hwmon: (max8688) Add support for peak attributes
Add support for voltage, current, and temperature peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation/hwmon/max8688')
-rw-r--r--Documentation/hwmon/max86886
1 files changed, 6 insertions, 0 deletions
diff --git a/Documentation/hwmon/max8688 b/Documentation/hwmon/max8688
index 0ddd3a412030..71ed10a3c94e 100644
--- a/Documentation/hwmon/max8688
+++ b/Documentation/hwmon/max8688
@@ -50,6 +50,8 @@ in1_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
50in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. 50in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
51in1_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. 51in1_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
52in1_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. 52in1_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
53in1_highest Historical maximum voltage.
54in1_reset_history Write any value to reset history.
53 55
54curr1_label "iout1" 56curr1_label "iout1"
55curr1_input Measured current. From READ_IOUT register. 57curr1_input Measured current. From READ_IOUT register.
@@ -57,6 +59,8 @@ curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register.
57curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. 59curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
58curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register. 60curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register.
59curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. 61curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
62curr1_highest Historical maximum current.
63curr1_reset_history Write any value to reset history.
60 64
61temp1_input Measured temperature. From READ_TEMPERATURE_1 register. 65temp1_input Measured temperature. From READ_TEMPERATURE_1 register.
62temp1_max Maximum temperature. From OT_WARN_LIMIT register. 66temp1_max Maximum temperature. From OT_WARN_LIMIT register.
@@ -67,3 +71,5 @@ temp1_max_alarm Chip temperature high alarm. Set by comparing
67temp1_crit_alarm Chip temperature critical high alarm. Set by comparing 71temp1_crit_alarm Chip temperature critical high alarm. Set by comparing
68 READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT 72 READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT
69 status is set. 73 status is set.
74temp1_highest Historical maximum temperature.
75temp1_reset_history Write any value to reset history.