab2d8b75a4084e91f1dcb4e55368406fe53010 (diff)
hwmon/w83793: Ignore disabled temperature channels
Ignore the temperature readings when its channel is disabled, ignore AMDSI readings. Signed-off-by: Gong Jun <jgong@winbond.com> Signed-off-by: Rudolf Marek <r.marek@assembler.cz> Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/w837938
1 files changed, 2 insertions, 6 deletions
diff --git a/Documentation/hwmon/w83793 b/Documentation/hwmon/w83793
index 45e5408340e0..51171a83165b 100644
--- a/Documentation/hwmon/w83793
+++ b/Documentation/hwmon/w83793
@@ -45,18 +45,14 @@ This driver implements support for Winbond W83793G/W83793R chips.
45 temp5-6 have a 1 degree Celsiis resolution. 45 temp5-6 have a 1 degree Celsiis resolution.
46 46
47* Temperature sensor types 47* Temperature sensor types
48 Temp1-4 have 3 possible types. It can be read from (and written to) 48 Temp1-4 have 2 possible types. It can be read from (and written to)
49 temp[1-4]_type. 49 temp[1-4]_type.
50 - If the value of 0, the related temperature channel stops
51 monitoring.
52 - If the value is 3, it starts monitoring using a remote termal diode 50 - If the value is 3, it starts monitoring using a remote termal diode
53 (default). 51 (default).
54 - If the value is 5, it starts monitoring using the temperature sensor
55 in AMD CPU and get result by AMDSI.
56 - If the value is 6, it starts monitoring using the temperature sensor 52 - If the value is 6, it starts monitoring using the temperature sensor
57 in Intel CPU and get result by PECI. 53 in Intel CPU and get result by PECI.
58 Temp5-6 can be connected to external thermistors (value of 54 Temp5-6 can be connected to external thermistors (value of
59 temp[5-6]_type is 4). They can also be disabled (value is 0). 55 temp[5-6]_type is 4).
60 56
61* Alarm mechanism 57* Alarm mechanism
62 For voltage sensors, an alarm triggers if the measured value is below 58 For voltage sensors, an alarm triggers if the measured value is below