aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/w83627ehf
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@g5.osdl.org>2006-10-18 20:52:27 -0400
committerLinus Torvalds <torvalds@g5.osdl.org>2006-10-18 20:52:27 -0400
commit64d9a39ec9ad074384b548c0cead89265c82e166 (patch)
tree5c0cdd72f41584d33e76e4a3c08eeb1960a0b5c7 /Documentation/hwmon/w83627ehf
parent17e6c600b2bc4f15dd5f9144ccb8b5c5211dd6e4 (diff)
parentbd452e6f178a559408c54c2b4ca29191b812d47f (diff)
Merge git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/hwmon-2.6
* git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/hwmon-2.6: hwmon: Fix debug messages in w83781d hwmon: Let w83781d and lm78 load again w83627ehf: Fix the detection of fan5 k8temp: Documentation update smsc47m1: List the SMSC LPC47M112 as supported hwmon: Fix documentation typos adm9240: Update Grant Coady's email address w83791d: Fix unchecked return status
Diffstat (limited to 'Documentation/hwmon/w83627ehf')
-rw-r--r--Documentation/hwmon/w83627ehf6
1 files changed, 3 insertions, 3 deletions
diff --git a/Documentation/hwmon/w83627ehf b/Documentation/hwmon/w83627ehf
index fae3b781d82d..caa610a297e8 100644
--- a/Documentation/hwmon/w83627ehf
+++ b/Documentation/hwmon/w83627ehf
@@ -26,7 +26,7 @@ fan control mode).
26Temperatures are measured in degrees Celsius and measurement resolution is 1 26Temperatures are measured in degrees Celsius and measurement resolution is 1
27degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when 27degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when
28the temperature gets higher than high limit; it stays on until the temperature 28the temperature gets higher than high limit; it stays on until the temperature
29falls below the Hysteresis value. 29falls below the hysteresis value.
30 30
31Fan rotation speeds are reported in RPM (rotations per minute). An alarm is 31Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
32triggered if the rotation speed has dropped below a programmable limit. Fan 32triggered if the rotation speed has dropped below a programmable limit. Fan
@@ -67,9 +67,9 @@ Thermal Cruise mode
67 67
68If the temperature is in the range defined by: 68If the temperature is in the range defined by:
69 69
70pwm[1-4]_target - set target temperature, unit millidegree Celcius 70pwm[1-4]_target - set target temperature, unit millidegree Celsius
71 (range 0 - 127000) 71 (range 0 - 127000)
72pwm[1-4]_tolerance - tolerance, unit millidegree Celcius (range 0 - 15000) 72pwm[1-4]_tolerance - tolerance, unit millidegree Celsius (range 0 - 15000)
73 73
74there are no changes to fan speed. Once the temperature leaves the interval, 74there are no changes to fan speed. Once the temperature leaves the interval,
75fan speed increases (temp is higher) or decreases if lower than desired. 75fan speed increases (temp is higher) or decreases if lower than desired.