aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorAlexander Stein <alexander.stein@systec-electronic.com>2011-06-28 11:11:23 -0400
committerGuenter Roeck <guenter.roeck@ericsson.com>2011-07-28 03:17:35 -0400
commitfffd80ccc1e6c7e5f13741e17a7d80582ae21fcc (patch)
tree6c3b9d74a4f1cc21a2f60ac022e115c833b8ba78 /Documentation/hwmon
parent2ef017935d698b1c7c7421a7ebe20579d8f904dd (diff)
hwmon: LM95245 driver
A hwmon driver for the National Semiconductor LM95245 dual temperature sensors chip. Signed-off-by: Alexander Stein <alexander.stein@systec-electronic.com> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/lm9524533
1 files changed, 33 insertions, 0 deletions
diff --git a/Documentation/hwmon/lm95245 b/Documentation/hwmon/lm95245
new file mode 100644
index 000000000000..cbd8aeab7124
--- /dev/null
+++ b/Documentation/hwmon/lm95245
@@ -0,0 +1,33 @@
1Kernel driver lm95245
2==================
3
4Supported chips:
5 * National Semiconductor LM95245
6 Addresses scanned: I2C 0x18, 0x19, 0x29, 0x4c, 0x4d
7 Datasheet: Publicly available at the National Semiconductor website
8 http://www.national.com/mpf/LM/LM95245.html
9
10
11Author: Alexander Stein <alexander.stein@systec-electronic.com>
12
13Description
14-----------
15
16The LM95245 is an 11-bit digital temperature sensor with a 2-wire System
17Management Bus (SMBus) interface and TruTherm technology that can monitor
18the temperature of a remote diode as well as its own temperature.
19The LM95245 can be used to very accurately monitor the temperature of
20external devices such as microprocessors.
21
22All temperature values are given in millidegrees Celsius. Local temperature
23is given within a range of -127 to +127.875 degrees. Remote temperatures are
24given within a range of -127 to +255 degrees. Resolution depends on
25temperature input and range.
26
27Each sensor has its own critical limit, but the hysteresis is common to all
28two channels.
29
30The lm95245 driver can change its update interval to a fixed set of values.
31It will round up to the next selectable interval. See the datasheet for exact
32values. Reading sensor values more often will do no harm, but will return
33'old' values.