aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/lm90
diff options
context:
space:
mode:
authorJean Delvare <khali@linux-fr.org>2008-10-17 11:51:09 -0400
committerJean Delvare <khali@mahadeva.delvare>2008-10-17 11:51:09 -0400
commitf65e17086fc141bee1592bbf6e709e9c7a43541b (patch)
tree165e6da0dc246a02907108316fe12c5d6af4d2e6 /Documentation/hwmon/lm90
parent6388a388ffb720f40fc8046c261252ea2be9c12f (diff)
hwmon: (lm90) Support the extra resolution bits of MAX6657
The Maxim MAX6657, MAX6658 and MAX6659 have extra resolution bits for the local temperature measurement. Let the lm90 driver read them and export them to user-space. Signed-off-by: Jean Delvare <khali@linux-fr.org> Acked-by: Martyn Welch <martyn.welch@gefanuc.com>
Diffstat (limited to 'Documentation/hwmon/lm90')
-rw-r--r--Documentation/hwmon/lm9010
1 files changed, 6 insertions, 4 deletions
diff --git a/Documentation/hwmon/lm90 b/Documentation/hwmon/lm90
index aa4a0ec20081..0b3e8bb7c1f0 100644
--- a/Documentation/hwmon/lm90
+++ b/Documentation/hwmon/lm90
@@ -86,9 +86,8 @@ family is that it features critical limits with hysteresis, and an
86increased resolution of the remote temperature measurement. 86increased resolution of the remote temperature measurement.
87 87
88The different chipsets of the family are not strictly identical, although 88The different chipsets of the family are not strictly identical, although
89very similar. This driver doesn't handle any specific feature for now, 89very similar. For reference, here comes a non-exhaustive list of specific
90with the exception of SMBus PEC. For reference, here comes a non-exhaustive 90features:
91list of specific features:
92 91
93LM90: 92LM90:
94 * Filter and alert configuration register at 0xBF. 93 * Filter and alert configuration register at 0xBF.
@@ -114,9 +113,11 @@ ADT7461:
114 * Lower resolution for remote temperature 113 * Lower resolution for remote temperature
115 114
116MAX6657 and MAX6658: 115MAX6657 and MAX6658:
116 * Better local resolution
117 * Remote sensor type selection 117 * Remote sensor type selection
118 118
119MAX6659: 119MAX6659:
120 * Better local resolution
120 * Selectable address 121 * Selectable address
121 * Second critical temperature limit 122 * Second critical temperature limit
122 * Remote sensor type selection 123 * Remote sensor type selection
@@ -127,7 +128,8 @@ MAX6680 and MAX6681:
127 128
128All temperature values are given in degrees Celsius. Resolution 129All temperature values are given in degrees Celsius. Resolution
129is 1.0 degree for the local temperature, 0.125 degree for the remote 130is 1.0 degree for the local temperature, 0.125 degree for the remote
130temperature. 131temperature, except for the MAX6657, MAX6658 and MAX6659 which have a
132resolution of 0.125 degree for both temperatures.
131 133
132Each sensor has its own high and low limits, plus a critical limit. 134Each sensor has its own high and low limits, plus a critical limit.
133Additionally, there is a relative hysteresis value common to both critical 135Additionally, there is a relative hysteresis value common to both critical